This article reports the design and development of ran ECG simulator, intended for use in the testing, calibration and maintenance of electrocardiographic equipment. It generates a lead II signal having a profile that varies with heart rate in a manner which reflects the true in vivo variation. Facilities are provided for user adjustment of heart rate, signal amplitude, QRS complex up-slope, and the relative amplitudes of the P-wave and T-wave. The heart mate can be set within the range 30-200 beats min(-1) in steps of 1 beat min(-1). The amplitude of the QRS complex can be adjusted from 0.1-20 mV in 0.1 mV steps, while its tap-slope can be set between 10 and 50 ms with a 1 ms resolution. The amplitude of the P-wave can be varied from 5-40% and that of the T-wave,from 10-80% of the amplitude of the QRS complex with a 1% resolution.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 50 条
  • [41] An Accurate Congestion Control Mechanism in Programmable Network
    JinhaoJiang
    YueZhang
    2019 IEEE 9TH ANNUAL COMPUTING AND COMMUNICATION WORKSHOP AND CONFERENCE (CCWC), 2019, : 673 - 677
  • [42] DESIGN OF PROGRAMMABLE GAIN AMPLIFIER WITH ACCURATE GAIN
    Liu, Miao
    Peng, Xiaohong
    Wang, Jinhui
    Wu, Yanwei
    2014 12TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT), 2014,
  • [43] PROGRAMMABLE TIMER PROVIDES ACCURATE INTERVAL MEASUREMENTS
    CARLIN, FH
    HOWARD, JA
    COMPUTER DESIGN, 1979, 18 (05): : 213 - &
  • [44] Is accurate recording of the ECG surface Laplacian feasible?
    Geselowitz, DB
    Ferrara, JE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (04) : 377 - 381
  • [45] Learning to Automatically Generate Accurate ECG Captions
    Bartels, Mathieu G. G.
    Najdenkoska, Ivona
    van de Leur, Rutger R.
    Sammani, Arjan
    Taha, Karim
    Knigge, David M.
    Doevendans, Pieter A.
    Worring, Marcel
    van Es, Rene
    INTERNATIONAL CONFERENCE ON MEDICAL IMAGING WITH DEEP LEARNING, VOL 172, 2022, 172 : 86 - 102
  • [46] Accurate wavelet thresholding method for ECG signals
    Yu, Kaimin
    Feng, Lei
    Chen, Yunfei
    Wu, Minfeng
    Zhang, Yuanfang
    Zhu, Peibin
    Chen, Wen
    Wu, Qihui
    Hao, Jianzhong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2024, 169
  • [47] AGOCS - Accurate Google Cloud Simulator Framework
    Sliwko, Leszek
    Getov, Vladimir
    2016 INT IEEE CONFERENCES ON UBIQUITOUS INTELLIGENCE & COMPUTING, ADVANCED & TRUSTED COMPUTING, SCALABLE COMPUTING AND COMMUNICATIONS, CLOUD AND BIG DATA COMPUTING, INTERNET OF PEOPLE, AND SMART WORLD CONGRESS (UIC/ATC/SCALCOM/CBDCOM/IOP/SMARTWORLD), 2016, : 550 - 558
  • [48] Accurate ECG monitoring by Gaussian feature streaming
    Galli, Alessandra
    Giorgi, Giada
    Narduzzi, Claudio
    MEASUREMENT, 2023, 223
  • [49] Efficient and accurate simulator for Rayleigh and Rician fading
    Junfeng Wang
    Xiurong Ma
    Jianfu Teng
    Yue Cui
    Transactions of Tianjin University, 2012, 18 (4) : 243 - 247
  • [50] CYCLE ACCURATE SIMULATOR GENERATION USING HARMLESS
    Kassem, Rola
    Briday, Mikael
    Bechennec, Jean-Luc
    Trinquet, Yvon
    Savaton, Guillaume
    MESM 2009: 10TH MIDDLE EASTERN SIMULATION MULTICONFERENCE, 2009, : 18 - +