Active control of axial-flow fan noise using magnetic bearings

被引:3
|
作者
Piper, GE [1 ]
Watkins, JM
Thorp, OG
机构
[1] USN Acad, Annapolis, MD 21146 USA
[2] Wichita State Univ, Wichita, KS 67260 USA
关键词
noise control actuator; active magnetic bearings; active noise control; fan noise;
D O I
10.1177/1077546305057261
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper we present a novel approach to reducing blade-rate noise of axial-flow fans. By using magnetic bearings as a noise control actuator, it is possible to collocate the anti-noise source with the disturbance noise source. This approach allows for global noise reduction throughout the sound field. A DC motor connected to a fan by a short rigid shaft was used to demonstrate this approach. The shaft was supported in the radial and axial directions by magnetic bearings. The bearings provide position control of the shaft and fan; this position control can be used to vibrate the fan at a desired frequency and amplitude. Controlled vibration of the fan allows its use as a speaker in an active noise control scheme. Noise control was implemented on a dedicated digital signal processor using a least mean square algorithm. The output of the noise control algorithm supplies the position commands for the magnetic bearing controller. Experimental data showed that by actuating the axial thrust bearing, the noise output of a fan could be reduced by 4 dB at the error microphone, and 3 dB at points away from the error microphone.
引用
收藏
页码:1221 / 1232
页数:12
相关论文
共 50 条
  • [31] ROTOR WAKE CHARACTERISTICS OF A TRANSONIC AXIAL-FLOW FAN
    HATHAWAY, MD
    GERTZ, JB
    EPSTEIN, AH
    STRAZISAR, AJ
    [J]. AIAA JOURNAL, 1986, 24 (11) : 1802 - 1810
  • [32] Application of casing treatment to an industrial axial-flow fan
    Hill, S.D.
    Elder, R.L.
    McKenzie, A.B.
    [J]. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 1998, 212 (4 A4): : 225 - 233
  • [33] Efficiency of an Axial-Flow Fan with Twisted Blades.
    Parafiniuk, Jan
    [J]. 1600, (35):
  • [34] Application of casing treatment to an industrial axial-flow fan
    Hill, SD
    Elder, RL
    McKenzie, AB
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1998, 212 (A4) : 225 - 233
  • [35] An integrated performance analysis for a small axial-flow fan
    Lin, S-C
    Tsai, M-L
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2010, 224 (C9) : 1981 - 1994
  • [36] Effect of meridional shape on performance of axial-flow fan
    Xin Chen
    Linlin Cao
    Peng Yan
    Peng Wu
    Dazhuan Wu
    [J]. Journal of Mechanical Science and Technology, 2017, 31 : 5141 - 5151
  • [37] Effect of meridional shape on performance of axial-flow fan
    Chen, Xin
    Cao, Linlin
    Yan, Peng
    Wu, Peng
    Wu, Dazhuan
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (11) : 5141 - 5151
  • [38] A PREDICTION MODEL FOR THE VORTEX SHEDDING NOISE FROM THE WAKE OF AN AIRFOIL OR AXIAL-FLOW FAN BLADES
    LEE, C
    CHUNG, MK
    KIM, YH
    [J]. JOURNAL OF SOUND AND VIBRATION, 1993, 164 (02) : 327 - 336
  • [39] CONTROL OF THE NOISE FROM AXIAL-FLOW FANS BY MEANS OF BLADE MODULATION
    ROGER, M
    [J]. ACUSTICA, 1994, 80 (03): : 247 - 259
  • [40] Vibration and noise of an axial flow fan
    Kalmár-Nagy, Tamás
    Bak, Bendegúz Dezso
    Benedek, Tamás
    Vad, János
    [J]. Periodica Polytechnica Mechanical Engineering, 2015, 59 (03): : 109 - 113