Contrast-Enhanced Computed Tomography Enables Quantitative Evaluation of Tissue Properties at Intrajoint Regions in Cadaveric Knee Cartilage

被引:19
|
作者
Stewart, Rachel C. [1 ,2 ]
Honkanen, Juuso T. J. [3 ,4 ]
Kokkonen, Harri T. [4 ]
Tiitu, Virpi [5 ]
Saarakkala, Simo [6 ,7 ,8 ,9 ]
Joukainen, Antti [10 ]
Snyder, Brian D. [2 ]
Jurvelin, Jukka S. [3 ,4 ]
Grinstaff, Mark W. [1 ,11 ]
Toyras, Juha [3 ,4 ]
机构
[1] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Ctr Adv Orthopaed Studies, Boston, MA 02215 USA
[3] Univ Eastern Finland, Dept Appl Phys, POB 1627, Kuopio 70211, Finland
[4] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[5] Univ Eastern Finland, Inst Biomed, Anat, Kuopio, Finland
[6] Univ Oulu, Fac Med, Res Unit Med Imaging Phys & Technol, Oulu, Finland
[7] Oulu Univ Hosp, Dept Diagnost Radiol, Oulu, Finland
[8] Oulu Univ Hosp, Med Res Ctr Oulu, Oulu, Finland
[9] Univ Oulu, Oulu, Finland
[10] Kuopio Univ Hosp, Dept Orthopaed Traumatol & Hand Surg, Kuopio, Finland
[11] Boston Univ, Dept Chem, Boston, MA 02215 USA
基金
欧洲研究理事会; 芬兰科学院; 美国国家卫生研究院;
关键词
cartilage imaging; contrast enhanced computed tomography; osteoarthritis; cone beam computed tomography; ARTICULAR-CARTILAGE; IN-VIVO; CT-ARTHROGRAPHY; GLYCOSAMINOGLYCAN CONTENT; OSTEOARTHRITIS; AGENT; INDENTATION; MORPHOLOGY; DENSITY; QUALITY;
D O I
10.1177/1947603516665443
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. The aim of this study was to investigate whether the concentration of the anionic contrast agent ioxaglate, as quantitated by contrast-enhanced computed tomography (CECT) using a clinical cone-beam CT (CBCT) instrument, reflects biochemical, histological, and biomechanical characteristics of articular cartilage imaged in an ex vivo, intact human knee joint. Design. An osteoarthritic human cadaveric knee joint (91 years old) was injected with ioxaglate (36 mg l/mL) and imaged using CBCT over 61 hours of ioxaglate diffusion into cartilage. Following imaging, the joint surfaces were excised, rinsed to remove contrast agent, and compressive stiffness (equilibrium and instantaneous compressive moduli) was measured via indentation testing (n = 17 sites). Each site was sectioned for histology and assessed for glycosaminoglycan content using digital densitometry of Safranin-O stained sections, Fourier transform infrared spectroscopy for collagen content, and morphology using both the Mankin and OARSI semiquantitative scoring systems. Water content was determined using mass change after lyophilization. Results. CECT attenuation at all imaging time points, including those <1 hour of ioxaglate exposure, correlated significantly (P < 0.05) with cartilage water and glycosaminoglycan contents, Mankin score, and both equilibrium and instantaneous compressive moduli. Early time points (< 30 minutes) also correlated (P < 0.05) with collagen content and OARSI score. Differences in cartilage quality between intrajoint regions were distinguishable at diffusion equilibrium and after brief ioxaglate exposure. Conclusions. CECT with ioxaglate affords biochemical and biomechanical measurements of cartilage health and performance even after short, clinically relevant exposure times, and may be useful in the clinic as a means for detecting early signs of cartilage pathology.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 50 条
  • [21] Multifactorial Optimization of Contrast-Enhanced Nanofocus Computed Tomography for Quantitative Analysis of Neo-Tissue Formation in Tissue Engineering Constructs
    Sonnaert, Maarten
    Kerckhofs, Greet
    Papantoniou, Ioannis
    Van Vlierberghe, Sandra
    Boterberg, Veerle
    Dubruel, Peter
    Luyten, Frank P.
    Schrooten, Jan
    Geris, Liesbet
    PLOS ONE, 2015, 10 (06):
  • [22] Evaluation of equine articular cartilage degeneration after mechanical impact injury using cationic contrast-enhanced computed tomography
    Nelson, B. B.
    Makela, J. T. A.
    Lawson, T. B.
    Patwa, A. N.
    Barrett, M. F.
    McIlwraith, C. W.
    Hurtig, M. B.
    Snyder, B. D.
    Moorman, V. J.
    Grinstaff, M. W.
    Goodrich, L. R.
    Kawcak, C. E.
    OSTEOARTHRITIS AND CARTILAGE, 2019, 27 (08) : 1219 - 1228
  • [23] Comparison of quantitative imaging of cartilage for osteoarthritis: T2, T1ρ, dGEMRIC and contrast-enhanced computed tomography
    Taylor, Carmen
    Carballido-Gamio, Julio
    Majumdar, Sharmila
    Li, Xiaojuan
    MAGNETIC RESONANCE IMAGING, 2009, 27 (06) : 779 - 784
  • [24] Tantalum Oxide Nanoparticles for the Quantitative Contrast-Enhanced Computed Tomography of Ex Vivo Human Cartilage: Assessment of Biochemical Composition and Biomechanics
    Lawson, Taylor
    Joenathan, Anisha
    Patwa, Amit
    Snyder, Brian D.
    Grinstaff, Mark W.
    ACS NANO, 2021, 15 (12) : 19175 - 19184
  • [25] EXPLORING GLYCOSAMINOGLYCAN DISTRIBUTION IN CARTILAGE TISSUES USING CONTRAST-ENHANCED MICRO-COMPUTED TOMOGRAPHY
    Boos, Manuela A.
    Rathnayake, Manula S. B.
    Stok, Kathryn S.
    TISSUE ENGINEERING PART A, 2022, 28 : S375 - S375
  • [26] Determining collagen distribution in articular cartilage using contrast-enhanced micro-computed tomography
    Nieminen, H. J.
    Ylitalo, T.
    Karhula, S.
    Suuronen, J. -P.
    Kauppinen, S.
    Serimaa, R.
    Haeggstrom, E.
    Pritzker, K. P. H.
    Valkealahti, M.
    Lehenkari, P.
    Finnila, M.
    Saarakkala, S.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (09) : 1613 - 1621
  • [27] QUANTITATIVE IN VIVO EVALUATION OF NEOINTIMAL HYPERPLASIA USING HIGHRESOLUTION CONTRAST-ENHANCED CONE-BEAM COMPUTED TOMOGRAPHY
    van der Bom, Imramsjah M. J.
    Strittmatter, Lara
    Hendricks, Gregory H.
    Kuehn, Anna Luisa
    Wakhloo, Ajay K.
    Gounis, Matthew J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [28] SURFACE CHARACTERIZATION OF DEGENERATED ARTICULAR CARTILAGE SURFACE BY CONTRAST-ENHANCED MICRO-COMPUTED TOMOGRAPHY
    Ylitalo, T. J.
    Finnila, M.
    Karhula, S.
    Haeggstrom, E.
    Pritzker, K. P.
    Saarakkala, S.
    Nieminen, H. J.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 : A249 - A250
  • [29] Evaluation of canine lumbosacral stenosis using intravenous contrast-enhanced computed tomography
    Jones, JC
    Shires, PK
    Inzana, KD
    Sponenberg, DP
    Massicotte, C
    Renberg, W
    Giroux, A
    VETERINARY RADIOLOGY & ULTRASOUND, 1999, 40 (02) : 108 - 114
  • [30] EVALUATION OF ACUTE MYOCARDIAL-INFARCTION BY CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY
    GOLDSTEIN, JA
    LIPTON, MJ
    KRAMER, PH
    BRUNDAGE, BH
    CLINICAL RESEARCH, 1982, 30 (01): : A10 - A10