Since being operation of +/- 500kV Gezhouba - Nanqiao (GZB - NQ) HVDC Link, China, the smoothing reactor and the capacitors of DC filters were faulted for many times for the reasons of design,construction, and the others. In order to solve it, the method of harmonics suppression and regulating of passive filters is presented using active DC filter on the DC-side of GZB Converter Station in this paper. The active de filter is connected at the bottom of one existing passive de filters at GZB converter station. The construction and control strategies of active DC filter, as well as the principle of regulating load for passive filter are presented. The digital simulation results show that the practical feasibility of control technique and regulating load scheme for passive filters proposed in this paper.
引用
收藏
页码:1560 / 1564
页数:5
相关论文
共 33 条
  • [11] Study of DC-side voltage of new injection type hybrid active power filter
    Zhao, Wei
    Luo, An
    Fan, Ruixiang
    Tang, Ci
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (05): : 128 - 133
  • [12] Research on DC-side Voltage Fuzzy Control Method of Shunt Active Power Filter
    Xi Zi-qiang
    Zhang Jia
    Xiong Wei-wei
    Qi Lei
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [13] Design Considerations for Maintaining DC-Side Voltage of Hybrid Active Power Filter With Injection Circuit
    Luo, An
    Shuai, Zhikang
    Shen, Z. John
    Zhu, Wenji
    Xu, Xianyong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) : 75 - 84
  • [14] The DC-side active filter with dual-buck full-bridge inverter for wind generators
    Chen, Xiao-Qiang
    Zhao, Shou-Wang
    Wang, Ying
    ARCHIVES OF ELECTRICAL ENGINEERING, 2018, 67 (02) : 263 - 277
  • [15] ACTIVE DC FILTER FOR HVDC SYSTEM - A TEST INSTALLATION IN THE KONTI-SKAN DC LINK AT LINDOME CONVERTER STATION
    ZHANG, WY
    ASPLUND, G
    ABERG, A
    LEMAY, J
    JONSSON, U
    LOOF, O
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1599 - 1606
  • [16] A Motor CM Impedance Based Transformerless Active EMI Filter for DC-Side Common-Mode EMI Suppression in Motor Drive System
    Zhang, Yechi
    Li, Qiao
    Jiang, Dong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (10) : 10238 - 10248
  • [17] Analysis on Influence Mechanism of DC-side Voltage Fluctuation on Circulating Current of Modular Multilevel Converter and Its Suppression Method
    Zhang X.
    Han M.
    Yang J.
    Meng X.
    Qiu Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (15): : 122 - 131
  • [18] Minimum DC-Side Voltage Design for Three-Phase Four-Wire Active Power Filter
    Wang, Yu
    Xie, Yunxiang
    Liu, Xiang
    Hu, Jianbing
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 990 - 994
  • [19] Analysis and Active Suppression of AC- and DC-Side Instabilities in Grid-Connected Current-Source Converter-Based Photovoltaic System
    Radwan, Amr Ahmed A.
    Mohamed, Yasser Abdel-Rady I.
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2013, 4 (03) : 630 - 642
  • [20] Active Filter-Based Hybrid On-Chip DC-DC Converter for Point-of-Load Voltage Regulation
    Koese, Selcuk
    Tam, Simon
    Pinzon, Sally
    McDermott, Bruce
    Friedman, Eby G.
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2013, 21 (04) : 680 - 691