Performance and applications of a spectrometer with micromachined scanning grating

被引:4
|
作者
Grüger, H [1 ]
Schuster, T [1 ]
Wolter, A [1 ]
Schenk, H [1 ]
Lakner, H [1 ]
机构
[1] Fraunhofer Inst Microelect Circuits & Syst, D-01109 Dresden, Germany
关键词
spectrometer; spectroscopy; applications; performance; resonant; scanning grating; micro scanning mirror; MEMS; MOEMS;
D O I
10.1117/12.478317
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Micro Opto Electro Mechanical Systems (MOEMS) gain more. and more importance in technical applications.. The combination of optical actuators and micromachined silicon technology arise possibilities to realize equipment in high volumes for reasonable prices, that have formerly been expensive laboratory equipment. This paper reports on the performance and applications of a spectrometer in MOEMS technology. It is based on a scanning mirror chip with a grating structure on top. Thus a spectrometer with selectable wavelength range was realized. The resolution is not limited by line width of a multisensor detector, as it is the case for state of the art low cost spectrometers. A single detector is used, cheaper than arrays and available for all wavelength ranges. The setup can be small and light, the grating withstands shocks and vibration much better than a classical spectrometer. The grating moves with a frequency of 500 Hz respectively 1000 Hz, a whole spectrum is acquired within milliseconds. The resolution is given by the grating line density and the spectrometer dimensions, as it is valid for every single detector spectrometer. Depending on the number of systems built, a price of the system can be expected significantly below those of low cost systems with fixed grating. Many possibilities arise in every application where light is analyzed spectroscopically.
引用
收藏
页码:284 / 291
页数:8
相关论文
共 50 条
  • [31] Single-detector micro-electro-mechanical scanning grating spectrometer
    M. Kraft
    A. Kenda
    A. Frank
    W. Scherf
    A. Heberer
    T. Sandner
    H. Schenk
    F. Zimmer
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1259 - 1266
  • [32] Design and early performance of IGRINS (Immersion Grating Infrared Spectrometer)
    Park, Chan
    Jaffe, Daniel T.
    Yuk, In-Soo
    Chun, Moo-Young
    Pak, Soojong
    Kim, Kang-Min
    Pavel, Michael
    Lee, Hanshin
    Oh, Heeyoung
    Jeong, Ueejeong
    Sim, Chae Kyung
    Lee, Hye-In
    Huynh Anh Nguyen Le
    Strubhar, Joseph
    Gully-Santiago, Michael
    Oh, Jae Sok
    Cha, Sang-Mok
    Moon, Bongkon
    Park, Kwijong
    Brooks, Cynthia
    Ko, Kyeongyeon
    Han, Jeong-Yeol
    Nah, Jakyoung
    Hill, Peter C.
    Lee, Sungho
    Barnes, Stuart
    Yu, Young Sam
    Kaplan, Kyle
    Mace, Gregory
    Kim, Hwihyun
    Lee, Jae-Joon
    Hwang, Narae
    Park, Byeong-Gon
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY V, 2014, 9147
  • [33] Influence of wavefront aberration on the imaging performance of the solar grating spectrometer
    Zheng, L. H.
    Rao, C. H.
    Gu, N. T.
    Huang, L. H.
    Qiu, Q.
    OPTICS EXPRESS, 2016, 24 (01): : 153 - 167
  • [34] Inflight Performance of the TanSat Atmospheric Carbon Dioxide Grating Spectrometer
    Yang, Zhongdong
    Bi, Yan-Meng
    Wang, Qian
    Liu, Cheng-Bao
    Gu, Song-Yan
    Zheng, Yuquan
    Lin, Chao
    Yin, Zengshan
    Tian, Longfei
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2020, 58 (07): : 4691 - 4703
  • [35] PERFORMANCE OF A COMMERICAL RAPID SCANNING SPECTROMETER IN EMISSION AND ABSORPTION
    BABROV, HJ
    TOURIN, RH
    APPLIED OPTICS, 1968, 7 (11): : 2171 - &
  • [37] Silicon Micromachined Terahertz Spectrometer Instruments
    Chattopadhyay, Goutam
    Reck, Theodore
    Jung-Kubiak, Cecile
    Gonzalez-Ovejero, David
    Tang, Adrian
    Lee, Choonsup
    Alonso-DelPino, Maria
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [38] Influence of spectrometer scanning requirements in homemade grating diffuse NIR instrument on NIR veracity
    Qin, Xi-Yun
    Li, Jun-Hui
    Yang, Yu-Hong
    Cai, Gui-Min
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2007, 27 (02): : 411 - 413
  • [39] Design and Simulation of Single Detector NIR Spectrometer Based on Torsional MOEMS Scanning Grating
    Huang, J.
    Wen, Z. Y.
    Chang, F.
    MICRO-NANO TECHNOLOGY XVII-XVIII, 2018, : 218 - 223
  • [40] Integrated scanning spectrometer with a tunable micro-ring resonator and an arrayed waveguide grating
    ZUNYUE ZHANG
    YI WANG
    JIARUI WANG
    DAN YI
    DAVID WENG U CHAN
    WU YUAN
    HON KI TSANG
    Photonics Research, 2022, 10 (05) : 74 - 81