A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply

被引:40
|
作者
Srinivasan, A
Bova, G
Ross, T
Mackie, K
Paquette, N
Merz, W
Perl, TM
机构
[1] Johns Hopkins Med Inst, Dept Med, Div Infect Dis, Baltimore, MD 21205 USA
[2] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD 21205 USA
[3] Johns Hopkins Med Inst, Hosp Epidemiol & Infect Control, Baltimore, MD 21205 USA
来源
关键词
D O I
10.1086/502254
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To assess the safety and efficacy of a chlorine dioxide water treatment system in controlling Legionella in a hospital water supply. DESIGN: For 17 months following installation of the system, we performed regular water cultures throughout the building, assessed chlorine dioxide and chlorite levels, and monitored metal corrosion. RESULTS: Sites that grew Legionella species decreased from 41% at baseline to 4% (P = .001). L. anisa was the only species recovered and it was found in samples of both hot and cold water. Levels of chlorine dioxide and chlorite were below Environmental Protection Agency (EPA) limits for these chemicals in potable water. Further, enhanced carbon filtration effectively removed the chemicals, even at chlorine dioxide levels of more than twice what was used to treat the water. After 9 months, corrosion of copper test strips exposed to the chlorine dioxide was not higher than that of control strips. During the evaluation period, there were no cases of nosocomial Legionella in the building with the system, whereas there was one case in another building. CONCLUSIONS: Our results indicate that operation of a chlorine dioxide system effectively removed Legionella species from a hospital water supply. Furthermore, we found that the system was safe, as levels of chlorine dioxide and chlorite were below EPA limits. The system did not appear to cause increased corrosion of copper pipes. Our results indicate that chlorine dioxide may hold promise as a solution to the problem of Legionella contamination of hospital water supplies.
引用
收藏
页码:575 / 579
页数:5
相关论文
共 50 条
  • [1] Comparison of chlorine and chlorine dioxide disinfection for control of Legionella in a hospital potable water supply
    Hamilton, E
    Seal, DV
    Hay, J
    [J]. JOURNAL OF HOSPITAL INFECTION, 1996, 32 (02) : 156 - 160
  • [2] Safety and efficacy of chlorine dioxide for Legionella control in a hospital water system
    Zhang, Zhe
    McCann, Carole
    Stout, Janet E.
    Piesczynski, Steve
    Hawks, Robert
    Vidic, Radisav
    Yu, Victor L.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2007, 28 (08): : 1009 - 1012
  • [3] Legionella control by chlorine dioxide in hospital water systems
    Zhang, Zhe
    Mccann, Carole
    Hanrahan, Jennifer
    Jencson, Annette
    Joyce, Daniel
    Fyffe, Steven
    Piesczynski, Steve
    Hawks, Robert
    Stout, Janet E.
    Yu, Victor L.
    Vidic, Radisav D.
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2009, 101 (05): : 117 - +
  • [4] CONTROL OF LEGIONELLA-PNEUMOPHILA IN A HOSPITAL WATER-SYSTEM BY CHLORINE DIOXIDE
    WALKER, JT
    MACKERNESS, CW
    MALLON, D
    MAKIN, T
    WILLIETS, T
    KEEVIL, CW
    [J]. JOURNAL OF INDUSTRIAL MICROBIOLOGY, 1995, 15 (04): : 384 - 390
  • [5] Control of Legionella in a hospital potable water supply
    Williams, P
    [J]. JOURNAL OF HOSPITAL INFECTION, 1997, 37 (02) : 167 - 169
  • [6] Control of Legionella in a hospital potable water supply - Reply
    Hamilton, E
    Hay, J
    Seal, D
    [J]. JOURNAL OF HOSPITAL INFECTION, 1997, 37 (02) : 169 - 171
  • [7] Chlorine dioxide as a treatment for ballast water to control invasive species: Shipboard testing
    Maranda, Lucie
    Cox, Annie M.
    Campbell, Robert G.
    Smith, David C.
    [J]. MARINE POLLUTION BULLETIN, 2013, 75 (1-2) : 76 - 89
  • [8] Effects of disinfection by chlorine and chlorine dioxide on pipeline biofilm in hot water supply system
    Chai, Shanshan
    Li, Xing
    Yang, Yanling
    Liu, Yongwang
    Zhao, Li
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2019, 51 (02): : 51 - 57
  • [9] Molecular epidemiology of Legionella pneumophila serogroup 1 isolates following long-term chlorine dioxide treatment in a university hospital water system
    Casini, B.
    Valentini, P.
    Baggiani, A.
    Torracca, F.
    Frateschi, S.
    Nelli, L. Ceccherini
    Privitera, G.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2008, 69 (02) : 141 - 147
  • [10] Numerical calculation of chlorine dioxide concentration in drinking water supply system
    Goricanec, D
    Krope, J
    [J]. WATER RESOURCES MANAGEMENT II, 2003, 8 : 55 - 64