Reliability of Quantitative TUG measures of mobility for use in falls risk assessment

被引:0
|
作者
McGrath, Denise [1 ]
Greene, Barry R.
Doheny, Emer P.
McKeown, David J. [1 ]
De Vito, Giuseppe [2 ]
Caulfield, Brian [1 ]
机构
[1] Univ Coll Dublin, TRIL Ctr, Dublin, Ireland
[2] Univ Coll Dublin, Dublin, Ireland
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent advances in body-worn sensor technology have increased the scope for harnessing quantitative information from the timed-up-and-go test (TUG), well beyond simply the time taken to perform the test. Previous research has shown that the quantitative TUG method can differentiate fallers from non-fallers with greater success than the manually timed TUG or the Berg Balance Test. In order to advance this paradigm of falls risk estimation it is necessary to investigate the robustness of the quantitative TUG variables. This study investigated the inter-session and intra-session reliability of 44 quantitative TUG variables measured from the shanks and lower back of 33 study participants aged between 55-65yrs. For intra-session reliability, 25 variables demonstrated excellent reliability (ICC>0.75), and 12 demonstrated "fair to good reliability" with ICCs between 0.4 and 0.75. Analysis of test-retest reliability resulted in ICC > 0.75 for 18 out of 44 variables, with 20 variables showing fair to good reliability. Turn time parameters demonstrated poor reliability. We conclude that this is a reliable instrument that may be used as part of a long-term falls risk assessment, with further work required to improve certain turn parameters.
引用
收藏
页码:466 / 469
页数:4
相关论文
共 50 条
  • [41] Safety and Risk Assessment in Child Welfare: A Reliability Study Using Multiple Measures
    Vial, Annemiek
    Assink, Mark
    Stams, Geert Jan J. M.
    van der Put, Claudia
    JOURNAL OF CHILD AND FAMILY STUDIES, 2019, 28 (12) : 3533 - 3544
  • [42] Functional Mobility Limitations and Falls in Assisted Living Residents With Dementia : Physical Performance Assessment and Quantitative Gait Analysis
    McGough, Ellen L.
    Logsdon, Rebecca G.
    Kelly, Valerie E.
    Teri, Linda
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2013, 36 (02) : 78 - 86
  • [43] Safety and Risk Assessment in Child Welfare: A Reliability Study Using Multiple Measures
    Annemiek Vial
    Mark Assink
    Geert Jan J. M. Stams
    Claudia van der Put
    Journal of Child and Family Studies, 2019, 28 : 3533 - 3544
  • [44] The use of flexible quantile-based measures in risk assessment
    Belles-Sampera, Jaume
    Guillen, Montserrat
    Santolino, Miguel
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2016, 45 (06) : 1670 - 1681
  • [45] FALLS RISK SCREENING AND ASSESSMENT IN ONCOLOGY
    Felton, Kimberly
    ONCOLOGY NURSING FORUM, 2020, 47 (02)
  • [46] Risk assessment of Nambe Falls Dam
    VonThun, JL
    UNCERTAINTY IN THE GEOLOGIC ENVIRONMENT: FROM THEORY TO PRACTICE, VOLS 1 AND 2: PROCEEDINGS OF UNCERTAINTY '96, 1996, (58): : 604 - 635
  • [47] Risk assessment for falls in the elderly population
    Toba, Kenji
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2008, 8 : S26 - S28
  • [48] A quantitative comparison of risk measures
    Pichler, Alois
    ANNALS OF OPERATIONS RESEARCH, 2017, 254 (1-2) : 251 - 275
  • [49] A quantitative comparison of risk measures
    Alois Pichler
    Annals of Operations Research, 2017, 254 : 251 - 275
  • [50] Reliability and validity of pediatric powered mobility outcome measures
    Gefen, Naomi
    Rigbi, Amihai
    Weiss, Patrice L.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2022, 17 (08) : 882 - 887