Bulk-fill Composites Compared to a Nanohybrid Composite in Class-II Cavities-A Two-year Follow-Up Study

被引:7
|
作者
Hoffmann, Lea [1 ]
Neuerer, Cornelia [1 ]
Heck, Katrin [1 ]
Kunzelmann, Karl-Heinz [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Operat Restorat Dent & Periodontol, Goethe Str 70, D-80336 Munich, Germany
来源
JOURNAL OF ADHESIVE DENTISTRY | 2021年 / 23卷 / 05期
关键词
bulk-fill; clinical examination; 2-year follow-up; FDI criteria; POLYMERIZATION SHRINKAGE; RESIN COMPOSITES; STRESS; KINETICS; CURE;
D O I
10.3290/j.jad.b2000185
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare different concepts of direct composite restorations in class-II cavities using bulk-fill composites and a conventional composite with different layer thicknesses in a clinical study over a period of 2 years. Materials and Methods: A low-viscosity (SDR), a high-viscosity bulk-fill (Tetric EvoCeram Bulk Fill) and a conventional nanohybrid composite (Tetric EvoCeram) were randomly assigned and placed in different layer thicknesses up to 4 mm in 160 class-II cavities in 94 patients. Restorations were clinically examined at baseline (n = 160), after 12 (n = 150) and 24 months (n = 148) and evaluated according to eight selected FDI criteria. In case of complete loss of the restoration or irreversible pulpitic symptoms, the restoration was rated as failure; repair was considered as relative failure. Results: The materials investigated showed no significant differences regarding the FDI scores and failure rate during the entire follow-up. After 12 months, 7 failures and after 24 months a total of 8 failures were observed. After 2 years, Tetric EvoCeram Bulk Fill with a 4-mm layer thickness and SDR in combination with Tetric EvoCeram Bulk Fill with a 2-mm layer thickness exhibited a non-significant tendency towards increased hypersensitivity (FDI score 5) as compared to the reference material Tetric EvoCeram with a 2-mm layer thickness (p = 0.051; Kruskal-Wallis test). Conclusion: The clinical stability of bulk-fill materials in layers up to 4 mm is comparable to nanohybrid composites after 2 years.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 50 条
  • [41] Microhardness and cervical microleakage of healthy and periodontally involved dentin at class II cavities restored with conventional and bulk-fill resin composites
    Moosavi, Horieh
    Majidinia, Sara
    Banihashem, Seyed Ali
    Giv, Mohammad Jafari
    Namdar, Fatemeh
    [J]. ANNALI DI STOMATOLOGIA, 2018, 9 (03) : 123 - 129
  • [42] A 3-year clinical evaluation of two composite resins in class-II cavities
    Rasmusson, CG
    Kohler, B
    Odman, P
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1998, 56 (02) : 70 - 75
  • [43] Randomized clinical split-mouth study on a novel self-adhesive bulk-fill restorative vs. a conventional bulk-fill composite for restoration of class II cavities - results after three years
    Cieplik, Fabian
    Hiller, Karl-Anton
    Buchalla, Wolfgang
    Federlin, Marianne
    Scholz, Konstantin J.
    [J]. JOURNAL OF DENTISTRY, 2022, 125
  • [44] A two-year follow-up study in Korean patients with fibromyalgia
    Lee, SS
    Yoon, HJ
    [J]. ARTHRITIS AND RHEUMATISM, 2004, 50 (09): : S310 - S311
  • [45] Durability of endourologic skills: Two-year follow-up study
    Chatterjee, Suman
    Radomski, Sidney B.
    Matsumoto, Edward D.
    [J]. JOURNAL OF ENDOUROLOGY, 2007, 21 (08) : 843 - 846
  • [46] Cariogram Validity in Schoolchildren: A Two-Year Follow-Up Study
    Campus, G.
    Cagetti, M. G.
    Sale, S.
    Carta, G.
    Lingstrom, P.
    [J]. CARIES RESEARCH, 2012, 46 (01) : 16 - 22
  • [47] A Randomized 10-year Prospective Follow-up of Class II Nanohybrid and Conventional Hybrid Resin Composite Restorations
    van Dijken, Jan W. V.
    Pallesen, Ulla
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2014, 16 (06): : 585 - 592
  • [48] In vitro evaluation of microleakage in Class II composite restorations: High-viscosity bulk-fill vs conventional composites
    Garcia Mari, Laura
    Climent Gil, Arantxa
    Llena Puy, Carmen
    [J]. DENTAL MATERIALS JOURNAL, 2019, 38 (05) : 721 - 727
  • [49] Correction to: Internal and marginal adaptation of high-viscosity bulk-fill composites in class II cavities placed with different adhesive strategies
    Rainer Haak
    Thomas Näke
    Kyung-Jin Park
    Dirk Ziebolz
    Felix Krause
    Hartmut Schneider
    [J]. Odontology, 2019, 107 : 418 - 419
  • [50] Mobility of lumbar segments instrumented with a ProDisc II prosthesis - A two-year follow-up study
    Leivseth, Gunnar
    Braaten, Sjur
    Frobin, Wolfgang
    Brinckmann, Paul
    [J]. SPINE, 2006, 31 (15) : 1726 - 1733