Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy

被引:41
|
作者
Martinez-Rovira, I. [1 ,2 ]
Sempau, J. [2 ]
Fernandez-Varea, J. M. [3 ]
Bravin, A. [1 ]
Prezado, Y. [1 ]
机构
[1] European Synchrotron Radiat Facil, Biomed Beamline ID17, F-38043 Grenoble, France
[2] Univ Politecn Cataluna, Inst Tecn Energet, E-08028 Barcelona, Spain
[3] Univ Barcelona, Fac Fis ECM & ICC, E-08028 Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 15期
关键词
LINEAR-QUADRATIC MODEL; PRIMARY BRAIN-TUMORS; MICROPLANAR BEAM; STEREOTACTIC RADIOTHERAPY; ADJUVANT TEMOZOLOMIDE; 9L GLIOSARCOMA; SYNCHROTRON; SIMULATION; CONCOMITANT; GLIOBLASTOMA;
D O I
10.1088/0031-9155/55/15/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to define safe irradiation protocols in microbeam radiation therapy. The intense synchrotron-generated x-ray beam used for the treatment is collimated and delivered in an array of 50 mu m-sized rectangular fields with a centre-to-centre distance between microplanes of 400 mu m. The absorbed doses received by the tumour and the healthy tissues in a human head phantom have been assessed by means of Monte Carlo simulations. The identification of safe dose limits is carried out by evaluating the maximum peak and valley doses achievable in the tumour while keeping the valley doses in the healthy tissues under tolerances. As the skull receives a significant fraction of the dose, the dose limits are referred to this tissue. Dose distributions with high spatial resolution are presented for various tumour positions, skull thicknesses and interbeam separations. Considering a unidirectional irradiation (field size of 2x2 cm(2)) and a centrally located tumour, the largest peak and valley doses achievable in the tumour are 55 Gy and 2.6 Gy, respectively. The corresponding maximum valley doses received by the skin, bone and healthy brain are 4 Gy, 14 Gy and 7 Gy (doses in one fraction), respectively, i.e. within tolerances (5% probability of complication within 5 years).
引用
收藏
页码:4375 / 4388
页数:14
相关论文
共 50 条
  • [21] Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam
    Kaplan, GI
    Rosenfeld, AB
    Allen, BJ
    Booth, JT
    Carolan, MG
    Holmes-Siedle, A
    MEDICAL PHYSICS, 2000, 27 (01) : 239 - 244
  • [22] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [23] Dosimetry and Monte Carlo modelling of the Papillon plus contact X-ray brachytherapy device
    Colson, Dries
    Yalvac, Burak
    Weterings, Jan
    Verrijssen, An-Sofie
    van Haaren, Paul
    Bellezzo, Murillo
    Berbee, Maaike
    Van Limbergen, Evert J.
    Croce, Olivier
    Verhaegen, Frank
    Reniers, Brigitte
    BRACHYTHERAPY, 2024, 23 (05) : 535 - 548
  • [24] Monte Carlo simulations for X-ray breast dosimetry using homogeneous and heterogeneous phantoms
    Tucciariello, R. M.
    Barca, P.
    Del Sarto, D.
    Lamastra, R.
    Traino, A. C.
    Fantacci, M. E.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2021, 44 (4-5):
  • [25] Monte Carlo and 60Co-based kilovoltage x-ray dosimetry methods
    Lawless, Michael J.
    Dimaso, Lianna
    Palmer, Benjamin
    Micka, John
    Culberson, Wesley S.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2018, 45 (12) : 5564 - 5576
  • [26] Dosimetric studies of microbeam radiation therapy (MRT) with Monte Carlo simulations
    Siegbahn, EA
    Bräuer-Krisch, E
    Stepanek, J
    Blattmann, H
    Laissue, JA
    Bravin, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 54 - 58
  • [27] Monte Carlo modelling of a silicon strip detector for microbeam radiation therapy
    Cullen, Ashley
    Lerch, Michael
    Petasecca, Marco
    Rosenfeld, Anatoly
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1646 - 1649
  • [28] Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube
    Winter, Johanna
    Galek, Marek
    Matejcek, Christoph
    Wilkens, Jan J.
    Aulenbacher, Kurt
    Combs, Stephanie E.
    Bartzsch, Stefan
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 : 74 - 81
  • [29] Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation
    Chicilo, F.
    Hanson, A. L.
    Geisler, F. H.
    Belev, G.
    Edgar, A.
    Ramaswami, K. O.
    Chapman, D.
    Kasap, S. O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07):
  • [30] Dosimetry Equivalence Between X-Ray and Gamma-Ray Irradiation with Validated Monte Carlo Simulations
    Rodriguez, J.
    Peter, R.
    Yang, J.
    Serrano, J.
    Nostrand, C.
    Steri, V.
    Gunther, C.
    Seo, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E977 - E977