Three-dimensional simulation on the thermal performance of a novel Trombe wall with venetian blind structure

被引:87
|
作者
Hong, Xiaoqiang [1 ]
He, Wei [1 ]
Hu, Zhongting [1 ]
Wang, Chenchen [1 ]
Ji, Jie [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China
关键词
Trombe wall; Three-dimensional simulation; CFD; Heat transfer;
D O I
10.1016/j.enbuild.2014.12.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A complete three-dimensional CFD model was developed to investigate the flow and thermal transport in a novel Trombe wall equipped with a venetian blind. The model was involved in flow and heat transfer in the Trombe wall, which was conjugated with heat conduction in the venetian blind. An experimental rig was constructed and utilized to validate the CFD prediction. It was found that the established model is able to predict the operational performance of the system at a reasonable accuracy. Effect of structural parameters of the Trombe wall was investigated in details under the specific operational condition. The present study indicates that the position of the venetian blind, the width of the air duct and the area of the inlet and outlet vents influence the thermal performance of the system. The results predicted that the optimum of the distance between the glass and the venetian blind is 0.09 m for an air duct of 0.14 m width, the width of the air duct is 0.14 m and the area of each vent is 0.60 m width x 0.10 m height. The research results would assist in developing a high efficient solar air heating system and thus help reduce fossil fuel consumption in the building sector. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 50 条
  • [21] Simulation of thermal crosstalk of resistive switching memory in three-dimensional crossbar structure
    Lu, N. D.
    Sun, P. X.
    Li, L.
    Liu, M.
    Sun, P. X.
    Li, Y. T.
    Liu, S.
    2015 INTERNATIONAL CONFERENCE ON SIMULATION OF SEMICONDUCTOR PROCESSES AND DEVICES (SISPAD), 2015, : 438 - 441
  • [22] Three-dimensional simulation with a CFD tool of the airflow phenomena in single floor double-skin facade equipped with a venetian blind
    Safer, N
    Woloszyn, M
    Roux, JJ
    SOLAR ENERGY, 2005, 79 (02) : 193 - 203
  • [23] A novel three-dimensional NAND flash structure for improving the erase performance
    Choi, SeonJun
    Oh, Youngtaek
    Song, Yun-Heub
    IEICE ELECTRONICS EXPRESS, 2019, 16 (03):
  • [24] Numerical analysis on the cooling performance of a ventilated Trombe wall combined with venetian blinds in an office building
    Hu, Zhongting
    He, Wei
    Hong, Xiaoqiang
    Ji, Jie
    Shen, Zhihe
    ENERGY AND BUILDINGS, 2016, 126 : 14 - 27
  • [25] Three-dimensional structure of the bacterial cell wall peptidoglycan
    Meroueh, SO
    Bencze, KZ
    Hesek, D
    Lee, M
    Fisher, JF
    Stemmler, TL
    Mobashery, S
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (12) : 4404 - 4409
  • [26] Flow Structure of a Three-Dimensional Turbulent Wall Jet
    A. M. Gaifullin
    A. S. Shcheglov
    Fluid Dynamics, 2023, 58 : 1266 - 1276
  • [27] Flow Structure of a Three-Dimensional Turbulent Wall Jet
    Gaifullin, A. M.
    Shcheglov, A. S.
    FLUID DYNAMICS, 2023, 58 (07) : 1266 - 1276
  • [28] Numerical study on the thermal and electrical performance of a novel MCHP PV-Trombe wall system
    Wang, Lin
    Zhou, Jinzhi
    Bisengimana, Emmanuel
    Ji, Yasheng
    Zhong, Wei
    Yuan, Yanping
    Lu, Lin
    ENERGY, 2023, 269
  • [29] Experimental study on thermal performance of an integrated PCM Trombe wall
    Duan, Shuangping
    Wang, Lin
    Zhao, Zhiqiang
    Zhang, Chengwang
    RENEWABLE ENERGY, 2021, 163 : 1932 - 1941
  • [30] Experimental investigation on the impact of fin structure factors on the finned-Trombe wall thermal performance
    Wu, Shuang-Ying
    Zheng, Hao
    Xiao, Lan
    Xiang, Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 70