Donor-site morbidity following breast reconstruction with a latissimus dorsi flap - A prospective study

被引:1
|
作者
Hojvig, Jens H. [1 ]
Henriksen, Marius [2 ]
Bartholdy, Cecilie R. [2 ]
Bonde, Christian T. [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Plast Surg & Burns Treatment, Blegdamsvej 60,Afsnit 9441, DK-2100 Copenhagen O, Denmark
[2] Bispebjerg & Frederiksberg Hosp, Parker Inst, Copenhagen, Denmark
关键词
Breast reconstruction; Reconstructive surgery; Flap surgery; LD breast reconstruction; Latissimus dorsi; Plastic surgery; SHOULDER FUNCTION; FUNCTIONAL-EVALUATION; PERSISTENT PAIN; PROSTHESIS; MASTECTOMY; HARVEST;
D O I
10.1016/j.bjps.2022.01.036
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Despite a trend toward the use of perforator-based flaps for autologous breast reconstruction, the m. latissimus dorsi (LD) flap remains a popular alternative. Several studies have sought to uncover the shoulder-related donor-site morbidity, but the results are inconclusive. This study aims at evaluating what impact breast reconstruction with an LD flap has on shoulder strength, range of motion (ROM), lymphedema, sensory disturbances, and patients' ability to perform activities of daily living (ADL). Materials and methods: In a prospective observational study, we examined 20 female patients undergoing delayed breast reconstruction with an LD flap. The primary outcome was a change in shoulder strength, measured with the Biodex System4 Pro-dynamometer. ROM was assessed using two-dimensional photogrammetry. Furthermore, the patients' self-reported pain, lymphedema, sensory disturbances, and ability to perform ADL were assessed using a questionnaire. Measurements were performed pre-operatively at 3 months and 12 months postoperatively. Results: Of the 20 included patients, 17 completed the follow-up. At the 12 months followup, a significant loss of isometric shoulder strength of 17% was observed in shoulder adduction (P <0.001) and 21% in extension (P <0.001). Isometric strength and ability to perform ADL and ROM were unchanged. There was a decrease in the number of patients reporting problems with lymphedema (10 to 7) and an increase in the incidence of sensory disturbances (10 to 13). Conclusion: A loss of shoulder strength was observed following the transfer of the LD flap; however, the procedure did not hinder the post-operative performance of ADLs for the patients. LD reconstruction seems to be a safe procedure. (C) 2022 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd.
引用
收藏
页码:2205 / 2210
页数:6
相关论文
共 50 条
  • [31] A Novel Design of the Multilobed Latissimus Dorsi Myocutaneous Flap to Achieve Primary Donor-Site Closure in the Reconstruction of Large Defects
    Zhang, Yi Xin
    Messmer, Caroline
    Pang, Fong Kuong
    Ong, Yee Siang
    Feng, Shao Qing
    Qian, Yunliang
    Spinelli, Giuseppe
    Agostini, Tommaso
    Levin, L. Scott
    Lazzeri, Davide
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (05) : 752E - 758E
  • [32] Recurrence of breast cancer in the donor site after latissimus dorsi flap
    Hoopmann, M
    Warm, M
    Schöndorf, T
    Possover, M
    Mallmann, PK
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 112 (03) : 819 - 821
  • [33] Comparison of morbidity-related seroma formation following conventional latissimus dorsi flap versus muscle-sparing latissimus dorsi flap breast reconstruction
    Sowa, Yoshihiro
    Numajiri, Toshiaki
    Nakatsukasa, Katsuhiko
    Sakaguchi, Koichi
    Taguchi, Tetsuya
    ANNALS OF SURGICAL TREATMENT AND RESEARCH, 2017, 93 (03) : 119 - 124
  • [34] DONOR-SITE MORBIDITY OF THE GRACILIS FLAP
    DEUTINGER, M
    KUZBARI, R
    PATERNOSTROSLUGA, T
    QUITTAN, M
    ZAUNERDUNGL, A
    WORSEG, A
    TODOROFF, B
    HOLLE, J
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 95 (07) : 1240 - 1244
  • [35] Re: 'Assessment of long-term donor-site morbidity after harvesting the latissimus dorsi flap for neonatal myelomeningocele repair'
    Touil, Leila
    Fisher, David M.
    Fattah, Adel Y.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (05): : 747 - 749
  • [36] Objective Comparison of Donor-Site Morbidity following Full and Thoracodorsal Nerve-Preserving Split Latissimus Dorsi Flaps
    Oberhofer, Haley M.
    Samant, Sonja S.
    Swan, Courtney C.
    Wolfe, Erin M.
    Satteson, Ellen S.
    Leyngold, Mark M.
    Chim, Harvey
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 149 (05) : 966E - 971E
  • [37] A Prospective Assessment of Shoulder Morbidity and Recovery Time Scales following Latissimus Dorsi Breast Reconstruction
    Glassey, Nicole
    Perks, Graeme B.
    McCulley, Stephen J.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (05) : 1334 - 1340
  • [38] Delayed Breast Reconstruction with Latissimus Dorsi Flap
    Agaoglu, Galip
    Erol, O. Onur
    AESTHETIC PLASTIC SURGERY, 2009, 33 (03) : 413 - 420
  • [39] Delayed Breast Reconstruction with Latissimus Dorsi Flap
    Galip Agaoglu
    O. Onur Erol
    Aesthetic Plastic Surgery, 2009, 33 : 413 - 420
  • [40] Breast reconstruction with the autologous latissimus dorsi flap
    Delay, E.
    Florzac, A. S.
    Frobert, P.
    ANNALES DE CHIRURGIE PLASTIQUE ESTHETIQUE, 2018, 63 (5-6): : 422 - 436