Toxoplasma gondii:: Enzyme-linked immunosorbent assay using different fragments of recombinant microneme protein 1 (MIC1) for detection of immunoglobulin G antibodies

被引:38
|
作者
Holec, Lucyna [1 ]
Gasior, Atur [1 ]
Brillowska-Dabrowska, Anna [1 ]
Kur, Jozef [1 ]
机构
[1] Gdansk Univ Technol, Fac Chem, Dept Microbiol, PL-80952 Gdansk, Poland
关键词
ELISA; MIC1; recombinant antigen; serological detection; toxoplasmosis;
D O I
10.1016/j.exppara.2007.12.002
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Three different fragments of microneme I protein termed, r-MIC1ex2, r-MIC1ex34 and r-MIC1 of Toxoplasma gondii, were expressed in Escherichia coli as fusion proteins containing six histidyl residues at N- and C-terminal. After purification by metal affinity chromatography, these recombinant proteins were tested for their usefulness as antigens in an enzyme-linked immunosorbent assay for the detection of immunoglobulin G. Ninety-eight sera from patients with different stages of invasion and 24 sera from seronegative patients were examined. There was no significant difference observed in the antigenicity for human serum samples from patients with acute toxoplasmosis between three recombinant types of MIC1 antigen (96.1% for r-MIC1ex2 antigen and 100% for both r-MIC1ex34 and r-MIC1 proteins). Sera from chronic infections (with low titers of IgG antibody) showed significant lower sensitivity, especially for r-MIC1ex34 and r-MIC1 antigens (75%, 52.7% and 36.1% for r-MIC1ex2, r-MIC1ex34 and r-MIC1, respectively). These results indicate that the strongest antigenic region of the MIC1 is encoding by the second exon of micl gene. When r-MIC1ex2 (N-terminal fragment of protein) was combined with MAGI (matrix antigen) and MIC3 (microneme 3 protein), the sensitivity increased to 88.9%. This result was comparable to an ELISA using a Toxoplasma lysate antigen (TLA) and two combinations of recombinant antigens: M1 (GRA1 + GRA7 + SAG1) and M2 (P35 + SAG2 + GRA6) with the sensitivity for serum samples tested 94.4%, 88.9% and 94.4%, respectively. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] INTERLABORATORY EVALUATION OF INDIRECT ENZYME-LINKED-IMMUNOSORBENT-ASSAY, ANTIBODY CAPTURE ENZYME-LINKED-IMMUNOSORBENT-ASSAY, AND IMMUNOBLOTTING FOR DETECTION OF IMMUNOGLOBULIN-M ANTIBODIES TO TOXOPLASMA-GONDII
    HERBRINK, P
    VANLOON, AM
    ROTMANS, JP
    VANKNAPEN, F
    VANDIJK, WC
    JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (01) : 100 - 105
  • [32] Detection of Antibodies against Feline Morbillivirus by Recombinant Matrix Enzyme-Linked Immunosorbent Assay
    Chaiyasak, Surangkanang
    Piewbang, Chutchai
    Ratthanophart, Jadsada
    Techakriengkrai, Navapon
    Rattanaporn, Kittipong
    Techangamsuwan, Somporn
    VIRUSES-BASEL, 2024, 16 (08):
  • [33] ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR THE DETECTION OF CIRCULATING ANTIGENS OF TOXOPLASMA-GONDII IN THE SERUM OF CATS
    LAPPIN, MR
    GREENE, CE
    PRESTWOOD, AK
    DAWE, DL
    TARLETON, RL
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1989, 50 (09) : 1586 - 1590
  • [34] DETECTION OF CIRCULATING ANTIGEN DURING ACUTE INFECTIONS WITH TOXOPLASMA-GONDII BY ENZYME-LINKED IMMUNOSORBENT ASSAY
    VANKNAPEN, F
    PANGGABEAN, SO
    JOURNAL OF CLINICAL MICROBIOLOGY, 1977, 6 (06) : 545 - 547
  • [35] Immunoglobulin M enzyme-linked immunosorbent assay using recombinant polypeptides for diagnosis of dengue
    Videa, E
    Coloma, MJ
    dos Santos, FB
    Balmaseda, A
    Harris, E
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (07) : 882 - 884
  • [36] The MIC1 microneme protein of Toxoplasma gondii contains a duplicated receptor-like domain and binds to host cell surface
    Fourmaux, MN
    Achbarou, A
    MercereauPuijalon, O
    Biderre, C
    Briche, I
    Loyens, A
    OdbergFerragut, C
    Camus, D
    Dubremetz, JF
    MOLECULAR AND BIOCHEMICAL PARASITOLOGY, 1996, 83 (02) : 201 - 210
  • [37] ENZYME-LINKED PROTEIN-A - ENZYME-LINKED IMMUNOSORBENT ASSAY REAGENT FOR DETECTION OF HUMAN IMMUNOGLOBULIN-G AND VIRUS-SPECIFIC ANTIBODY
    MADORE, HP
    BAUMGARTEN, A
    JOURNAL OF CLINICAL MICROBIOLOGY, 1979, 10 (04) : 529 - 532
  • [38] NORMALIZED ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR DETERMINING IMMUNOGLOBULIN-G ANTIBODIES TO CYTOMEGALOVIRUS
    KIEFER, DJ
    PHELPS, DA
    HALBERT, SP
    JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (01) : 33 - 39
  • [39] Recombinant nucleoprotein-based enzyme-linked Immunosorbent assay for detection of immunoglobulin G antibodies to Crimean-Congo hemorrhagic fever virus
    Saijo, M
    Qing, T
    Niikura, M
    Maeda, A
    Ikegami, T
    Prehaud, C
    Kurane, I
    Morikawa, S
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (05) : 1587 - 1591
  • [40] Enzyme-linked immunosorbent assay detection of microcystins using new monoclonal antibodies
    Pyo, D
    Lee, J
    Choi, E
    JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2004, 25 (03): : 227 - 239