A design of real-time unipath polarization imaging system based on Wollaston prism

被引:4
|
作者
Xu Jie [1 ]
Liu Fei [1 ]
Liu Jie-Tao [1 ]
Wang Jiao-Yang [1 ]
Han Ping-Li [1 ]
Zhou Cong-Hao [2 ]
Shao Xiao-Peng [1 ]
机构
[1] Xidian Univ, Sch Phys & Optoelect Engn, Xian 710071, Peoples R China
[2] Northeastern Univ, Sch Sci & Technol, Shenyang 110004, Peoples R China
基金
中国国家自然科学基金;
关键词
polarization imaging; Wollaston prism; telescopic lens in image space; single CCD chip;
D O I
10.7498/aps.65.134201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A real-time polarization imaging system employing the Wollaston prism and a single charge-coupled device (CCD) chip covering a wavelength range of 400-650 nm is proposed to avoid the false polarization information from dynamic scenes in non-real-time polarization detection imaging method. An architecture consisting of telescope lens, collimation lens, Wollaston prism, the imaging lens and a single CCD chip is employed in the system. The telescope lens is used to focus the incoming light on an intermediate image. And after collimation, the beam is angularly separated by the Wollaston prism. Two beams corresponding to ordinary light and extraordinary light are subsequently focused on the CCD plane via the imaging lens. The telescope lens is designed to have a telecentric structure in the imaging space, and the invert of which is used as the collimation lens, the completely symmetrical structure design is used to reduce the influence of aberrations. More abundant details from this system can be obtained by using matched image post-processing strategy, which is beneficial to high-quality target detection with enhanced working distance and improved environment adaptability. After joint-designing and optimization, the system modulation transfer function value at cutoff frequency is higher than 0.55, and the root-mean-square radius of the system is less than 5.3 mu m, which is smaller than the pixel size of the CCD detector. Additionally, the lateral chromatic aberration of the system is much smaller than the diameter of airy disk, and the absolute values of all kinds of aberrations are kept smaller than 0.02 at the same time. The calculation results show that all the aberrations are mostly corrected. The system imaging is numerically modeled and analyzed, and it is demonstrated that two intensity images with perpendicular polarization states appear adjacently on the CCD plane simultaneously in the imaging simulation. One image is formed with the fraction of the backscattered light polarized parallelly to the incident light, and the other with light polarized orthogonally to the incidence, indicating that the expected design is accomplished. Compared with the traditional amplitude-split polarization imaging system, the proposed real-time polarization imaging system shows that the improved performance for real-time detection with promoted power efficiency, spatial resolution, and the light crosstalk in focal plane is well handled. Moreover, the joint design of the whole system can compensate for the distortion aberration in the vertical direction of the CCD detector, which means that a further improvement of image quality can be expected. The proposed system has a promising perspective in the fields of underwater imaging detection, astronomical observation, remote sensing, biological tissues inspection, and environmental monitoring.
引用
收藏
页数:9
相关论文
共 20 条
  • [11] Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography
    Makita, S
    Yasuno, Y
    Endo, T
    Itoh, M
    Yatagai, T
    [J]. APPLIED OPTICS, 2006, 45 (06) : 1142 - 1147
  • [12] High-speed imaging chopper polarimetry
    Matchko, Roy M.
    Gerhart, Grant R.
    [J]. OPTICAL ENGINEERING, 2008, 47 (01)
  • [13] The polarization-difference interference imaging spectrometer-I. concept, principle, and operation
    Mu Ting-Kui
    Zhang Chun-Min
    Li Qi-Wei
    Wei Yu-Tong
    Chen Qing-Ying
    Jia Chen-Ling
    [J]. ACTA PHYSICA SINICA, 2014, 63 (11)
  • [14] Third-order aberrations of a plane symmetric optical system
    Sun Jin-Xia
    Pan Guo-Qing
    Liu Ying
    [J]. ACTA PHYSICA SINICA, 2013, 62 (09)
  • [15] Polarization phase stepping with a Savart element
    Weijers, AL
    van Brug, H
    Frankena, HJ
    [J]. APPLIED OPTICS, 1998, 37 (22) : 5150 - 5155
  • [16] Wu Z Y, 2011, ACTA OPT SINICA, V31
  • [17] YUAN YL, 2014, ACTA OPT SINICA, V34, P23001
  • [18] Linear polarization difference imaging and its potential applications
    Zeng Nan
    Jiang Xiaoyu
    Gao Qiang
    He Yonghong
    Ma Hui
    [J]. APPLIED OPTICS, 2009, 48 (35) : 6734 - 6739
  • [19] [赵劲松 Zhao Jinsong], 2013, [红外技术, Infrared Technology], V35, P743
  • [20] Zhu Huafeng, 2012, ACTA OPT SINICA, V32