Anatomical and radiological study applied to distal radius surgery

被引:24
|
作者
Gasse, N. [1 ]
Lepage, D. [1 ]
Pem, R. [2 ]
Bernard, C. [3 ]
Lerais, J. M. [3 ]
Garbuio, P. [1 ]
Obert, L. [1 ]
机构
[1] Univ Hosp Jean Minjoz, Orthoped Traumatol Plast Reconstruct & Hand Surg, Res Unit, INSERM,EA 4268 I4S IFR 133, F-25000 Besancon, France
[2] Pontarlier Hosp Ctr, Surg Unit, F-25304 Pontarlier, France
[3] Univ Hosp, Radiol A&C Federation, F-25000 Besancon, France
关键词
Distal radius; Volar plate; Anatomy; Dorsal tubercle; Wrist arthroplasty; Fracture; VOLAR PLATE OSTEOSYNTHESIS; INTERNAL-FIXATION; RHEUMATOID WRIST; FRACTURES; RUPTURE; COMPLICATIONS; ARTHROPLASTY; MANAGEMENT; SYSTEM; SCREW;
D O I
10.1007/s00276-010-0754-x
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The purpose of this study was to determine, during anterior plating of the distal radius, the length of a screw above which there is a risk for the extensor tendons and the optimal shape of an anterior plate. It was also to determine the projection of the axis of the distal third of the radius on the distal articular surface in case of wrist arthroplasty in order to simplify the procedure. We studied 74 dry radii from adult cadavers. Each one underwent a CT scan. We measured the thickness of each radius at the dorsal tubercle level, at the second compartment level and at the third compartment level. We calculated the metaphyseal-epiphyseal angles of the lateral column and of the intermediate column (Rikli and Regazzoni in J Bone Joint Surg (Br) 78(4):588-592, 1996). We also calculated the projection of the longitudinal axis of the most distal 7 cm of the radius on the distal carpal surface of the radius. Mean thickness at the dorsal tubercle level was 22.1 mm (18-26.1). The mean slope of the lateral column was 155A degrees (143-167) while that of the intermediate column was 145A degrees (134-153). We have found a statistically significant difference (p < 0.0001) between these two slopes. The axis of the distal radius was projected on the posterior-lateral quadrant of the distal articular surface. The emergence of new implants needs a precise evaluation of a fractured, an arthritic or a reconstructed distal radius. The double slope of the distal radius complicates the manufacturing of an "anatomical" plate. The optimal shape is between these two slopes. Moreover, ancillaries for wrist replacement are still approximations, which means that it is important to know the projection of the radial axis on the articular surface of the distal radius.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [21] Bicipital tuberosity bone characteristics in surgical reattachment of the distal biceps: anatomical and radiological study
    Alexandre Lázaro-Amorós
    Xavier Tomás-Batlle
    José Ballesteros-Betancourt
    José Ríos Guillermo
    Xavier Gómez-Bonsfills
    Xavier Cardona-Morera de la Vall
    Manuel Llusà-Pérez
    Surgical and Radiologic Anatomy, 2017, 39 : 135 - 140
  • [22] Bicipital tuberosity bone characteristics in surgical reattachment of the distal biceps: anatomical and radiological study
    Lazaro-Amoros, Alexandre
    Tomas-Batlle, Xavier
    Ballesteros-Betancourt, Jose
    Rios Guillermo, Jose
    Gomez-Bonsfills, Xavier
    Cardona-Morera de la Vall, Xavier
    Llusa-Perez, Manuel
    SURGICAL AND RADIOLOGIC ANATOMY, 2017, 39 (02) : 135 - 140
  • [23] Anatomical fit of seven different palmar distal radius plates
    Johannes Oppermann
    Max Wacker
    Gregor Stein
    Hans-Philipp Springorum
    Wolfram Friedrich Neiss
    Klaus J. Burkhart
    Peer Eysel
    Jens Dargel
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1483 - 1489
  • [24] Anatomical reduction of intra-articular fractures of the distal radius
    Hems, TEJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03): : 460 - 460
  • [25] Anatomical fit of seven different palmar distal radius plates
    Oppermann, Johannes
    Wacker, Max
    Stein, Gregor
    Springorum, Hans-Philipp
    Neiss, Wolfram Friedrich
    Burkhart, Klaus J.
    Eysel, Peer
    Dargel, Jens
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (10) : 1483 - 1489
  • [26] Do Radiological Measurements Correspond to Functional Outcome in Fractures of Distal Radius?- A Cross Sectional Study
    Abrahams, Charles
    Philip, Nithin Thomas
    John, Grace Mary
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (50): : 3769 - 3771
  • [27] Distal Radius Fractures - Assessing Time to Surgery
    Taiwo, B.
    Menyah, E.
    Garcia, S.
    BRITISH JOURNAL OF SURGERY, 2023, 110
  • [28] Corrective surgery after fractures of the distal radius
    Prommersberger, K.-J.
    van Schoonhoven, J.
    UNFALLCHIRURG, 2007, 110 (07): : 617 - 627
  • [29] ANATOMICAL AND FUNCTIONAL EVALUATION OF DISTAL END RADIUS FRACTURES MANAGED BY VOLAR PLATING: A PROSPECTIVE STUDY
    Gyaneshwar, Tank
    Kumar, Gupta Amit
    Parvez, Ahmed
    Gajraj, Singh
    Shantanu, Jaiswal
    Kumar, Anish
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2013, 2 (07): : 802 - 811
  • [30] LOCAL TOPOLOGICAL ANALYSIS APPLIED TO HR-PQCT IMAGES OF THE DISTAL RADIUS AND THE DISTAL TIBIA IN THE OFELY STUDY
    Pialat, Jean-Baptiste
    Boutroy, Stephanie
    Gouttenoire, Pierre-Jean
    Ellouz, Rafaa
    Vilayphiou, Nicolas
    Sornay-Rendu, Elisabeth
    Chapurlat, Roland
    Peyrin, Francoise
    OSTEOPOROSIS INTERNATIONAL, 2013, 24 : S233 - S234