Development of Evaluation System Using Photoplethysmography Sensors for Intradialytic Hypotension Monitoring

被引:0
|
作者
Wu, Ming-Jui [1 ,2 ]
Yen, Lim Bee [2 ]
Wu, Jian-Xing [3 ]
Du, Yi-Chun [2 ]
Ciou, Wei-Siang [2 ]
Chen, Shi-Han [2 ]
Hu, Hsiang-Wei [4 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Internal Med, Tainan Branch, 427 Fuxing Rd, Tainan 710, Taiwan
[2] Southern Taiwan Univ Sci & Technol, Dept Elect Engn, 1 Nantai St, Tainan 710, Taiwan
[3] Natl Chin Yi Univ Technol, Dept Elect Engn, 57,Sec 2,Zhongshan Rd, Taichung 411, Taiwan
[4] Natl Cheng Kung Univ, Dept Biomed Engn, 1 Univ Rd, Tainan 701, Taiwan
关键词
hemodialysis (HD); blood pressure (BP); intradialytic hypotension (IDH); heart rate variability (HRV); arterial pressure (AP); HEMODIALYSIS;
D O I
10.18494/SAM.2020.2689
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Complications of hemodialysis (HD) treatment include hypotension, hypertension, imbalance syndrome, and chest pain. The incidence of hypotension ranges from 25 to 50%, making it as the most common complication during HD. Repeated hypotension causes blood stagnation and leads to excessive heart workload of patients. Moreover, clinical studies proposed that the incidence of hypotension has a high correlation with the rate of mortality. In clinical practice, blood pressure (BP) measurement by nursing staff every 30 to 60 min or the patient claiming of discomfort is required to detect intradialytic hypotension (IDH). In this study, we developed an evaluation system using photoplethysmography (PPG) sensors for IDH monitoring. The system acquired heart rate variability (HRV) from PPG sensors and arterial pressure (AP) from dialysis machines to provide an immediate classification of IDH risk. We divided IDH patients into three classes from low to high risk, with the third category having the highest risk. To verify the accuracy of the system, we designed a clinical trial to compare measurements obtained with the system with BP measurements taken by clinical staff. The results from 12 patients indicated that the accuracy of the proposed system was 90%, indicating its high potential to provide a simple and fast assistance system for assisting in the clinical evaluation of IDH.
引用
收藏
页码:1623 / 1632
页数:10
相关论文
共 50 条
  • [41] Continuous haematocrit monitoring during intradialytic hypotension: precipitous decline in plasma refill rates
    Schroeder, KL
    Sallustio, JE
    Ross, EA
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (03) : 652 - 656
  • [42] Evaluation of midodrine dosing for treatment of intradialytic hypotension in chronic hemodialysis patients.
    Barbato, R
    Jayamaha, S
    Wadhwa, NK
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 208A - 208A
  • [43] Photoplethysmography Based Remote Health Monitoring System
    Harbawi, Malek A.
    Ibrahimy, Muhammad I.
    Motakabber, S. M. A.
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA 2013), 2013,
  • [44] Stress Monitoring System using Sensors for Drivers
    Selvi, Senthamizh R.
    Aishwarya, J. V. R.
    Deepavarshini, S.
    Sudha, S.
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (13): : 317 - 322
  • [45] A Video based Heart Rate Monitoring System for Drivers Using Photoplethysmography Signal
    Hui, Ma Li
    Nisar, Humaira
    Ho, Yeap Kim
    Chiong, Teh Peh
    2018 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2018,
  • [46] Low central blood pressure and sympathetic activity predispose for the development of intradialytic hypotension
    Wu, Han-Kuei
    Chang, Ming-Yang
    Cheng, Hao-Min
    Hsu, Po-Chi
    Lo, Lun-Chien
    Chen, Li-Chuan
    Lin, Kang-Ping
    Chang, Hen-Hong
    MEDICINE, 2021, 100 (14) : E25299
  • [47] Development of Behavior Monitoring System for Honeybees in Hive Using RFID sensors and Image Processing
    Takahashi, Shinya
    Hashimoto, Koji
    Maeda, Sakashi
    Li, Yujie
    Tsarina, Naoyuki
    Ai, Hiroyuki
    2019 16TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER SCIENCE AND SOFTWARE ENGINEERING (JCSSE 2019), 2019, : 170 - 175
  • [48] Development Real Time Monitoring System of FTTH Using Fiber Bragg Grating Sensors
    Jung, So-Ki
    2019 ELEVENTH INTERNATIONAL CONFERENCE ON UBIQUITOUS AND FUTURE NETWORKS (ICUFN 2019), 2019, : 646 - 648
  • [49] Efficacy of Hemocontrol Biofeedback System in Intradialytic Hypotension-Prone Hemodialysis Patients
    Gil, Hyo-Wook
    Bang, Kitae
    Lee, So Young
    Han, Byoung Geun
    Kim, Jin Kuk
    Kim, Young Ok
    Song, Ho Cheol
    Kwon, Young Joo
    Kim, Yong-Soo
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (06) : 805 - 810
  • [50] Monitoring and evaluation of hypotension in the extremely preterm
    Ping, Ping
    Yu, Beimeng
    Xu, Renjie
    Zhao, Pingping
    He, Shuqi
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11