Sensitive and Selective Differential Pulse Voltammetry Detection of Cd(II) and Pb(II) Using Nitrogen-Doped Porous Carbon Nanofiber Film Electrode

被引:13
|
作者
Gao, Sanshuang [1 ,2 ]
Xu, Chuyang [1 ]
Yalikun, Nuerbiya [2 ]
Mamat, Xamxikamar [2 ]
Li, Yongtao [2 ]
Wagberg, Thomas [3 ]
Hu, Xun [4 ]
Liu, Jing [5 ]
Luo, Jun [5 ]
Hu, Guangzhi [2 ,3 ]
机构
[1] Anhui Univ Sci & Technol, Sch Mat Sci & Engn, Huainan 232001, Peoples R China
[2] Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Key Lab Chem Plant Resources Arid Reg, State Key Lab Basis Xinjiang Indigenous Med Plant, Urumqi 830011, Peoples R China
[3] Umea Univ, Dept Phys, S-90187 Umea, Sweden
[4] Univ Jinan, Sch Mat Sci & Engn, Jinan 250022, Shandong, Peoples R China
[5] Tianjin Univ Technol, Inst New Energy Mat & Low Carbon Technol, Sch Mat Sci & Engn, Ctr Electron Microscopy, Tianjin 300384, Peoples R China
基金
中国国家自然科学基金; 中国科学院西部之光基金; 瑞典研究理事会;
关键词
SIMULTANEOUS ELECTROCHEMICAL DETECTION; ANODIC-STRIPPING VOLTAMMETRY; OXYGEN REDUCTION REACTION; ETHER-MODIFIED ELECTRODES; SCREEN-PRINTED ELECTRODE; REDUCED GRAPHENE OXIDE; MESOPOROUS CARBON; PASTE ELECTRODE; HEAVY-METALS; LEAD;
D O I
10.1149/2.1611713jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Carbon matrix materials are regarded as one of the most important electrode materials for heavy metal detection. But even so, optimization procedures of carbon nanofibers (CNFs) for tracing Cd(II) and Pb(II) remains challenging. Here, zeolitic imidazolate framework (ZIF-8)/polyacrylonitrile (PAN)-derived nitrogen-doped porous carbon nanofibers (N-PCNFs) were investigated as a new electrode material for determining the concentration of Cd(II) and Pb(II). By optimizing electrochemical conditions such as deposition potential, deposition time, pH of buffer solution, and quantity of N-PCNFs loaded on a glassy carbon electrode (GCE), the linear response curves of Cd(II) and Pb(II) could be obtained. Due to the unique structural feature and N content, the N-PCNFs possess excellent detection limits of 0.8 mu g L-1 for Cd(II) and 0.3 mu g L-1 for Pb(II) (S/N = 3). To manifest the practical use of the sensor platform the concentration of Cd(II) and Pb(II) in normal tap and waste water were monitored. According to the ICP-MS results, the calculated recovery (97.0-107%) indicates that N-PCNFs have potential as a candidate material to monitor the concentration of Cd(II) and Pb(II) in practical samples. (c) 2017 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H967 / H974
页数:8
相关论文
共 50 条
  • [21] Monitoring of Zn(II), Cd(II), Pb(II) and Cu(II) During Refining of Some Vegetable Oils Using Differential Pulse Anodic Stripping Voltammetry
    Kucukkolbasi, Semahat
    Temur, Osman
    Kara, Huseyin
    Khaskheli, Abdul Rauf
    FOOD ANALYTICAL METHODS, 2014, 7 (04) : 872 - 878
  • [22] Monitoring of Zn(II), Cd(II), Pb(II) and Cu(II) During Refining of Some Vegetable Oils Using Differential Pulse Anodic Stripping Voltammetry
    Semahat Kucukkolbasi
    Osman Temur
    Huseyin Kara
    Abdul Rauf Khaskheli
    Food Analytical Methods, 2014, 7 : 872 - 878
  • [23] A Simple and Sensitive Method for the Detection of Trace Pb(II) and Cd(II) based on Nafion-coated Antimony Film Electrode
    Xu He
    Yang Ping
    Zheng Qiaoli
    Liu Jianshe
    Jin Litong
    CHINESE JOURNAL OF CHEMISTRY, 2010, 28 (11) : 2287 - 2292
  • [24] Ultra-sensitive simultaneous electrochemical detection of Zn(II), Cd(II) and Pb(II) based on the bismuth and graphdiyne film modified electrode
    Ai, Yijing
    Yan, Lijun
    Zhang, Siyue
    Ye, Xiang
    Xuan, Yongkang
    He, Shuhai
    Wang, Xianghui
    Sun, Wei
    MICROCHEMICAL JOURNAL, 2023, 184
  • [25] Ultra-sensitive simultaneous electrochemical detection of Zn(II), Cd(II) and Pb(II) based on the bismuth and graphdiyne film modified electrode
    Ai, Yijing
    Yan, Lijun
    Zhang, Siyue
    Ye, Xiang
    Xuan, Yongkang
    He, Shuhai
    Wang, Xianghui
    Sun, Wei
    MICROCHEMICAL JOURNAL, 2023, 184
  • [26] Simultaneous Determination of Hg(II), Cd(II), Pb(II) and Zn(II) by Anodic Stripping Voltammetry using Modified Carbon Paste Ionic Liquid Electrode
    Faridan, Ashkan
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (06): : 810 - 827
  • [27] Nitrogen-doped carbon dots as green materials for sensitive and selective detection of isorhamnetin
    Dong, Haonan
    Shang, Ge
    Zhang, Yi
    Hu, Sujuan
    He, Hongxing
    Li, Weili
    Deng, Xiujun
    Nie, Zhifeng
    Zhao, Sibiao
    MATERIALS TODAY SUSTAINABILITY, 2024, 27
  • [28] Sensitive detection of uranium in water samples using differential pulse adsorptive stripping voltammetry on glassy carbon electrode
    Zhiping Zhou
    Yueming Zhou
    Xizhen Liang
    Fang Xie
    Shujuan Liu
    Jianguo Ma
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 2049 - 2056
  • [29] Sensitive detection of uranium in water samples using differential pulse adsorptive stripping voltammetry on glassy carbon electrode
    Zhou, Zhiping
    Zhou, Yueming
    Liang, Xizhen
    Xie, Fang
    Liu, Shujuan
    Ma, Jianguo
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (03) : 2049 - 2056
  • [30] High performance ratiometric detection towards trace Cd(II) and Pb(II) utilizing in-situ bismuth modified nitrogen rich porous carbon/boron doped diamond composite electrode
    Zhou, Xuesong
    Gai, Zhigang
    Wang, Yibao
    Liu, Shousheng
    Zhang, Xueyu
    Guo, Fengxiang
    Zhang, Mei
    Zhang, Lili
    Jiang, Xin
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (02):