Performance of reduction on particle emission by combining the charged water drop atomization and electric field in wet electrostatic precipitator

被引:16
|
作者
Teng, Chenzi [1 ,2 ]
Li, Jian [2 ]
机构
[1] Beijing Acad Sci & Technol, Beijing Res Ctr Urban Syst Engn, Beijing 100089, Peoples R China
[2] Beijing Univ Technol, Coll Environm & Energy Engn, Key Lab Beijing Reg Air Pollut Control, Beijing 100124, Peoples R China
关键词
Wet electrostatic precipitator; Charged water drop atomization; Electric field; Combined effect; Particle removal; Water consumption; SULFURIC-ACID AEROSOL; COLLECTION; FINE; ELECTROSPRAY; REMOVAL; ENHANCEMENT; SUBMICRON; DISCHARGE;
D O I
10.1016/j.psep.2021.09.035
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a wet electrostatic precipitator (WESP) with combination of electric field and charged water drop atomization was designed for fine particle collection, which replaced the traditional water film and mechanically spray. The removal performance was evaluated considering applied voltage, water flow rate, gas residence time, dust concentration, and continuous operation time. Results indicated that supplying charged droplets could acquire higher discharge current and better agglomeration effect than the dry type. The maximum penetration ratio was reduced from 3.8%-11.56% in the dry ESP to 3.58%-8.6% with charged droplets, as the applied voltage increased from 30 kV to 60 kV. Meanwhile, increase of water flow rate improved the total removal efficiency. The advantage of the WESP was more obvious under short gas residence time. The route of synergistically increasing gas residence time and applied voltage could largely reduce the penetration ratio, which decreased from 6.99%-19.81% to 1.03%-2.43% as they were enhanced from 1.50 s and 30 kV to 3.33 s and 60 kV. Increasing the dust concentration led to the trend that the total removal efficiency first increasing and then decreasing gradually, resulted from combined mechanisms of particle agglomeration and suppression of corona current. Moreover, the atomization of charged water drop maintained the advantage on particle removal under continuous operation, and the efficiency drop after long-term operation could be avoided. In particular, the WESP achieved significant reduction on water consumption compared to conventional large-scale and on-site WESPs in application with equivalent levels of removal efficiency. (c) 2021 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:543 / 554
页数:12
相关论文
共 24 条
  • [21] Charged particle acceleration by electrostatic turbulent structures in regions with field-aligned electric current in the auroral magnetosphere
    Bespalov, PA
    Misonova, VG
    PHYSICS AND CHEMISTRY OF THE EARTH PART C-SOLAR-TERRESTIAL AND PLANETARY SCIENCE, 2001, 26 (1-3): : 113 - 119
  • [22] The mechanism of viscosity reduction of waxy oils induced by the electric field: A correlation between the viscosity reduction and the charged particle accumulation on wax particles
    Xie, Yiwei
    Li, Hongying
    Huang, Qian
    Su, Yang
    Zhang, Chaoyue
    Xu, Miaomiao
    Han, Shanpeng
    Zhang, Jinjun
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2023, 642 : 373 - 379
  • [23] Partitioning and Emission of Hazardous Trace Elements in a 100 MW Coal-Fired Power Plant Equipped with Selective Catalytic Reduction, Electrostatic Precipitator, and Wet Flue Gas Desulfurization
    Zhao, Shilin
    Duan, Yufeng
    Li, Chunfeng
    Li, Yaning
    Chen, Cong
    Liu, Meng
    Lu, Jianhong
    ENERGY & FUELS, 2017, 31 (11) : 12383 - 12389
  • [24] Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 4. PM Removal Performance of Wet Electrostatic Precipitators
    Xu, Yishu
    Liu, Xiaowei
    Cui, Jiang
    Chen, Dong
    Xu, Minghou
    Pan, Siwei
    Zhang, Kai
    Gao, Xiangpeng
    ENERGY & FUELS, 2016, 30 (09) : 7465 - 7473