The role of inferior vena cava diameter in the differential diagnosis of dyspneic patients; best sonographic measurement method?

被引:20
|
作者
Yamanoglu, Adnan [1 ]
Yamanoglu, Nalan G. Celebi [2 ]
Parlak, Ismet [3 ]
Pinar, Pelin [3 ]
Tosun, Ali [4 ]
Erkuran, Burak [3 ]
Akgur, Alper [5 ]
Siliv, Neslihan Satilmis [3 ]
机构
[1] Haseki Training & Res Hosp, TR-34096 Istanbul, Turkey
[2] Beykoz State Hosp, Istanbul, Turkey
[3] Izmir Bozyaka Training & Res Hosp, Izmir, Turkey
[4] Sanliurfa Mehmet Akif Ersoy Training & Res Hosp, Sanliurfa, Turkey
[5] Gaziantep Dr Ersin Arslan State Hosp, Gaziantep, Turkey
来源
关键词
CONGESTIVE-HEART-FAILURE; HAND-CARRIED ULTRASOUND; NATRIURETIC PEPTIDE; ECHOCARDIOGRAPHY; MANAGEMENT;
D O I
10.1016/j.ajem.2014.12.032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We aimed to determine the role of inferior vena cava (IVC) diameter in making a differentiation between dyspnea of cardiac (acute heart failure [AHF]) and pulmonary origin. We also attempted to determine the best sonographic method for the measurement of IVC diameter. Methods: This prospective observational study was conducted at the intensive care unit of the emergency department of a training and research hospital. This study enrolled patients with the main symptom of dyspnea who were categorized into 2 groups, cardiac dyspnea and pulmonary dyspnea groups, based on the final diagnosis. All patients underwent sonographic measurement of minimum and maximum diameters of IVC, and the caval index (CI) was calculated in both M-mode and B-mode. The sensitivity, specificity, and likelihood ratios (LR) of the IVC values for the differentiation of the 2 groups were calculated. Results: This study included a total of 74 patients with a mean age of 72.8 years. Thirty-two patients had dyspnea of cardiac origin, and 42 patients had dyspnea of pulmonary origin. The IVC diameter measured with B-mode during inspiration (B-mode i) was the most successful method for differentiation of the 2 groups. B-mode i values greater than 9 mm predicted dyspnea of cardiac origin with a sensitivity of 84.4% and a specificity of 92.9% (+ LR: 11.8, LR: 0.16). Conclusion: Sonographic assessment of the IVC diameter may be used as a rapid, readily, nonexpensive, complication-free, and reproducible technique for the differentiation of cardiac and pulmonary causes of dyspnea. B-mode i measurement may be more successful in the differentiation of dyspnea compared with other IVC diameters and calculations. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [11] Sonographic measurement of the inferior vena cava as a marker of blood loss
    Lyon, M
    Blaivas, M
    Brannam, L
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2005, 23 (01): : 45 - 50
  • [12] SONOGRAPHIC DIAGNOSIS OF INFERIOR VENA-CAVA THROMBOSIS IN THE PUERPERIUM
    TROESTER, U
    HOFMANN, H
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1988, 48 (12) : 902 - 903
  • [13] SONOGRAPHIC DIAGNOSIS OF CALCIFIED THROMBUS OF THE INFERIOR VENA-CAVA
    CUNAT, JS
    MORRISON, SC
    FLETCHER, BD
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (650): : 160 - 162
  • [14] Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location
    Naghipour, Bahman
    Faridaalaee, Gholamreza
    EMERGENCY, 2016, 4 (02): : 83 - 87
  • [15] Diagnostic accuracy of inferior vena cava evaluation in the diagnosis of acute heart failure among dyspneic patients
    Sforza, Alfonso
    Carlino, Maria Viviana
    Guarino, Mario
    Fucile, Ilaria
    De Luca, Nicola
    Mancusi, Costantino
    MONALDI ARCHIVES FOR CHEST DISEASE, 2020, 90 (04) : 704 - 707
  • [16] Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
    Hoffman, Maximilian
    Convissar, David L.
    Meng, Marie-Louise
    Montgomery, Sean
    Bronshteyn, Yuriy S.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (191):
  • [17] Role of inferior vena cava ultrasound in diagnosis of shock in patients with trauma
    Youssif, Khalid Y. A.
    El Sayed, Zaynab M.
    Ali, Mohammed A.
    Moghazy, Amr M.
    EGYPTIAN JOURNAL OF SURGERY, 2020, 39 (01): : 194 - 198
  • [18] Inferior Vena Cava Measurement with Ultrasound: What Is the Best View and Best Mode?
    Finnerty, Nathan M.
    Panchal, Ashish R.
    Boulger, Creagh
    Vira, Amar
    Bischof, Jason J.
    Amick, Christopher
    Amick, Christopher
    Way, David P.
    Bahner, David P.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2017, 18 (03) : 496 - 501
  • [19] Sonographic Assessment of Inferior Vena Cava Diameter In Assessing Volume Status In The Emergency Department
    Agarwal, D.
    Soucy, Z.
    Chandra, S.
    ANNALS OF EMERGENCY MEDICINE, 2011, 58 (04) : S311 - S312
  • [20] Correlation of sonographic inferior vena cava and aorta diameter ratio with dehydration in Nigerian children
    Adewumi, A. A.
    Braimoh, K. T.
    Adesiyun, O. A. M.
    Ololu-Zubair, H. T.
    Idowu, B. M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (07) : 950 - 956