Decremental pulmonary venous pulse propagation:: Impact for catheter ablation in focal atrial fibrillation

被引:1
|
作者
Lewalter, T [1 ]
Burkhardt, D [1 ]
Bielik, H [1 ]
Schrickel, J [1 ]
Bitzen, A [1 ]
Shlevkov, N [1 ]
Yang, A [1 ]
Lüdertiz, B [1 ]
Schwab, JO [1 ]
机构
[1] Univ Bonn, Dept Med Cardiol, D-53105 Bonn, Germany
关键词
arrhythmia; atrial fibrillation; catheter ablation; mapping; pulmonary vein;
D O I
10.1023/A:1026248827908
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electrical isolation of pulmonary veins (PV's) is crucial to achieve success in catheter ablation for trigger elimination in focal atrial fibrillation (AF). To guide ostial PV radiofrequency (RF) delivery, it is necessary to identify the electrical breakthrough (EBT) between PV and left atrium. For this purpose, coronary sinus (CS) fixed rate pacing is commonly used. This study evaluated, whether CS extrastimulus pacing is superior in identifying the EBT area as compared to fixed rate pacing. Methods: In 9 patients (51 +/- 10 years) undergoing a left sided electrophysiological study for AF ablation, 25 PV's (10 right and 15 left-sided PV's) were mapped using a 4 French fixed-wire catheter with eight 6 mm coiled Platinum electrodes in a distal looped configuration (Revelation Helix, Cardima Inc.). For mapping and ablation the electrode loop was positioned in the PV ostium rectangular to the longitudinal PV axis. EBT area was identified as those electrodes indicating the earliest PV signals during CS pacing. We measured number of EBT electrodes and time between EBT and the latest activated bipoles at the electrode loop during fixed rate and extrastimulus pacing. The reduction of two or more EBT electrodes was defined as a significant benefit in EBT identification. Results: In 22 of 25 PV's mapped PV potentials could be observed. Performing fixed rate pacing the EBT area was identified in a mean of 4.2 +/- 1 electrodes, whereas using extrastimulus pacing, EBT area could be significantly reduced to 2.3 +/- 0.8 electrodes. The time between EBT and latest electrode activated increased from 14 +/- 7 ms to 22 +/- 10 ms indicating an intrapulmonary conduction delay during extrastimulus pacing. In 13 of 22 PV's mapped (59%), extrastimulus pacing was beneficial in the identification of the EBT, as the primary target for RF delivery. Conclusions: CS extrastimulus pacing induces intra-PV decremental conduction properties allowing one to identify a more localised and smaller EBT area as the primary target for RF delivery. Performing PV ablation to treat focal AF, extrastimulus maneouvers allow to unmask the "true" EBT and thus may help to limit intrapulmonary RF delivery.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [41] THE IMPACT OF CATHETER ABLATION ON DIALYSIS PATIENTS WITH ATRIAL FIBRILLATION
    Shibata, Kazuhiko
    Sohara, Hiroshi
    Kuji, Tadashi
    Kawata, Seiichi
    Kogudhi, Naoaki
    Nishihara, Masahiro
    Satta, Hidehisa
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 448 - 448
  • [42] THE IMPACT OF CATHETER ABLATION ON HEMODIALYSIS PATIENTS WITH ATRIAL FIBRILLATION
    Shibata, Kazuhiko
    Sohara, Hiroshi
    Kuji, Tadashi
    Satta, Hidehisa
    Kawata, Seiichi
    Kaneda, Tomoko
    Koguchi, Naoaki
    Nishihara, Masahiro
    Yasuda, Gen
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 76 - 76
  • [43] Impact of pulmonary artery pressure on recurrence after catheter ablation in patients with atrial fibrillation
    Choi, Yun Young
    Choi, Jong-Il
    Jeong, Joo Hee
    Lee, Hyoung Seok
    Kim, Yun Gi
    Kim, Mi-Na
    Roh, Seung-Young
    Shim, Jaemin
    Kim, Jin Seok
    Park, Seong-Mi
    Kim, Young-Hoon
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [44] Impact of Catheter Ablation of Atrial Fibrillation on Disease Progression
    Benali, Karim
    Macle, Laurent
    Haissaguerre, Michel
    Nattel, Stanley
    Deyell, Marc
    Da Costa, Antoine
    Andrade, Jason G.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2025, 11 (02) : 421 - 435
  • [45] Impact of Catheter Ablation for Atrial Fibrillation on Quality of Life
    Rohrer, Ursula
    Manninger, Martin
    Zirlik, Andreas
    Scherr, Daniel
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [46] Case Report: Circumferential Pulmonary Vein Mapping and Ablation in Focal Atrial Fibrillation: Single Catheter Technique
    Thorsten Lewalter
    Dietmar Burkhardt
    Helga Bielik
    Jan Schrickel
    Alexander Yang
    Nikolai Shlevkov
    Rainer Schimpf
    Jörg O. Schwab
    Berndt Lüderitz
    Journal of Interventional Cardiac Electrophysiology, 2002, 7 : 165 - 170
  • [47] Catheter ablation of focal atrial fibrillation: First experience with ultrasound energy for selective pulmonary vein isolation
    Ernst, SIS
    Loeber, F
    Cappato, R
    Ouyang, FF
    Volkmer, M
    Goya, M
    Vogtmann, T
    Kuck, KH
    CIRCULATION, 2000, 102 (18) : 484 - 485
  • [48] Pulmonary vein stenosis following catheter ablation of atrial fibrillation
    Pürerfellner, H
    Martinek, M
    CURRENT OPINION IN CARDIOLOGY, 2005, 20 (06) : 484 - 490
  • [49] Pulmonary vein stenosis after catheter ablation of atrial fibrillation
    Robbins, IM
    Colvin, EV
    Doyle, TP
    Kemp, WE
    Loyd, JE
    McMahon, WS
    Kay, GN
    CIRCULATION, 1998, 98 (17) : 1769 - 1775
  • [50] Pulmonary vein stenosis after catheter ablation for atrial fibrillation
    Pappone, C
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (02) : 165 - 167