Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy

被引:5
|
作者
Seibert, James Anthony [1 ]
机构
[1] Univ Calif Davis Hlth, Dept Radiol, 4860 Y St,Suite 3100, Sacramento, CA 95817 USA
来源
HEALTH PHYSICS | 2019年 / 116卷 / 02期
关键词
National Council on Radiation Protection and Measurements; fluoroscopy; radiation dose; x rays; PERFORMANCE;
D O I
10.1097/HP.0000000000001028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent advances in digital detector technology for medical radiography and fluoroscopy have resulted in improved workflow efficiency, operational flexibility, image quality, and diagnostic accuracy. This is attributed to the implementation of portable flat-panel x-ray detector devices able to provide real-time readout, processing, and display of medical images. As a result, digital radiography flat-panel detectors are rapidly replacing computed radiography passive detectors for projection imaging exams and image intensifier detectors for dynamic fluoroscopy exams. Advanced exam capabilities now include digital tomosynthesis and dual-energy radiography; the former is based on rapid acquisition of multiple angle-dependent image projections to synthesize tomographic slabs at selectable depths within the patient, and the latter is based on rapid back-to-back acquisition of the same anatomy at low and high x-ray energies to generate separate soft tissue and bone images. In both situations, superimposition of anatomy is reduced or eliminated, with the possibility of enhanced diagnostic confidence. Increased x-ray absorption efficiency and lower electronic noise of digital radiography detectors compared to computed radiography detectors enable equal image quality at lower patient dose; however, because of a disconnect between image appearance and radiation dose, lower patient dose is not always achieved. Education, training, and implementation of standards such as the International Electrotechnical Commission 62494-1 Digital Radiography Exposure Index are needed to ensure image quality at the lowest appropriate radiation dose. The National Council on Radiation Protection and Measurements can contribute to radiation responsibility in medical imaging by providing guidance on use of digital radiography, including recommendations for acquisition protocols and exposure index standards, for development of radiographic exam diagnostic reference levels, and for oversight of retake and reject analysis.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 50 条
  • [31] X-ray phase radiography and tomography with grating interferometry and the reverse projection technique
    Wang, Zhili
    Gao, Kun
    Ge, Xin
    Wu, Zhao
    Chen, Heng
    Wang, Shenghao
    Zhu, Peiping
    Yuan, Qingxi
    Huang, Wanxia
    Zhang, Kai
    Wu, Ziyu
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (49)
  • [32] Gated Proton Imaging Using Fiducial Marker and X-Ray Fluoroscopy
    Tanaka, S.
    Miyamoto, N.
    Shimada, Y.
    Yoshimura, T.
    Takao, S.
    Matsuo, Y.
    Shimizu, S.
    Matsuura, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E462 - E462
  • [33] Monoplane Stereoscopic Imaging Method for Inverse Geometry X-ray Fluoroscopy
    Tomkowiak, Michael T.
    Van Lysel, Michael S.
    Speidel, Michael A.
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [34] DUAL-ENERGY PROJECTION RADIOGRAPHY USING CONDENSER X-RAY GENERATOR AND DIGITAL RADIOGRAPHY APPARATUS
    NISHITANI, H
    UMEZU, Y
    OGAWA, K
    YUZURIHA, H
    TANAKA, H
    MATSUURA, K
    RADIOLOGY, 1986, 161 (02) : 533 - 535
  • [35] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [36] X-RAY RADIOGRAPHY OF COAL
    VINOPAL, R
    JOURNAL OF SEDIMENTARY PETROLOGY, 1979, 49 (02): : 483 - 486
  • [37] Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging
    Bernhard Stimpel
    Christopher Syben
    Tobias Würfl
    Katharina Breininger
    Philip Hoelter
    Arnd Dörfler
    Andreas Maier
    Scientific Reports, 9
  • [38] Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging
    Stimpel, Bernhard
    Syben, Christopher
    Wuerfl, Tobias
    Breininger, Katharina
    Hoelter, Philip
    Doerfler, Arnd
    Maier, Andreas
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [39] X-RAY PROTECTION IN INDUSTRIAL FLUOROSCOPY
    HENNY, GC
    RADIOLOGY, 1946, 46 (01) : 66 - 69
  • [40] X-RAY FLUOROSCOPY FOR AIRCRAFT INSPECTION
    不详
    METAL CONSTRUCTION AND BRITISH WELDING JOURNAL, 1972, 4 (09): : 350 - &