Measuring fecal steroids - Guidelines for practical application

被引:384
|
作者
Palme, R [1 ]
机构
[1] Univ Vet Med, Dept Nat Sci, Inst Biochem, A-1210 Vienna, Austria
来源
BIRD HORMONES AND BIRD MIGRATIONS: ANALYZING HORMONES IN DROPPINGS AND EGG YOLKS AND ASSESSING ADAPTATIONS IN LONG-DISTANCE MIGRATION | 2005年 / 1046卷
关键词
steroid hormones; estrogens; gestagens; androgens; glucocorticoids; noninvasive monitoring; feces/faeces; validation; sex differences; stress;
D O I
10.1196/annals.1343.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
During the past 20 years, measuring steroid hormone metabolites in fecal samples has become a widely appreciated technique, because it has proved to be a powerful, noninvasive tool that provides important information about an animal's endocrine status (adrenocortical activity and reproductive status). However, although sampling is relatively easy to perform and free of feedback, a careful consideration of various factors is necessary to achieve proper results that lead to sound conclusions. This article aims to provide guidelines for an adequate application of these techniques. It is meant as a checklist that addresses the main topics of concern, such as sample collection and storage, time delay extraction procedures, assay selection and validation, biological relevance, and some confounding factors. These issues are discussed briefly here and in more detail in other recent articles.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [21] PRACTICAL GUIDELINES
    TOOZE, J
    TRENDS IN BIOCHEMICAL SCIENCES, 1976, 1 (11) : N246 - N247
  • [22] Guidelines for Guidelines: Measuring Trustworthiness
    Ransohoff, David F.
    Sox, Harold C.
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (20) : 2530 - 2531
  • [23] Development of the heliborne separation measuring system and its practical application
    Motomura, T
    Hirao, M
    Nakamura, K
    Kikuchi, T
    ESMO '98 PROCEEDINGS: ESMO '98 - 1998 IEEE 8TH INTERNATIONAL CONFERENCE ON TRANSMISSION & DISTRIBUTION CONSTRUCTION, OPERATION & LIVE-LINE MAINTENANCE PROCEEDINGS, 1996, : 203 - 209
  • [24] Practical application of the DVO guidelines. In an osteological specialist's practice
    Foertsch, M.
    Schmidt, T.
    Feldmann, C.
    Maurer, T.
    TRAUMA UND BERUFSKRANKHEIT, 2014, 16 (02) : 110 - 121
  • [25] BUMPED TAPE AUTOMATED BONDING (BTAB) PRACTICAL APPLICATION GUIDELINES.
    Kanz, J.W.
    Braun, G.W.
    Unger, R.F.
    Proceedings - Electronic Components and Technology Conference, 1979, : 319 - 330
  • [27] FECAL STEROIDS AND CLOSTRIDIA IN PATIENTS WITH FAMILIAL POLYPOSIS
    DRASAR, BS
    FERNANDEZ, F
    HEATON, S
    HILL, MJ
    JOURNAL OF MEDICAL MICROBIOLOGY, 1975, 8 (02) : PR8 - PR8
  • [28] EFFECT OF DIET ON BLOOD AND FECAL STEROIDS IN THE RAT
    KIM, KS
    IVY, AC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1951, 167 (03): : 802 - 802
  • [29] FECAL NEUTRAL STEROIDS OF HUMANS ON CONTROLLED DIETS
    ROGERS, IT
    GERHARDT, K
    GEHRKE, CW
    FLYNN, MA
    MAIER, BR
    TSUTAKAWA, R
    HENTGES, DJ
    FEDERATION PROCEEDINGS, 1976, 35 (03) : 418 - 418
  • [30] FECAL STEROIDS IN POLYPOSIS COLI AND ILEORECTOSTOMY PATIENTS
    WATNE, AL
    CORE, SK
    JOURNAL OF SURGICAL RESEARCH, 1975, 19 (03) : 157 - 161