Predictability of residual astigmatism after implantation of posterior chamber toric lenses

被引:0
|
作者
Mies, D. [1 ,2 ]
Klink, T.
Eisenbarth, W. [1 ,2 ]
Meyer, L. M. [2 ]
机构
[1] Hsch Angew Nat Wissensch, Munich, Germany
[2] Augenklin Herzog Carl Theodor, Nymphenburger Str 43, D-80335 Munich, Germany
来源
OPHTHALMOLOGE | 2018年 / 115卷 / 01期
关键词
Cataract surgery; Refractive surgery; Astigmatism; Tecnis (R) ZCT toric intraocular lenses; Residual astigmatism; INTRAOCULAR-LENS; CORNEAL ASTIGMATISM; CATARACT-SURGERY; PERFORMANCE;
D O I
10.1007/s00347-017-0474-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The objective of the study was to examine the predictability of residual astigmatism after cataract surgery and implantation of the posterior chamber aspheric toric lens TECNISA (R) ZCT, Abott Medical Optic (Ettlingen, Deutschland). The retrospective study included a total of 88 patient eyes undergoing a cataract operation with a toric lens implantation between March 2014 and October 2015. The inclusion criteria were a regular astigmatism of at least 0.75 dpt. Posterior chamber toric lenses (model Tecnis ZCT) were exclusively implanted. Post-surgery check-ups were performed after 1 day, 1 month and 2 months. Main study outcome was best-corrected visual acuity (BCVA), spherical and astigmatic aberration and the difference between expected and actual residual astigmatism after cataract surgery. The median reduction of corneal astigmatism was from -2.50 dpt (+/- 1.06 dpt) to -0.75 dpt (+/- 0.51 dpt) (p <= 0.05). The median BCVA increased from 0.37 logMAR (+/- 0.25 logMAR) before surgery to 0.09 logMAR (+/- 0.10 logMAR) after surgery. The spherical equivalent was reduced from +3.50 dpt (+/- 1.11 dpt) (presurgery) to -0.56 dpt (+/- 0.51 dpt) (postsurgery) in hyperopic patients and from -2.44 dpt (+/- 3.03 dpt) to -0.69 dpt (+/- 0.81 dpt) in myopic patients. By using the power vector analysis no significant deviation from the expected target values was observed; however, the median discrepancy between the expected and actual residual astigmatism was -0.50 dpt despite a surgical orientation of the intraocular lens (IOL) within 5A degrees of the desired axis. The IOL showed a median rotation of 3.00A degrees (+/- 4.46A degrees). Implantation of the aspheric toric intraocular lens Tecnis ZCT is a predictable, effective and reproducible tool in cataract surgery to account for regular corneal astigmatis; however, despite an optimal surgical orientation of the toric IOL, a small and rarely a large discrepancy might occur between expected and actual residual astigmatism.
引用
收藏
页码:12 / 20
页数:9
相关论文
共 50 条
  • [41] Implantation of Toric Phakic Intraocular Lenses To Treat Astigmatism in Children with Neurodevelopmental Disorders
    Faron, Nicholas
    Tychsen, Lawrence
    Hoekel, James R.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [42] FLEXURE AND RESIDUAL ASTIGMATISM WITH POLYCON AND POLY(METHYL METHACRYLATE LENSES ON TORIC CORNEAS
    HARRIS, MG
    KADOYA, J
    NOMURA, J
    WONG, V
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1982, 59 (03): : 263 - 266
  • [43] Toric intraocular lenses and correction of astigmatism
    Viestenz, Arne
    Walter, S.
    Viestenz, Anja
    Behrens-Baumann, W.
    Langenbucher, A.
    [J]. OPHTHALMOLOGE, 2007, 104 (07): : 620 - 627
  • [44] Correction of corneal astigmatism with toric lenses
    Langenbucher, A.
    Viestenz, A.
    Szentmary, N.
    Viestenz, A.
    Eppig, T.
    Seitz, B.
    [J]. OPHTHALMOLOGE, 2010, 107 (02): : 189 - 200
  • [45] Effects of Calculator with Posterior Corneal Astigmatism on Toric Intraocular Lens Selection and Simulated Residual Astigmatism
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Seki, Mariko
    Nakano, Shinichiro
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [46] Cylindrical and toric lenses and the correction of astigmatism
    Dufour
    [J]. COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1904, 56 : 729 - 730
  • [47] Astigmatism correction: Laser in situ keratomileusis versus posterior chamber collagen copolymer toric phakic intraocular lens implantation
    Hasegawa, Asato
    Kojima, Takashi
    Isogai, Naoki
    Tamaoki, Akeno
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 574 - 581
  • [48] APPARENT ACCOMMODATION IN PSEUDOPHAKIC EYES AFTER IMPLANTATION OF POSTERIOR CHAMBER INTRAOCULAR LENSES
    NAKAZAWA, M
    OHTSUKI, K
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (04) : 435 - 438
  • [49] Optimum form of posterior chamber intraocular lenses to minimize aberrational astigmatism
    Takei, K
    Hommura, S
    Okajima, H
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 1995, 39 (04) : 390 - 401