Determination of bicyclol in dog plasma using liquid chromatography-tandem mass spectrometry

被引:5
|
作者
Sheng, Li
Hu, Jinping
Wang, Baolian
Chen, Hui
Li, Yan [1 ]
机构
[1] Chinese Acad Med Sci, Inst Mat Med, Beijing 100050, Peoples R China
关键词
Bicyclol; LC/MS/MS; Pharmacokinetic; Dog; LIVER-INJURY; METABOLITES; VALIDATION; DRUG;
D O I
10.1016/j.jchromb.2010.06.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and accurate method for determination of bicyclol in dog plasma was developed. Thermo Scientific TSQ Quantum triple quadrupole system with multiple ion monitoring (MIM) positive scanning mode was applied. Bicyclol and DDB (IS) sodium adduct molecular ions were monitored at m/z 413 and m/z 441 in both Q1 and Q3, respectively. The collision energy in Q2 was set to 15 eV. Precipitation method was employed in the extraction of bicyclol and DDB from the biological matrix. The method was validated over 1-500 ng/mL for bicyclol. The recovery was 96.5-109.5%, and the limit of quantitation (LOQ) detection was 1 ng/mL for bicyclol. The intra- and inter-day precision of the method at three concentrations was 3.3-14.3% with accuracy of 99.9-109.0%. The method was successfully applied to bioequivalence studies of bicyclol controlled-release formulation to obtain the pharmacokinetic parameters. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2106 / 2110
页数:5
相关论文
共 50 条
  • [31] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [32] Simple and sensitive determination of nisoldipine in plasma using liquid chromatography-tandem mass spectrometry
    Kang, Wonku
    [J]. ANALYTICAL SCIENCES, 2006, 22 (12) : 1597 - 1599
  • [33] Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry
    Badenhorst, D
    Sutherland, FCW
    de Jager, AD
    Scanes, T
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (01): : 91 - 98
  • [34] Determination of limonin in dog plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Liu, Shi-jia
    Zhou, Ling
    Zhang, Jun
    Yu, Bo-yang
    Li, Chang-yin
    Liu, Zi-xiu
    Ju, Wen-zheng
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) : 515 - 519
  • [35] Determination of dalcetrapib by liquid chromatography-tandem mass spectrometry
    Heinig, Katja
    Bucheli, Franz
    Kuhlmann, Olaf
    Zell, Manfred
    Paehler, Axel
    Zwanziger, Elke
    Gross, Guenter
    Tardio, Joseph
    Ishikawa, Tomohiro
    Yamashita, Tomoko
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 314 - 324
  • [36] Determination of stanozolol in hair using liquid chromatography-tandem mass spectrometry
    Xiang Ping
    Shen Min
    Shen Baohua
    Yan Hui
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 469 - 472
  • [37] Determination of alprazolam by liquid chromatography-tandem mass spectrometry
    Svinarov, DA
    Kotzev, C
    Kassabova, LV
    [J]. CLINICA CHIMICA ACTA, 2005, 355 : S421 - S421
  • [38] Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry
    Mendonza, A
    Gohh, R
    Akhlaghi, F
    [J]. THERAPEUTIC DRUG MONITORING, 2004, 26 (05) : 569 - 575
  • [39] Determination of protease inhibitors using liquid chromatography-tandem mass spectrometry
    Frerichs, VA
    DiFrancesco, R
    Morse, GD
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 393 - 403
  • [40] Determination of nicotine and cotinine in rat plasma by liquid chromatography-tandem mass spectrometry
    Stolker, AAM
    Niesing, W
    Hogendoorn, EA
    Rambali, AB
    Vleeming, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 35 - 43