Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice

被引:41
|
作者
Gabriele, Michelle L. [1 ,2 ,3 ]
Ishikawa, Hiroshi [1 ,2 ]
Schuman, Joel S. [1 ,2 ,3 ]
Bilonick, Richard A. [1 ]
Kim, Jongsick [1 ,2 ]
Kagemann, Larry [1 ,2 ]
Wollstein, Gadi [1 ]
机构
[1] Univ Pittsburgh, Inst Eye & Ear, UPMC Eye Ctr, Ophthalmol & Visual Sci Res Ctr,Dept Ophthalmol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA 15213 USA
[3] Carnegie Mellon Univ, Ctr Neural Basis Cognit, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
FIBER LAYER THICKNESS; LONGITUDINAL VARIABILITY; GLAUCOMATOUS EYES; RODENT RETINA; MOUSE RETINA; NERVE HEAD; DEGENERATION; MODEL; DISC; OCT;
D O I
10.1167/iovs.10-5662
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To test the reproducibility of spectral-domain optical coherence tomography (SD-OCT) total retinal thickness (TRT) measurements in mice. METHODS. C57Bl/6 mice were anesthetized, and three repeated volumetric images were acquired in both eyes with SD-OCT (250 A-scans x 250 frames x 1024 samplings), centered on the optic nerve head (ONH). The mice were repositioned between scans. TRT was automatically measured within a sampling band of retinal thickness with radii of 55 to 70 pixels, centered on the ONH by using custom segmentation software. The first volumetric image acquired in a given eye was used to register the remaining two SD-OCT images by manually aligning the en face images with respect to rotation and linear translation. Linear mixed-effects models were fitted to global and quadrant thicknesses, taking into account the clustering between eyes, to assess imprecision (measurement reproducibility). RESULTS. Twenty-six eyes of 13 adult mice (age 13 weeks) were imaged. The mean global TRT across all eyes was 298.21 mu m, with a mouse heterogeneity standard deviation (SD) of 4.88 mu m (coefficient of variation [CV] = 0.016), an eye SD of 3.32 mu m (CV = 0.011), and a device-related imprecision SD of 2.33 mu m (CV = 0.008). The superior quadrant had the thickest mean TRT measurement (310.38 mu m) and the highest (worst) imprecision SD (3.13 mu m; CV = 0.010), and the inferior quadrant had the thinnest mean TRT (291.55 mu m). The quadrant with the lowest (best) imprecision SD was in the nasal one (2.06 mu m; CV = 0.007). CONCLUSIONS. Good reproducibility was observed for SD-OCT retinal thickness measurements in mice. SD-OCT may be useful for in vivo longitudinal studies in mice. (Invest Ophthalmol Vis Sci. 2010; 51: 6519-6523) DOI:10.1167/iovs.10-5662
引用
收藏
页码:6519 / 6523
页数:5
相关论文
共 50 条
  • [41] Reproducibility of retinal thickness measurements using optical coherence tomography (OCT)
    Liebmann, JM
    Baumann, M
    Gentile, RC
    DeLuca, R
    Ozols, A
    Chew, SJ
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4464 - 4464
  • [42] Assessment of corneal layers thickness with spectral-domain optical coherence tomography
    Segura, F.
    de la Fuente, C. Lopez
    Sachez-Cano, A.
    Orduna, E.
    Del Buey, M.
    Pinilla, I.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [43] Choroidal thickness in preeclampsia measured by spectral-domain optical coherence tomography
    Benfica, Camila Zanella
    Zanella, Teresinha
    Farias, Lucas Brandolt
    Rocha Oppermann, Maria Lucia
    Santos Canani, Luis Henrique
    Lavinsky, Daniel
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (09) : 2069 - 2076
  • [44] Spectral-domain optical coherence tomography characteristics of cystic retinal tuft
    Haidong Li
    Lifeng Chen
    Meng’ai Wu
    Bin Zheng
    BMC Ophthalmology, 22
  • [45] Retinal Surface Prediction in Ophthalmic Spectral-Domain Optical Coherence Tomography
    Wu, Jing
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [46] Spectral-domain optical coherence tomography characteristics of cystic retinal tuft
    Li, Haidong
    Chen, Lifeng
    Wu, Meng'ai
    Zheng, Bin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [47] Spectral-Domain Optical Coherence Tomography Documentation of Transsynaptic Retinal Degeneration
    Schwartz, Stephen G.
    Pasol, Joshua
    Lam, Byron L.
    Flynn, Harry W., Jr.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (08): : 768 - 772
  • [48] Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems
    Branchini, Lauren
    Regatieri, Caio V.
    Flores-Moreno, Ignacio
    Baumann, Bernhard
    Fujimoto, James G.
    Duker, Jay S.
    OPHTHALMOLOGY, 2012, 119 (01) : 119 - 123
  • [49] Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines
    Koay, Chiang Ling
    Quo, Matthew Justin
    Subrayan, Visvaraja
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (03) : 655 - 671
  • [50] Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines
    Chiang Ling Koay
    Matthew Justin Quo
    Visvaraja Subrayan
    International Ophthalmology, 2017, 37 : 655 - 671