Diagnosis of Amebic Liver Abscess and Amebic Colitis by Detection of Entamoeba histolytica DNA in Blood, Urine, and Saliva by a Real-Time PCR Assay

被引:51
|
作者
Haque, Rashidul [2 ]
Kabir, Mamun [2 ]
Noor, Zannatun [2 ]
Rahman, S. M. Mazidur [2 ]
Mondal, Dinesh [2 ]
Alam, Faisal [3 ]
Rahman, Intekhab [3 ]
Al Mahmood, Abdullh [4 ]
Ahmed, Nooruddin [4 ]
Petri, William A., Jr. [1 ]
机构
[1] Univ Virginia Hlth Syst, Div Infect Dis & Int Hlth, Charlottesville, VA 22908 USA
[2] Int Ctr Diarrhoeal Dis Res, Dhaka 1000, Bangladesh
[3] Rajshahi Med Coll, Rajshahi, Bangladesh
[4] Bangabandhu Sheikh Mujib Med Univ, Dhaka, Bangladesh
关键词
POLYMERASE-CHAIN-REACTION; ANTIGEN-DETECTION; ANTIBODY-RESPONSE; LECTIN ANTIGEN; INFECTION; DISPAR; DIFFERENTIATION; AMPLIFICATION; PREVALENCE; SAMPLES;
D O I
10.1128/JCM.00152-10
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The noninvasive diagnosis of amebic liver abscess is challenging, as most patients at the time of diagnosis do not have a concurrent intestinal infection with Entamoeba histolytica. Fecal testing for E. histolytica parasite antigen or DNA is negative in most patients. A real-time PCR assay was evaluated for detection of E. histolytica DNA in blood, urine, and saliva samples from amebic liver abscess as well as amebic colitis patients in Bangladesh. A total of 98 amebic liver abscess and 28 amebic colitis patients and 43 control subjects were examined. The real-time PCR assay detected E. histolytica DNA in 49%, 77%, and 69% of blood, urine, and saliva specimens from the amebic liver abscess patients. For amebic colitis the sensitivity of the real-time PCR assay for detection of E. histolytica DNA in blood, urine, and saliva was 36%, 61%, and 64%, respectively. All blood, urine, and saliva samples from control subjects were negative by the real-time PCR assay for E. histolytica DNA. When the real-time PCR assay results of the urine and saliva specimens were taken together (positive either in urine or saliva), the real-time PCR assay was 97% and 89% sensitive for detection of E. histolytica DNA in liver abscess and intestinal infection, respectively. We conclude that the detection of E. histolytica DNA in saliva and urine could be used as a diagnostic tool for amebic liver abscess.
引用
收藏
页码:2798 / 2801
页数:4
相关论文
共 50 条
  • [21] Real-time PCR assay in differentiating Entamoeba histolytica, Entamoeba dispar, and Entamoeba moshkovskii infections in Orang Asli settlements in Malaysia
    Lau, Yee Ling
    Anthony, Claudia
    Fakhrurrazi, Siti Aminah
    Ibrahim, Jamaiah
    Ithoi, Init
    Mahmud, Rohela
    PARASITES & VECTORS, 2013, 6
  • [22] Detection of Entamoeba histolytica DNA in the Saliva of Amoebic Liver Abscess Patients Who Received Prior Treatment with Metronidazole
    Khairnar, Krishna
    Parija, Subhash Chandra
    JOURNAL OF HEALTH POPULATION AND NUTRITION, 2008, 26 (04) : 418 - 425
  • [23] Real-time PCR assay in differentiating Entamoeba histolytica, Entamoeba dispar, and Entamoeba moshkovskii infections in Orang Asli settlements in Malaysia
    Yee Ling Lau
    Claudia Anthony
    Siti Aminah Fakhrurrazi
    Jamaiah Ibrahim
    Init Ithoi
    Rohela Mahmud
    Parasites & Vectors, 6
  • [24] EVALUATION OF A NEW SINGLE-TUBE MULTIPROBE REAL-TIME PCR FOR DIAGNOSIS OF ENTAMOEBA HISTOLYTICA AND ENTAMOEBA DISPAR
    Liang, Shih-Yu
    Hsia, Kan-Tai
    Chan, Yun-Hsien
    Fan, Chia-Kwung
    Jiang, Donald Dah-Shyong
    Landt, Olfert
    Ji, Dar-Der
    JOURNAL OF PARASITOLOGY, 2010, 96 (04) : 793 - 797
  • [25] Real-time duplex PCR detection of Giardia lamblia, Cryptosporidium parvum, and Entamoeba histolytica in feces
    Bergmans, A. M. C.
    van Keuten, P. H. J.
    Andriesse, G. I.
    ACTA CLINICA BELGICA, 2007, 62 (06) : 455 - 455
  • [26] Evaluation of a Novel Commercial Real-Time PCR Assay for the Simultaneous Detection of Cryptosporidium spp., Giardia duodenalis, and Entamoeba histolytica
    Dashti, Alejandro
    Alonso, Henar
    Escolar-Minana, Cristina
    Koster, Pamela C.
    Bailo, Begona
    Carmena, David
    Gonzalez-Barrio, David
    MICROBIOLOGY SPECTRUM, 2022, 10 (03):
  • [27] Evaluation of factors affecting real-time PCR performance for diagnosis of Entamoeba histolytica and Entamoeba dispar in clinical stool samples
    Forsell, Joakim
    Koskiniemi, Satu
    Hedberg, Ida
    Edebro, Helen
    Evengard, Birgitta
    Granlund, Margareta
    JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 : 1053 - 1062
  • [28] Detection of Leishmania infantum DNA by real-time PCR in saliva of dogs
    Cantos-Barreda, Ana
    Escribano, Damian
    Siriyasatien, Padet
    Ceron, Jose J.
    Carmen Thomas, M.
    Afonso-Lehmann, Raquel N.
    Lopez, Manuel C.
    Bernal, Luis J.
    Phumee, Atchara
    Lubas, George
    Martinez-Subiela, Silvia
    COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 2020, 73
  • [29] Development and Preliminary Application of a Triplex Real-Time Quantitative PCR Assay for the Simultaneous Detection of Entamoeba histolytica, Giardia lamblia, and Cryptosporidium parvum
    Zhang, Yaoguang
    Chen, Jian
    Pan, Hao
    Ma, Xiaojiang
    Jiang, Li
    Zhu, Qian
    Wu, Huanyu
    Wang, Zhenyu
    FRONTIERS IN MICROBIOLOGY, 2022, 13
  • [30] Rapid diagnosis of candidaemia by real-time PCR detection of Candida DNA in blood samples
    Wellinghausen, Nele
    Siegel, Dunja
    Winter, Juliane
    Gebert, Susanne
    JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 58 (08) : 1106 - 1111