The Graphene/L-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium

被引:11
|
作者
Song, Yu [1 ,2 ]
Bian, Chao [1 ]
Tong, Jianhua [1 ]
Li, Yang [1 ]
Xia, Shanghong [1 ]
机构
[1] Chinese Acad Sci, State Key Lab Transducer Technol, Inst Elect, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
来源
MICROMACHINES | 2016年 / 7卷 / 06期
关键词
graphene/L-cysteine/gold electrode; glass carbon electrode; boron-doped diamond electrode; differential pulse stripping voltammetry; cadmium; HEAVY-METAL IONS; ELECTROCHEMICAL SENSOR; MERCURY; LEAD; PRECONCENTRATION; WATER; SPECTROMETRY; ADSORPTION; SPECIATION; GEL;
D O I
10.3390/mi7060103
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/L-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/L-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 mu g/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA.mm(-2).mu g(-1).L for, respectively, the BDD electrode, the GCE, and the Gr/L-cysteine/gold electrode. It was shown that the Gr/L-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Adsorptive stripping differential pulse voltammetry determination of rivastigmine at graphene nanosheet-gold nanoparticle/carbon paste electrode
    Kalambate, Pramod K.
    Biradar, Madan R.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 757 : 150 - 158
  • [32] L-cysteine voltammetry at a carbon paste electrode bulk-modified with ferrocenedicarboxylic acid
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Beitollahi, Hadi
    ELECTROANALYSIS, 2007, 19 (17) : 1822 - 1830
  • [33] Ex-situ plating bismuth film on platinum electrode for the determination of trace lead and cadmium by differential pulse stripping voltammetry
    Gong Wei-Lei
    Du Xiao-Yan
    Wang Shu-Ran
    Jiang Xian-Chen
    Qian, Sun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (02) : 177 - 181
  • [34] Gold nanoparticle included graphene oxide modified electrode: Picomole detection of metal ions in seawater by stripping voltammetry
    İlknur Üstündağ
    Aslı Erkal
    Tamer Koralay
    Yusuf Kağan Kadıoğlu
    Seungwon Jeon
    Journal of Analytical Chemistry, 2016, 71 : 685 - 695
  • [35] Gold nanoparticle included graphene oxide modified electrode: Picomole detection of metal ions in seawater by stripping voltammetry
    Ustundag, Ilknur
    Erkal, Asli
    Koralay, Tamer
    Kadioglu, Yusuf Kagan
    Jeon, Seungwon
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (07) : 685 - 695
  • [36] Determination of chromium(III) by differential pulse stripping voltammetry at a chitosan-gold nanocomposite modified screen printed electrode
    Wu, Shixin
    Sekar, Nadia Chandra
    Tan, Swee Ngin
    Xie, Hong
    Ng, Sum Huan
    ANALYTICAL METHODS, 2016, 8 (05) : 962 - 967
  • [37] Simultaneous detection of metronidazole and chloramphenicol by differential pulse stripping voltammetry using a silver nanoparticles/sulfonate functionalized graphene modified glassy carbon electrode
    Zhai, Haiyun
    Liang, Zhixian
    Chen, Zuanguang
    Wang, Haihang
    Liu, Zhenping
    Su, Zihao
    Zhou, Qing
    ELECTROCHIMICA ACTA, 2015, 171 : 105 - 113
  • [38] Simultaneous Determination of Trace Zinc(II) and Cadmium(II) by Differential Pulse Anodic Stripping Voltammetry Using a MWCNTs-NaDBS Modified Stannum Film Electrode
    Tian, Yun Qing
    Li, Nian Bing
    Luo, Hong Qun
    ELECTROANALYSIS, 2009, 21 (23) : 2584 - 2589
  • [39] Amperometric L-cysteine Sensor Using a Gold Electrode Modified with Thiolated Catechol
    Xu, Haitao
    Li, Chaorong
    Song, Dongcheng
    Xu, Xiaolin
    Zhao, Yan
    Liu, Xiaoying
    Su, Zhaohong
    ELECTROANALYSIS, 2017, 29 (10) : 2410 - 2416
  • [40] Barium Hydrogen Phosphate Modified Carbon Paste Electrode for the Simultaneous Determination of Cadmium and Lead by Differential Pulse Anodic Stripping Voltammetry
    Sheela, T.
    Basavanna, S.
    Viswanatha, R.
    Kalachar, H. C. B.
    Naik, Y. Arthoba
    ELECTROANALYSIS, 2011, 23 (05) : 1150 - 1157