A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

被引:8
|
作者
Lin, Ruixing [1 ]
Xu, Lin [1 ]
Zheng, Xian [2 ]
机构
[1] State Grid Sichuan Elect Power Res Inst, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Elect Engn & Informat Technol, Chengdu, Sichuan, Peoples R China
关键词
D O I
10.1088/1757-899X/322/7/072038
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] An active power filter with harmonic detection method based on recursive DFT
    Srianthumrong, S
    Sangwongwanich, S
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 127 - 132
  • [32] An artificial neural network based method for harmonic detection in power system
    He Na
    Huang Lina
    Wu Jian
    Xu Dianguo
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 456 - 461
  • [33] A weak harmonic detection method for a power system based on chaos theory
    Sun S.
    Qi X.
    Yuan Z.
    Li Z.
    Tang X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (15): : 76 - 86
  • [34] Islanding detection method based on active power filter and harmonic compensation
    Dong L.
    Tian H.
    Xiao F.
    Han J.
    Liao X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (04): : 133 - 138
  • [35] Localization of Harmonic Sources in a Power System with Use of the Generalized Localization Rate
    Wilkosz, Kazimierz
    2009 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION (EPQU 2009), 2009, : 301 - 306
  • [36] Harmonic analysis method based on multi-harmonic source in power system
    Xia, Xiangyang
    Li, Lingli
    Yu, Hong
    Deng, Tanyu
    Luo, Jiping
    Huang, Hai
    Wang, Huan
    Xiang, Min
    Liu, Qifan
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2014, 45 (12): : 4239 - 4244
  • [37] A "critical impedance" - based method for identifying harmonic sources
    Li, C
    Xu, WS
    Tayjasanant, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 671 - 678
  • [38] A "critical impedance" based method for identifying harmonic sources
    Xu, WS
    Li, C
    Tayjasanant, T
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 917 - 917
  • [39] Performance Comparison of Harmonic Filters in an Industrial Power System for Harmonic Distortion Reduction
    Mitiku, Estifanos Dagnew
    Aduye, Gebrie Teshome
    Rahman, Abdul
    Abuhay, Mahilet Mentesinot
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (03): : 50 - 53
  • [40] EFFECT OF HARMONIC DISTORTION IN USE OF VIBRATORY SURFACE SOURCES
    SERIFF, AJ
    KIM, WH
    GEOPHYSICS, 1970, 35 (02) : 234 - &