Physician Procedure Volume and Complications of Cardioverter-Defibrillator Implantation

被引:78
|
作者
Freeman, James V. [1 ]
Wang, Yongfei [2 ]
Curtis, Jeptha P. [2 ]
Heidenreich, Paul A. [3 ]
Hlatky, Mark A. [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[2] Yale Univ, Sch Med, New Haven, CT USA
[3] VA Palo Alto Hlth Care Syst, Palo Alto, CA USA
关键词
defibrillation; epidemiology; morbidity; mortality; PERCUTANEOUS CORONARY INTERVENTIONS; ACUTE MYOCARDIAL-INFARCTION; OPERATOR VOLUME; HOSPITAL VOLUME; ANGIOPLASTY VOLUME; UNITED-STATES; PACEMAKER-IMPLANTATION; OUTCOMES; MORTALITY; ASSOCIATION;
D O I
10.1161/CIRCULATIONAHA.111.046995
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The outcomes of procedures are often better when they are performed by more experienced physicians. We assessed whether the rate of complications after implantable cardioverter-defibrillator (ICD) placement varied with the volume of procedures a physician performed. Methods and Results-We studied 356 515 initial ICD implantations in the National Cardiovascular Data Registry-ICD Registry, performed by 4011 physicians in 1463 hospitals. We examined the relationship between physician annual ICD implantation volume and in-hospital complications, using hierarchical logistic regression to adjust for patient characteristics, implanting physician certification, hospital characteristics, hospital annual procedure volume, and the clustering of patients within hospitals and by physician. We repeated this analysis for ICD subtypes: single chamber, dual chamber, and biventricular. There were 10 994 patients (3.1%) with a complication after ICD implantation, and 1375 died (0.39%). The complication rate decreased with increasing physician procedure volume from 4.6% in the lowest quartile to 2.9% in the highest quartile (P<0.0001), and the mortality rate decreased from 0.72% to 0.36% (P<0.0001). The inverse relationship between physician procedure volume and complications remained significant after adjusting for patient, physician, and hospital characteristics (OR 1.55 for complications in lowest-volume quartile compared with highest; 95% confidence interval, 1.34-1.79; P<0.0001). This inverse relationship was independent of physician specialty and of hospital volume, was consistent across ICD subtypes, and was also evident for in-hospital mortality. Conclusion-Physicians who implant more ICDs have lower rates of procedural complications and in-hospital mortality, independent of hospital procedure volume, physician specialty, and ICD type. (Circulation. 2012;125:57-64.)
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [21] Implantation of cardioverter-defibrillator: Effects on shoulder function
    Diemberger, Igor
    Pegreffi, Francesco
    Mazzotti, Andrea
    Foschi, Elia
    Martignani, Cristian
    Belli, Guido
    Biffi, Mauro
    Ziacchi, Matteo
    Branzi, Angelo
    Grigioni, Francesco
    Latessa, Pasqualino Maietta
    Porcellini, Giuseppe
    Tentoni, Claudio
    Boriani, Giuseppe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (01) : 294 - 299
  • [22] SUBDIAPHRAGMATIC IMPLANTATION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR GENERATOR
    OBADIA, JF
    CLAUDEL, JP
    RESCIGNO, G
    KIRKORIAN, G
    HERCULE, C
    CHASSIGNOLLE, JF
    TOUBOUL, P
    ANNALS OF THORACIC SURGERY, 1995, 59 (01): : 239 - 241
  • [23] Implantation of a cardioverter-defibrillator in a patient with cardiac amyloidosis
    Ben LC Wright
    Andrew A Grace
    Hugh JB Goodman
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 : 110 - 114
  • [24] Avoiding implantation of a cardioverter-defibrillator by bridging with wearable defibrillator vest
    Klein, Norbert
    Kuntz, Thomas
    Dhein, Stefan
    HERZ, 2021, 46 (02) : 172 - 177
  • [25] INFECTIOUS COMPLICATIONS OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEMS
    SPINLER, SA
    FOOTE, EF
    CONNORS, JE
    RATNASABAPATHI, D
    MARCHLINSKI, FE
    CIRCULATION, 1992, 86 (04) : 451 - 451
  • [26] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - APPEARANCE AND COMPLICATIONS
    LURIE, AL
    UDOFF, EJ
    REID, PJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (04) : 723 - 725
  • [27] Patient Perceptions, Physician Communication, and the Implantable Cardioverter-Defibrillator
    Hauptman, Paul J.
    Chibnall, John T.
    Guild, Camelia
    Armbrecht, Eric S.
    JAMA INTERNAL MEDICINE, 2013, 173 (07) : 571 - 577
  • [28] Subpectoral Cardioverter-Defibrillator Implantation Using a Lateral Approach
    Xenophon F. Costeas
    Panayotis G. Strembelas
    Demetrios X. Markou
    Christodoulos I. Stefanadis
    Pavlos K. Toutouzas
    Journal of Interventional Cardiac Electrophysiology, 2000, 4 : 611 - 619
  • [29] A subcutaneous implantable cardioverter-defibrillator - the first implantation in Poland
    Kaczmarek, Krzysztof
    Zwolinski, Radoslaw
    Bartczak, Karol
    Ptaszynski, Pawel
    Wranicz, Jerzy Krzysztof
    Kardiologia Polska, 2015, 73 (01) : 62 - 62
  • [30] Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-Defibrillator
    Al-Mohaissen, Maha A.
    Chan, Kwan Leung
    CURRENT CARDIOLOGY REPORTS, 2013, 15 (05)