Development of an efficient extraction method for oxytetracycline in animal manure for high performance liquid chromatography analysis

被引:1
|
作者
Yuan, Shoujun [1 ]
Wang, Qiquan [1 ]
Yates, Scott R. [2 ]
Peterson, Nyles G. [3 ]
机构
[1] Delaware State Univ, Dept Chem, Dover, DE 19901 USA
[2] ARS, USDA, US Salin Lab, Riverside, CA USA
[3] Univ Calif Cooperat Extens, San Bernardino, CA 92407 USA
基金
美国国家科学基金会;
关键词
Oxytetracycline; tetracyclines; antibiotic; extraction; manure; analysis; high performance liquid chromatography; SOLID-PHASE EXTRACTION; TETRACYCLINE RESIDUES; RESISTANCE GENES; ANTIBIOTICS; CHLORTETRACYCLINE; SOILS; WATER; DEGRADATION; VALIDATION; CLEANUP;
D O I
10.1080/03601234.2010.502404
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Oxytetracycline (2-(amino-hydroxy-methylidene)-4-dimethylamino-5,6,10,11,12a-pentahydroxy-6-methyl-4,4a, 5,5a-tetrahydrotetracene-1,3,12-trione) is a major member of the tetracycline antibiotics family of which are widely administered to animals in concentrated animal feeding operations for purposes of therapeutical treatment and health protection. With the disposal of animal manure as fertilizer into agricultural land, tetracyclines enter the environment. However, tetracyclines chelate with multivalent cations and proteins, resulting in low extraction efficiencies from animal manure for tetracycline residue analysis. In this study an efficient extraction method for oxytetracycline from steer manure using methanol/water solution amended with chelating organic acid was developed for the analysis of high performance liquid chromatography. The effect of species and amount of amendment acids, shaking time, methanol/water ratio, manure weight, and repeated times of extraction was investigated. It was optimized to amend 2.5 g citric acid and 1.1 g oxalic acid with 10.0 g manure sample in a 50-ml centrifuge tube and extract with 15 ml methanol/water (9: 1 in volume) by vigorously shaking for 30 min in a reciprocating shaker. After centrifugation at 11,000 rpm, supernatant is collected. Sample was extracted for a total of 3 times. The developed extraction method was further applied to extract oxytetracycline from fresh and aged cow manure, swine and poultry manure, and soil. Satisfactory recoveries ranging from (84.1 +/- 2.4) % to (102.0 +/- 3.1) % were obtained, demonstrating that the optimized extraction method is robust for oxytetracycline from different manure sample matrixes.
引用
收藏
页码:612 / 620
页数:9
相关论文
共 50 条
  • [31] HIGH - PERFORMANCE LIQUID CHROMATOGRAPHY METHOD VALIDATION AND DEVELOPMENT STRATEGY FOR RIFABUTIN
    Singh, Gyanendra
    Srivastava, A. K.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2018, 9 (09): : 3903 - 3907
  • [32] Development and validation of a method for determination of sertralin by high performance liquid chromatography
    Zamoum, R.
    Azzouz, M.
    Abtroun, R.
    Reggabi, M.
    Alamir, B.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2014, 28 : 111 - 111
  • [33] Residue analysis of oxytetracycline in water and sediment samples by high-performance liquid chromatography and immunochemical techniques
    Himmelsbach, M
    Buchberger, W
    MICROCHIMICA ACTA, 2005, 151 (1-2) : 67 - 72
  • [34] A highly efficient method for derivatization of fatty acids for high performance liquid chromatography
    Czauderna, M
    Kowalczyk, J
    Niedzwiedzka, KM
    Wasowska, I
    JOURNAL OF ANIMAL AND FEED SCIENCES, 2002, 11 (03): : 517 - 526
  • [35] Development of high-performance liquid chromatography for the determination of carbadox and olaquindox in animal feed
    Kesiunaite, Giedre
    Padarauskas, Audrius
    CHEMIJA, 2007, 18 (03): : 30 - 34
  • [36] Development and validation of an improved liquid chromatographic method for the analysis of oxytetracycline
    Diana, J
    Ping, G
    Roets, E
    Hoogmartens, J
    CHROMATOGRAPHIA, 2002, 56 (5-6) : 313 - 318
  • [37] Development and validation of an improved liquid chromatographic method for the analysis of oxytetracycline
    J. Diana
    G. Ping
    E. Roets
    J. Hoogmartens
    Chromatographia, 2002, 56 : 313 - 318
  • [38] ULTRASONIC EXTRACTION COUPLED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR PARABENS ANALYSIS IN COSMETICS
    Liu, Z. M.
    Xu, F. H.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 119 : 52 - 52
  • [39] Efficient Method for Extraction and Simultaneous Determination of Active Constituents in Cornus officinalis by Reflux Extraction and High Performance Liquid Chromatography with Diode Array Detection
    Kim, Seung Hyun
    Lee, Mi Kyeong
    Ahn, Mi-Jeong
    Lee, Ki Yong
    Kim, Young Choong
    Sung, Sang Hyun
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (06) : 822 - 832
  • [40] Development of coupled supercritical fluid extraction-high performance liquid chromatography for quinone analysis in activated sludge
    Juliasih, Ni Luh Gede Ratna
    Yuan, Lee Chang
    Atsuta, Yoichi
    Daimon, Hiroyuki
    SEPARATION SCIENCE AND TECHNOLOGY, 2016, 51 (03) : 439 - 446