Synergy of active and passive airborne thermal infrared systems for surface compositional mapping

被引:8
|
作者
Hook, SJ
Cudahy, TJ
Kahle, AB
Whitbourn, LB
机构
[1] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
[2] CSIRO, Explorat & Min, N Ryde, NSW 2113, Australia
关键词
D O I
10.1029/98JB01273
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
NASA thermal infrared multispectral scanner (TIMS) and Commonwealth Scientific Industrial Research Organisation mid-infrared airborne CO2 laser spectrometer (MIRACO(2)LAS) data were acquired over the Mount Fitton area, South Australia, in order to evaluate their combined use for geological mapping and mineral exploration. TIMS is a passive, imaging system with six spectral bands in the thermal infrared wavelength region (8-12 mu m), whereas MIRACO(2)LAS is an active, profiling system with similar to 100 spectral bands in the 9-11 mu m spectral range. The TIMS and CO2 laser data (emissivity variations for TIMS and apparent reflectance for MIRACO(2)LAS) were processed to enhance spectral information related to the surface composition. This spectral information was compared with existing geological maps and field emissivity spectra. Known geological units were well discriminated in the TIMS imagery, including a range of quartz-rich and carbonate-rich sedimentary units, as well as several previously unmapped areas of alteration in the carbonate rocks. However, the broadband spectral resolution of TIMS did not allow identification of discrete mineral constituents. In contrast, the high spectral resolution MIRACO(2)LAS data provided diagnostic spectral information about a range of minerals present including quartz, dolomite, talc, and tremolite, albeit, along discrete profiles. The widths of some of these diagnostic spectral features were less than 0.2 mu m wide, which is half the resolution of the TIMS band passes (0.4 mu m). The MIRACO(2)LAS spectra closely matched the shape, location, and depth of spectra of field samples measured by both a field emission spectrometer and a laboratory laser spectrometer. Pure mineral spectra measured by the (bidirectional) laboratory laser spectrometer also closely matched those measured by a conventional laboratory spectrometer measuring directional hemispherical reflectance. These results indicate that future remote thermal infrared systems designed for improved geological mapping and mineral exploration should incorporate both an imager for mapping lithological units and a high spectral resolution profiler for identifying dominant mineral constituents. Recently, a hyperspectral imaging thermal infrared instrument has been developed termed Spatially Enhanced Broadband Array Spectrograph System (SEBASS) [Hackwell and Warren, 1997]. This instrument should allow spectral identification of an entire scene [Gillespie et al., 1997], although the swath width is currently limited to 128 pixels as opposed to the 752 pixels of TIMS after panoramic correction.
引用
收藏
页码:18269 / 18276
页数:8
相关论文
共 50 条
  • [21] Calibration Method for Airborne Infrared Optical Systems in a Non-Thermal Equilibrium State
    Dong, Mingyuan
    Shen, Honghai
    Jia, Ping
    Sun, Yang
    Liang, Chao
    Zhang, Fan
    Hou, Jinghua
    SENSORS, 2023, 23 (14)
  • [22] Optimization of the combined processing of fields of radiothermal scattered and self-radiation in the combined active-passive systems of surface mapping
    Volosyuk, VK
    Kravchenko, VF
    Pustovoit, VI
    DOKLADY AKADEMII NAUK, 1999, 366 (01) : 43 - 46
  • [23] On observing the compositional variability of the surface of Venus using nightside near-infrared thermal radiation
    Hashimoto, GL
    Sugita, S
    JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2003, 108 (E9)
  • [24] Active Control and Spatial Mapping of Mid-Infrared Propagating Surface Plasmons
    Ribaudo, T.
    Shaner, E. A.
    Howard, S. S.
    Gmachl, C.
    Wang, X. J.
    Choa, F. -S.
    Wasserman, D.
    OPTICS EXPRESS, 2009, 17 (09): : 7019 - 7024
  • [25] Active Control and Spatial Mapping of Mid-Infrared Propagating Surface Plasmons
    Ribaudo, T.
    Shaner, E. A.
    Howard, S. S.
    Gmachl, C.
    Wang, X.
    Choa, F. S.
    Wasserman, D.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 1862 - +
  • [26] Evaluation of Active and Passive UAV-Based Surveying Systems for Eulittoral Zone Mapping
    Arav, Reuma
    Ressl, Camillo
    Weiss, Robert
    Artz, Thomas
    Mandlburger, Gottfried
    MID-TERM SYMPOSIUM THE ROLE OF PHOTOGRAMMETRY FOR A SUSTAINABLE WORLD, VOL. 48-2, 2024, : 9 - 16
  • [27] Remote imaging of controlled gas releases using active and passive infrared imaging systems
    Kulp, TJ
    Powers, PE
    Kennedy, R
    INFRARED TECHNOLOGY AND APPLICATIONS XXIII, PTS 1 AND 2, 1997, 3061 : 269 - 278
  • [28] Thermal performances of the active and passive water heating systems based on annual operation
    Lee, Dong Won
    Sharma, Atul
    SOLAR ENERGY, 2007, 81 (02) : 207 - 215
  • [29] SEBASS hyperspectral thermal infrared data: surface emissivity measurement and mineral mapping
    Vaughan, RG
    Calvin, WM
    Taranik, JV
    REMOTE SENSING OF ENVIRONMENT, 2003, 85 (01) : 48 - 63
  • [30] INFRARED THERMAL MAPPING OF MARTIAN SURFACE AND ATMOSPHERE - 1ST RESULTS
    KIEFFER, HH
    CHASE, SC
    MINER, ED
    PALLUCONI, FD
    MUNCH, G
    NEUGEBAUER, G
    MARTIN, TZ
    SCIENCE, 1976, 193 (4255) : 780 - 786