Efficiency of High-Resolution MRI at Different Stages of Subchondral Insufficiency Fracture of the Knee

被引:0
|
作者
Ivankov, Akeksandr [1 ]
Seliverstov, Pavel [1 ]
机构
[1] Irkutsk Sci Ctr Surg & Traumatol, Irkutsk, Russia
关键词
high-resolution MRI; osteoporosis; knee;
D O I
10.21103/Article12(1)-ShC2
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The history of subchondral insufficiency fracture is closely related to a pre-existing diagnosis of spontaneous osteonecrosis of the knee (SONK). Previously, it was thought that subchondral linear or lunate pathological changes on magnetic resonance imaging (MRI) scans in elderly patients with a history of osteoporosis are the result of spontaneous osteonecrosis, but in the 2000s, studies by T. Yamamoto showed that a small proportion of patients with osteonecrosis of the femoral head initially have a fracture of insufficiency that gets complicated by secondary osteonecrosis. Subsequent studies of SONK also showed that the subchondral insufficiency fracture is precisely the initial process, osteonecrosis is secondary and it is a complication of the fracture. The aim of our study was to evaluate the effectiveness of high-resolution MRI at different stages of this disease.
引用
收藏
页码:67 / 69
页数:3
相关论文
共 50 条
  • [21] High-resolution MRI detects cartilage swelling at the early stages of experimental osteoarthritis
    Calvo, E
    Palacios, I
    Delgado, E
    Ruiz-Cabello, J
    Hernández, P
    Sánchez-Pernaute, O
    Egido, J
    Herrero-Beaumont, G
    OSTEOARTHRITIS AND CARTILAGE, 2001, 9 (05) : 463 - 472
  • [22] A high-resolution phantom for MRI
    Fellner, C
    Müller, W
    Georgi, J
    Taubenreuther, U
    Fellner, FA
    Kalender, WA
    MAGNETIC RESONANCE IMAGING, 2001, 19 (06) : 899 - 904
  • [23] High-resolution diffusion MRI
    Haldar, Justin P.
    Liang, Zhi-Pei
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 311 - 314
  • [24] High-Resolution MRI and Metabolism
    Weil, Erika Layne
    Finn, Quentin
    Eid, Abdulmunaim M.
    Karmonik, Christof
    Pascual, Belen
    Masdeu, Joseph C.
    Alzheimer Dis Neuroimaging Initiative
    NEUROLOGY, 2025, 104 (04)
  • [25] A high-resolution phantom for MRI
    Fellner, C
    Mueller, W
    Georgi, J
    Taubenreuther, U
    Fellner, FA
    Kalender, WA
    RADIOLOGY, 2001, 221 : 163 - 164
  • [26] Advantages of cone beam computed tomography for evaluation of subchondral insufficiency fractures of the knee compared to MRI
    Delsmann, Maximilian M.
    Delsmann, Julian
    Jandl, Nico Maximilian
    Maas, Kai-Jonathan
    Beil, Frank Timo
    Amling, Michael
    Henes, Frank Oliver
    Rolvien, Tim
    Spink, Clemens
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [27] High-resolution PET & high-resolution MRI assessment of hand osteoarthritis
    Tan, A.
    Waller, M.
    Grainger, A.
    Tanner, S.
    Emery, P.
    Benjamin, M.
    McGonagle, D.
    ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 : 21 - 22
  • [28] HIGH-RESOLUTION SONOGRAPHY OF THE MENISCI OF THE KNEE
    SELBY, B
    RICHARDSON, ML
    MONTANA, MA
    TEITZ, CC
    LARSON, RV
    MACK, LA
    INVESTIGATIVE RADIOLOGY, 1986, 21 (04) : 332 - 335
  • [29] HIGH-RESOLUTION SONOGRAPHY OF THE MENISCI OF THE KNEE
    SELBY, B
    RICHARDSON, ML
    MONTANA, MA
    MACK, LA
    INVESTIGATIVE RADIOLOGY, 1985, 20 (06) : S5 - S5
  • [30] Rapid progression of joint deformity after subchondral insufficiency fracture of the knee with medial meniscal root tear
    Mori, Yu
    Mori, Naoko
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (07) : 749 - 750