Decremental pulmonary venous pulse propagation:: Impact for catheter ablation in focal atrial fibrillation

被引:1
|
作者
Lewalter, T [1 ]
Burkhardt, D [1 ]
Bielik, H [1 ]
Schrickel, J [1 ]
Bitzen, A [1 ]
Shlevkov, N [1 ]
Yang, A [1 ]
Lüdertiz, B [1 ]
Schwab, JO [1 ]
机构
[1] Univ Bonn, Dept Med Cardiol, D-53105 Bonn, Germany
关键词
arrhythmia; atrial fibrillation; catheter ablation; mapping; pulmonary vein;
D O I
10.1023/A:1026248827908
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electrical isolation of pulmonary veins (PV's) is crucial to achieve success in catheter ablation for trigger elimination in focal atrial fibrillation (AF). To guide ostial PV radiofrequency (RF) delivery, it is necessary to identify the electrical breakthrough (EBT) between PV and left atrium. For this purpose, coronary sinus (CS) fixed rate pacing is commonly used. This study evaluated, whether CS extrastimulus pacing is superior in identifying the EBT area as compared to fixed rate pacing. Methods: In 9 patients (51 +/- 10 years) undergoing a left sided electrophysiological study for AF ablation, 25 PV's (10 right and 15 left-sided PV's) were mapped using a 4 French fixed-wire catheter with eight 6 mm coiled Platinum electrodes in a distal looped configuration (Revelation Helix, Cardima Inc.). For mapping and ablation the electrode loop was positioned in the PV ostium rectangular to the longitudinal PV axis. EBT area was identified as those electrodes indicating the earliest PV signals during CS pacing. We measured number of EBT electrodes and time between EBT and the latest activated bipoles at the electrode loop during fixed rate and extrastimulus pacing. The reduction of two or more EBT electrodes was defined as a significant benefit in EBT identification. Results: In 22 of 25 PV's mapped PV potentials could be observed. Performing fixed rate pacing the EBT area was identified in a mean of 4.2 +/- 1 electrodes, whereas using extrastimulus pacing, EBT area could be significantly reduced to 2.3 +/- 0.8 electrodes. The time between EBT and latest electrode activated increased from 14 +/- 7 ms to 22 +/- 10 ms indicating an intrapulmonary conduction delay during extrastimulus pacing. In 13 of 22 PV's mapped (59%), extrastimulus pacing was beneficial in the identification of the EBT, as the primary target for RF delivery. Conclusions: CS extrastimulus pacing induces intra-PV decremental conduction properties allowing one to identify a more localised and smaller EBT area as the primary target for RF delivery. Performing PV ablation to treat focal AF, extrastimulus maneouvers allow to unmask the "true" EBT and thus may help to limit intrapulmonary RF delivery.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [1] Decremental Pulmonary Venous Pulse Propagation: Impact for Catheter Ablation in Focal Atrial Fibrillation
    Thorsten Lewalter
    Dietmar Burkhardt
    Helga Bielik
    Jan Schrickel
    Alexander Bitzen
    Nikolai Shlevkov
    Alexander Yang
    Berndt Lüderitz
    Jörg O. Schwab
    Journal of Interventional Cardiac Electrophysiology, 2003, 9 : 269 - 273
  • [2] Decremental intravenous pulse propagation during extrastimulus pacing:: relevance for catheter ablation of focal atrial fibrillation
    Lewalter, T
    Burkhardt, D
    Chun, S
    Schimpf, R
    Bielik, H
    Schrickel, J
    Shlevkov, N
    Yang, A
    Lüderitz, B
    EUROPACE, 2002, 4 (04): : 411 - 415
  • [3] Clinical impact of radiofrequency catheter ablation in focal atrial fibrillation
    Castellano, NP
    Villacastin, J
    Moreno, J
    Torrent, MJG
    Moreno, MC
    Morales, R
    Alvarez, L
    Macaya, C
    EUROPEAN HEART JOURNAL, 2003, 24 : 392 - 392
  • [4] Pulmonary vein stenosis complicating catheter ablation of focal atrial fibrillation
    Scanavacca, MI
    Kajita, LJ
    Vieira, M
    Sosa, EA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (06) : 677 - 681
  • [5] Intravascular pulmonary venous ultrasound imaging for catheter ablation of atrial fibrillation
    Cismaru, Gabriel
    Schiau, Serban
    Muresan, Lucian
    Rosu, Radu
    Puiu, Mihai
    Gusetu, Gabriel
    Pop, Dana
    Zdrenghea, Dumitru
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (04) : 309 - 314
  • [6] Radiofrequency catheter ablation of focal atrial fibrillation
    Peinado, RP
    Llorens, JLM
    Guindal, JAG
    Daza, JAS
    REVISTA ESPANOLA DE CARDIOLOGIA, 1998, 51 (06): : 494 - 497
  • [7] Mew technique for simultaneous catheter mapping of pulmonary veins for catheter ablation in focal atrial fibrillation
    Kumagai, K
    Gondo, N
    Matsumoto, N
    Noguchi, H
    Tojo, H
    Yasuda, T
    Nakashima, H
    Saku, K
    CARDIOLOGY, 2000, 94 (04) : 233 - 238
  • [8] Catheter ablation in a patient with partial anomalous pulmonary venous return and atrial fibrillation
    Fukamizu, Seiji
    Sakurada, Harumizu
    Nishizaki, Mitsuhiro
    Hiraoka, Masayasu
    HEART RHYTHM, 2012, 9 (06) : 1002 - 1003
  • [9] Efficacy of combined treatment with focal ablation and pulmonary venous isolation for atrial fibrillation
    Kumagai, K
    Matsumoto, N
    Noguchi, H
    Tojo, H
    Yasuda, T
    Saku, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 119A - 120A
  • [10] Percutaneous catheter ablation of atrial fibrillation in a patient with an anomalous pulmonary venous connection
    De Greef, Yves
    Vandekerckhove, Yves
    Tavernier, Rene
    Dossche, Karl
    Duytschaever, Mattias
    EUROPACE, 2009, 11 (02): : 263 - 264