Contactless Carotid Pulse Measurement Using Continuous Wave Radar

被引:0
|
作者
Shi, Kilin [1 ]
Schellenberger, Sven [2 ]
Steigleder, Tobias [3 ,4 ]
Michler, Fabian [1 ]
Lurz, Fabian [1 ]
Weigel, Robert [1 ]
Koelpin, Alexander [2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Inst Elect Engn, D-91058 Erlangen, Germany
[2] Brandenburg Tech Univ Cottbus, Chair Elect & Sensor Syst, D-03046 Cottbus, Germany
[3] Univ Klinikum Erlangen, Dept Palliat Care, D-91054 Erlangen, Germany
[4] Univ Klinikum Erlangen, Dept Neurol, D-91054 Erlangen, Germany
关键词
biomedical monitoring; biomedical signal analysis; cardiovascular system; cw radar; medical sensors; radar signal analysis; ultrasound; MYOCARDIAL-INFARCTION; MEDIA THICKNESS; STROKE; STENOSIS; INTIMA; RISK;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiovascular diseases are one of the major causes of death. Regular checkups and preventive actions can drastically help reducing fatal incidences. This can be achieved by monitoring the carotid artery or rather the carotid pulse signal. Commonly, ultrasound devices are used for that purpose. However, these devices are costly, mostly stationary and their usage requires training and experience. This paper investigates the possible usage of radar systems as a contactless and low-cost alternative for carotid pulse measurements. Theoretical investigations reveal a linear relationship between the measurands of both devices and synchronous recordings from three test persons further confirm the feasibility of using radar systems as a potential device for monitoring cardiovascular diseases.
引用
收藏
页码:569 / 571
页数:3
相关论文
共 50 条
  • [21] Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar
    Buxi, Dilpreet
    Redout, Jean-Michel
    Yuce, Mehmet Rasit
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) : 917 - 927
  • [22] EFFECT OF PULSE WIDTH ON RADAR MEASUREMENT OF OCEAN WAVE HEIGHT
    YOUNG, TY
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1974, 37 (06) : 833 - 848
  • [23] Contactless multiscale measurement of cardiac motion using biomedical radar sensor
    Qiao, Jia-hao
    Qi, Fu-gui
    Liang, Fu-lai
    Ma, Jin
    Lv, Hao
    Yu, Xiao
    Xue, Hui-jun
    An, Qiang
    Yan, Ke-ding
    Shi, Ding
    Qiao, Yong-hui
    Wang, Jian-qi
    Zhang, Yang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [24] Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method
    Tang, Chieh-Ju
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Huang, Chih-Chung
    ULTRASONICS, 2020, 102
  • [25] Contactless Electrocardiogram Monitoring With Millimeter Wave Radar
    Chen, Jinbo
    Zhang, Dongheng
    Wu, Zhi
    Zhou, Fang
    Sun, Qibin
    Chen, Yan
    IEEE TRANSACTIONS ON MOBILE COMPUTING, 2024, 23 (01) : 270 - 285
  • [26] Blind Signal Separation for Array Radar Measurement Using Mathematical Model of Pulse Wave Propagation
    Sakamoto, Takuya
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2022, E105B (08) : 981 - 989
  • [27] Study of Continuous Wave Radar for Human Motion Characteristics Measurement
    Qiu, Zhao-kun
    Li, Dong-ze
    Jiang, Wei-dong
    2010 IEEE 10TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS (ICSP2010), VOLS I-III, 2010, : 1078 - 1081
  • [28] A Novel Contactless Concentration Evaluation Technique Using Millimeter-Wave Radar
    Cao, Jie
    Li, Yuchen
    Liu, Jingtao
    Gu, Changzhan
    2024 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY, ICMMT, 2024,
  • [29] A Double Sideband Continuous Wave Radar for Monitoring Carotid Artery Wall Movements
    Pisa, Stefano
    Pittella, Erika
    Piuzzi, Emanuele
    Testa, Orlandino
    Cicchetti, Renato
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 1003 - 1006
  • [30] Pulse Wave Velocity Measurement in Healthy and Diseased Carotid Arteries In Vivo
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,