Physician Procedure Volume and Complications of Cardioverter-Defibrillator Implantation

被引:78
|
作者
Freeman, James V. [1 ]
Wang, Yongfei [2 ]
Curtis, Jeptha P. [2 ]
Heidenreich, Paul A. [3 ]
Hlatky, Mark A. [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[2] Yale Univ, Sch Med, New Haven, CT USA
[3] VA Palo Alto Hlth Care Syst, Palo Alto, CA USA
关键词
defibrillation; epidemiology; morbidity; mortality; PERCUTANEOUS CORONARY INTERVENTIONS; ACUTE MYOCARDIAL-INFARCTION; OPERATOR VOLUME; HOSPITAL VOLUME; ANGIOPLASTY VOLUME; UNITED-STATES; PACEMAKER-IMPLANTATION; OUTCOMES; MORTALITY; ASSOCIATION;
D O I
10.1161/CIRCULATIONAHA.111.046995
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The outcomes of procedures are often better when they are performed by more experienced physicians. We assessed whether the rate of complications after implantable cardioverter-defibrillator (ICD) placement varied with the volume of procedures a physician performed. Methods and Results-We studied 356 515 initial ICD implantations in the National Cardiovascular Data Registry-ICD Registry, performed by 4011 physicians in 1463 hospitals. We examined the relationship between physician annual ICD implantation volume and in-hospital complications, using hierarchical logistic regression to adjust for patient characteristics, implanting physician certification, hospital characteristics, hospital annual procedure volume, and the clustering of patients within hospitals and by physician. We repeated this analysis for ICD subtypes: single chamber, dual chamber, and biventricular. There were 10 994 patients (3.1%) with a complication after ICD implantation, and 1375 died (0.39%). The complication rate decreased with increasing physician procedure volume from 4.6% in the lowest quartile to 2.9% in the highest quartile (P<0.0001), and the mortality rate decreased from 0.72% to 0.36% (P<0.0001). The inverse relationship between physician procedure volume and complications remained significant after adjusting for patient, physician, and hospital characteristics (OR 1.55 for complications in lowest-volume quartile compared with highest; 95% confidence interval, 1.34-1.79; P<0.0001). This inverse relationship was independent of physician specialty and of hospital volume, was consistent across ICD subtypes, and was also evident for in-hospital mortality. Conclusion-Physicians who implant more ICDs have lower rates of procedural complications and in-hospital mortality, independent of hospital procedure volume, physician specialty, and ICD type. (Circulation. 2012;125:57-64.)
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [1] The Relation Between Hospital Procedure Volume and Complications of Cardioverter-Defibrillator Implantation From the Implantable Cardioverter-Defibrillator Registry
    Freeman, James V.
    Wang, Yongfei
    Curtis, Jeptha P.
    Heidenreich, Paul A.
    Hlatky, Mark A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (14) : 1133 - 1139
  • [2] THE RELATION BETWEEN HOSPITAL PROCEDURE VOLUME AND COMPLICATIONS OF CARDIOVERTER-DEFIBRILLATOR IMPLANTATION FROM THE NATIONAL CARDIOVASCULAR DATA REGISTRY
    Freeman, James V.
    Wang, Yongfei
    Curtis, Jeptha
    Heidenreich, Paul A.
    Hlatky, Mark
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] PERIOPERATIVE COMPLICATIONS OF CARDIOVERTER-DEFIBRILLATOR IMPLANTATION - THE EMORY EXPERIENCE
    ZAIM, S
    CONNOLLY, M
    ROMANGONZALEZ, J
    WALTER, P
    CRAVER, J
    JONES, E
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1994, 307 (03): : 185 - 189
  • [4] Psychiatric complications following cardioverter-defibrillator (ICD) implantation
    Kornischka, J
    Schneider, F
    PSYCHIATRISCHE PRAXIS, 2000, 27 (06) : 301 - 303
  • [5] Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation
    Haines, David E.
    Wang, Yongfei
    Curtis, Jeptha
    CIRCULATION, 2011, 123 (19) : 2069 - 2076
  • [6] NONTHORACOTOMY CARDIOVERTER-DEFIBRILLATOR IMPLANTATION BY ELECTROPHYSIOLOGISTS
    MOLINA, JE
    CIRCULATION, 1995, 91 (01) : 252 - 253
  • [7] COMPLICATIONS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    PLATIA, EV
    GRIFFITH, LSC
    REID, PR
    GUARNIERI, T
    WATKINS, L
    MOWER, MM
    MIROWSKI, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A200 - A200
  • [8] Complications associated with pectoral cardioverter-defibrillator implantation: Comparison of subcutaneous and submuscular approaches
    Gold, MR
    Peters, RW
    Johnson, JW
    Shorofsky, SR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) : 1278 - 1282
  • [9] Subserratus implantation of the subcutaneous implantable cardioverter-defibrillator
    Smietana, Jeffrey
    Frankel, David S.
    Serletti, Joseph M.
    Arkles, Jeffrey
    Pothineni, Naga Venkata K.
    Marchlinski, Francis E.
    Schaller, Robert D.
    HEART RHYTHM, 2021, 18 (10) : 1799 - 1804
  • [10] OPERATIVE MORTALITY WITH IMPLANTATION OF THE AUTOMATIC CARDIOVERTER-DEFIBRILLATOR
    MOSTELLER, RD
    LEHMANN, MH
    THOMAS, AC
    JACKSON, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (13): : 1340 - 1345