Numerical analysis of the influence of magnetic field waveforms on the performance of active magnetic regenerators

被引:8
|
作者
Fortkamp, Fabio P. [1 ]
Lang, Gusttav B. [1 ]
Lozano, Jaime A. [1 ]
Barbosa Jr, Jader R. [1 ]
机构
[1] Univ Fed Santa Catarina, POLO Res Labs Emerging Technol Cooling & Thermoph, Dept Mech Engn, BR-88040900 Florianopolis, SC, Brazil
关键词
Magnetic refrigeration; Active magnetic regenerator; Numerical modeling; Magnetocaloric effect; MULTIOBJECTIVE OPTIMIZATION; THERMODYNAMIC CYCLES; DESIGN; TEMPERATURE;
D O I
10.1007/s40430-020-02453-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Magnetic cooling is an alternative to vapor compression that does not rely on the use of hazardous substances. The refrigerant is a solid material which reacts to oscillations in magnetic field by changing its temperature (the magnetocaloric effect). In active magnetic regenerators, the magnetocaloric material arranged as a porous medium is subjected to an oscillating fluid flow to allow heat transfer from a cold source to a hot sink in a thermodynamic cooling cycle. Although the literature is abundant with studies on the influence of the fluid flow waveform on magnetic refrigeration devices, the influence of the magnetic field waveform has been much less investigated. In this work, we make use of an active magnetic regenerator numerical model with different mathematically defined waveforms to determine which operating parameters yield the highest values of cooling capacity and coefficient of performance for a specific set of operating conditions. The results show that the best performance is achieved when the magnetic field is kept constant for the same time duration of the fluid flow through the magnetized material, and the transition times between the high and low levels of the magnetic field should be as short as possible.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] A dimensionless description of active magnetic regenerators to compare their performance and to simplify their optimization
    Tagliafico, Giulio
    Scarpa, Federico
    Tagliafico, Luca A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 941 - 949
  • [22] Experimental study on cooling performance of active magnetic regenerators with different structures
    Yuan, Lifen
    Liu, Ye
    Yu, Jianlin
    Qian, Suxin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 184 - 193
  • [23] An efficient numerical scheme for the simulation of parallel-plate active magnetic regenerators
    Torregrosa-Jaime, Barbara
    Corberan, Jose M.
    Paya, Jorge
    Engelbrecht, Kurt
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 : 121 - 130
  • [24] Thermodynamic investigations of optimum active magnetic regenerators
    Smaili, A
    Chahine, R
    CRYOGENICS, 1998, 38 (02) : 247 - 252
  • [25] Thermodynamics of active magnetic regenerators: Part II
    Rowe, Andrew
    CRYOGENICS, 2012, 52 (2-3) : 119 - 128
  • [26] Ideal magnetocaloric effect for active magnetic regenerators
    Rowe, AM
    Barclay, JA
    JOURNAL OF APPLIED PHYSICS, 2003, 93 (03) : 1672 - 1676
  • [27] Integrated design of active magnetic regenerators and heat exchangers for magnetic refrigerators
    Peixer, Guilherme F.
    Calomeno, Ricardo S.
    Lang, Gusttav B.
    Lozano, Jaime A.
    Barbosa, Jader R., Jr.
    THERMAG VIII - INTERNATIONAL CONFERENCE ON CALORIC COOLING, 2018, : 226 - 231
  • [28] LOCATION DEPENDENT PERFORMANCE STUDY ON REGENERATORS WITHIN A HALBACH MAGNETIC FIELD SOURCE
    Christiaanse, T. V.
    Govindappa, P.
    Niknia, I.
    Teyber, R.
    Trevizoli, P. V.
    Rowe, A.
    7TH INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2016, : 75 - 78
  • [29] Numerical analysis of an active magnetic regenerator
    Roudaut, J.
    Kedous-Lebouc, A.
    Yonnet, J. -P.
    Muller, C.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2011, 34 (08) : 1797 - 1804
  • [30] Static and rotating active magnetic regenerators with porous heat exchangers for magnetic cooling
    Sarlah, A.
    Kitanovski, A.
    Poredos, A.
    Egolf, P. W.
    Sari, O.
    Gendre, F.
    Besson, Ch.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1332 - 1339