机构:
Univ Molise, Dept Med & Hlth Sci Vincenzo Tiberio, Via G Paolo II Contrada Tappino, I-86100 Campobasso, ItalyUniv Sannio, DING Dept Engn, Piazza Roma 21, I-82100 Benevento, Italy
Ventilated facade;
In-field measurements;
Mediterranean climate;
Grills configuration;
Cavity air-flow;
Thermal behavior;
Energy saving;
ENERGY PERFORMANCE;
WALLS;
TEMPERATURE;
SYSTEMS;
MODEL;
D O I:
10.1016/j.jobe.2022.104608
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
This paper focuses on the experimental analysis of a ventilated facade made of recycled materials, under typical summertime Mediterranean conditions. The test area is around 16 m(2) and it is equipped with several sensors for a complete seasonal characterization of the chimney phenomenon and the thermal performance. Indeed, despite several studies are available in the literature, these are usually based on short monitoring campaign and the experimental installations have limited size. The study introduces a new statistical approach for selecting the daily reference scenarios aimed at the comparison of the thermal field and the ventilation with two degrees of openness of the grids in the air-gap. A seasonal analysis is also developed by means of violin plots constructed in order to study both the real distribution and the statistical indexes of the analyzed parameters. The analysis indicated that the opened channel is always characterized by higher air flow speeds with 75% of monitored values under 0.4 m/s and peak values near 2.0 m/s compared to the semi-closed configuration. In the seasonal analysis, the surface temperature of the insulation has a median values 4.5 degrees C lower than the semi-closed configuration meanwhile the third quartile is respectively 36.5 degrees C and 41.1 degrees C. Considering the temperature differences across the back wall, with the opened configuration, around 25% values indicated an outgoing conductive heat flow meanwhile during the sunniest hours, the median value is 3.3 degrees C in case of opened channel and 7.4 degrees C in the semi-closed one. The proposed method and results could help designers for select the best performing solution for their climatic conditions and researchers to develop more accurate analysis with short and long time-step.
机构:
Univ Fed Ouro Preto, Civil Engn Postgrad Program, Ouro Preto, BrazilUniv Fed Ouro Preto, Civil Engn Postgrad Program, Ouro Preto, Brazil
Souza, L. C. O.
Souza, H. A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Ouro Preto, Dept Control & Automat & Fundamentals Tech, Ouro Preto, BrazilUniv Fed Ouro Preto, Civil Engn Postgrad Program, Ouro Preto, Brazil
Souza, H. A.
Rodrigues, E. F.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Ouro Preto, Dept Control & Automat & Fundamentals Tech, Ouro Preto, BrazilUniv Fed Ouro Preto, Civil Engn Postgrad Program, Ouro Preto, Brazil
机构:
Tech Univ Madrid, Fac Architecture, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, SpainTech Univ Madrid, Fac Architecture, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, Spain
Arce Recatala, Maria
Garcia Morales, Soledad
论文数: 0引用数: 0
h-index: 0
机构:
Tech Univ Madrid, Fac Architecture, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, SpainTech Univ Madrid, Fac Architecture, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, Spain
Garcia Morales, Soledad
van den Bossche, Nathan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Ghent, Fac Engn & Architecture, Ghent, BelgiumTech Univ Madrid, Fac Architecture, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, Spain
机构:
CIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, SpainCIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, Spain
Sanjuan, Cristina
Nuria Sanchez, Maria
论文数: 0引用数: 0
h-index: 0
机构:
CIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, SpainCIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, Spain
Nuria Sanchez, Maria
del Rosario Heras, Maria
论文数: 0引用数: 0
h-index: 0
机构:
CIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, SpainCIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, Spain
del Rosario Heras, Maria
Blanco, Eduardo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Oviedo, EDZE Energia, Gijon 33271, Asturias, SpainCIEMAT, Dept Energy, Energy Efficiency Bldg Res Unit, E-28040 Madrid, Spain