Transcatheter occlusion of the patent ductus arteriosus with a single device technique: comparison between the Cook detachable coil and the Rashkind umbrella device

被引:6
|
作者
Jaeggi, ET
Fasnacht, M
Arbenz, U
Beghetti, M
Bauersfeld, U
Friedli, B
机构
[1] Univ Geneva, Childrens Hosp, CH-1211 Geneva, Switzerland
[2] Univ Zurich, Childrens Hosp, CH-8032 Zurich, Switzerland
关键词
patent ductus arteriosus; transcatheter occlusion; Rashkind device; coil;
D O I
10.1016/S0167-5273(01)00406-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter coil occlusion of the patent ductus arteriosus (PDA) has become the interventional treatment option of choice. Immediate occlusion of any residual shunting results in excellent closure rates, but frequently requires multiple coil deployment. Aims: To assess the efficacy and limitations of single Cook detachable coil PDA closure compared to a preceding series of Rashkind umbrella procedures. Methods and results: Between 1990 and 1999. transcatheter occlusion of a small (<2 mm: n=45) or moderate-sized (2-4 mm: n=47) PDA was successfully attempted in 90/92 consecutive patients (mean ape 6 +/-4.8 years) with a coil (39/41) or Rashkind device (51/51). Immediate angiographic closure rates for both devices were low. although better for small (54-68%) than moderate ducts (7-22%. P <0.01). A 2-year echocardiographic closure rate of small ducts increased to 92% fur the coil group versus 95% for the Rashkind group. By that rims, moderate-sized ducts were only occluded in 64% with the coil and 54% with the Rashkind device. A visible residual shunt at post-implant angiography in moderate ducts was associated with a high incidence (59%) of long-term echocardiographic shunt patency and a need for repeat intervention for audible residual shunts (32%). Conclusions: Single coil transcatheter occlusion is the treatment of choice for the small duct as most residual shunts will resolve spontaneously. However, long-term shunt persistence after single coil deployment in moderate sized ducts is as frequent as with the Rashkind device. A primary multiple coil approach is advocated if the postcoil aortogram shows residual ductal shunting and if there is persistence of a ductal murmur on auscultation. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [1] Patent ductus arteriosus occlusion by Rashkind umbrella and by detachable coil
    Mahayni, MN
    Pépin-Donat, M
    Saillant, D
    Poinsot, J
    Vaillant, MC
    Chantepie, A
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2002, 95 (05): : 418 - 424
  • [2] Transcatheter occlusion of the ductus arteriosus with the Rashkind umbrella device.
    Piechaud, JF
    Delogu, A
    Kachaner, J
    Iserin, L
    Aggoun, Y
    Giusti, S
    Bonnet, D
    Sidi, D
    ARCHIVES DE PEDIATRIE, 1995, 2 (12): : 1149 - 1155
  • [3] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS BY RASHKIND UMBRELLA DEVICE - FOLLOW-UP RESULTS
    ARORA, R
    KALRA, GS
    NIGAM, M
    KHALILLULAH, M
    AMERICAN HEART JOURNAL, 1994, 128 (03) : 539 - 541
  • [4] Combined use of detachable coil against persistent mechanical hemolysis after transcatheter occlusion using Rashkind umbrella device in adult patient with patent ductus arteriosus
    Murakami, H
    Tsuchihashi, K
    Tomita, H
    Ikeda, R
    Hirata, A
    Ogawa, T
    Nakagawa, M
    Kuroiwa, Y
    Fuse, S
    Shimamoto, K
    HEART AND VESSELS, 1997, 12 (01) : 49 - 51
  • [5] Combined use of detachable coil against persistent mechanical hemolysis after transcatheter occlusion using Rashkind umbrella device in adult patient with patent ductus arteriosus
    Hideyuki Murakami
    Kazufumi Tsuchihashi
    Hideshi Tomita
    Rie Ikeda
    Akifumi Hirata
    Takashi Ogawa
    Motoya Nakagawa
    Yuki Kuroiwa
    Shigeto Fuse
    Kazuaki Shimamoto
    Heart and Vessels, 1997, 12 : 49 - 51
  • [6] Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils
    Tometzki, AJP
    Arnold, R
    Peart, I
    Sreeram, N
    Abdulhamed, JM
    Godman, MJ
    Patel, RG
    Kitchiner, DJ
    BuLock, FA
    Walsh, KP
    HEART, 1996, 76 (06) : 531 - 535
  • [7] Transcatheter closure of the patent ductus arteriosus: A comparative study between occluding coils and the Rashkind umbrella device
    Bulbul, ZR
    Fahey, JT
    Doyle, TP
    Hijazi, ZM
    Hellenbrand, WE
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 39 (04): : 355 - 363
  • [8] Transcatheter occlusion of the patent ductus arteriosus Use of the retrievable coil device
    Johnston, TA
    Stern, HJ
    O'Laughlin, MP
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 46 (04) : 434 - 437
  • [9] Transcatheter closure of the patent ductus arteriosus: Comparison between the Rashkind occluder device and the anterograde Gianturco coils technique
    Galal, O
    deMoor, M
    AlFadley, F
    Hijazi, ZM
    AMERICAN HEART JOURNAL, 1996, 131 (02) : 368 - 373
  • [10] Comparison of Two Transcatheter Device Strategies for Occlusion of the Patent Ductus Arteriosus
    Gudausky, Todd M.
    Hirsch, Russel
    Khoury, Philip R.
    Beekman, Robert H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (05) : 675 - 680