The influence of electrode location errors on EEG dipole source localization with a realistic head model

被引:56
|
作者
Wang, YH [1 ]
Gotman, J [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
关键词
electroencephalogram; dipole source localization; electrode position; realistic head model; noise effect;
D O I
10.1016/S1388-2457(01)00594-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Inaccurate information about the electrode locations on the scalp will introduce errors in electroencephalogram dipole source localization results. The present study uses computer simulations to evaluate such errors in a realistic head model and in the context of noise. Methods: A realistic head model was constructed from magnetic resonance imaging scans and 29 electrodes placed on the head according to the 10-20 International System. Twenty sets of electrode displacements, with a mean, value of 5 mm, were generated and 200 single dipoles evenly located in the brain were used as test sources. The boundary element method was employed for the froward calculation and dipole fitting was carried out at different noise levels. Results: For a noise-free signal, the source localization error due to electrode misplacement is about 5 mm, whereas it is about 2 mm for normal noisy signals. Conclusions: For realistic head models, dipole estimation error due to electrode misplacement is negligible compared with errors caused by noise. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:1777 / 1780
页数:4
相关论文
共 50 条
  • [1] A standard realistic head model for EEG dipole localization
    Silva, C
    Almeida, R
    Foreid, JP
    Oostendorp, T
    Ducla-Soares, E
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1594 - 1595
  • [2] A simulation study of the error in dipole source localization for EEG spikes with a realistic head model
    Kobayashi, K
    Yoshinaga, H
    Oka, M
    Ohtsuka, Y
    Gotman, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2003, 114 (06) : 1069 - 1078
  • [3] Bayesian EEG dipole source localization using SA-RJMCMC on realistic head model
    Yildiz, Gokcen
    Duru, A. Deniz
    Ademoglu, Ahmet
    Demiralp, Tamer
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4268 - +
  • [4] MEG/EEG error bounds for a dipole source with a realistic head model
    Muravchik, CH
    Nehorai, A
    [J]. THIRTIETH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, VOLS 1 AND 2, 1997, : 1386 - 1390
  • [5] Dipole estimation errors in EEG source localization due to not incorporating anisotropic conductivities of white matter in realistic head models
    Hallez, Hans
    Vanrumste, Bart
    Deputte, Steven
    Van Hese, Peter
    Assecondi, Sara
    D'Asseler, Yves
    Lemahieu, Ignace
    [J]. 2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 51 - +
  • [6] MEG/EEG numerical error bounds for a dipole source with a realistic head model
    Muravchik, CH
    Nehorai, A
    [J]. PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1233 - 1236
  • [7] Error bounds of EEG/MEG for a stationary dipole source with a realistic head model
    Muravchik, CH
    Nehorai, A
    [J]. 2000 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS, VOLS I-VI, 2000, : 3763 - 3766
  • [8] EEG/MEG error bounds for a static dipole source with a realistic head model
    Muravchik, CH
    Nehorai, A
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2001, 49 (03) : 470 - 484
  • [9] EEG/MEG error bounds for a dynamic dipole source with a realistic head model
    Muravchik, C
    Bria, O
    Nehorai, A
    [J]. METHODS OF INFORMATION IN MEDICINE, 2000, 39 (02) : 110 - 113
  • [10] Dipole estimation errors due to not incorporating anisotropic conductivities in realistic head models for EEG source analysis
    Hallez, Hans
    Staelens, Steven
    Lemahieu, Ignace
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6079 - 6093