An experimental study of flow distribution and separation performance in a UU-type mini-hydrocyclone group

被引:26
|
作者
Lv, Wen-jie [1 ]
Huang, Cong [2 ]
Chen, Jian-qi [1 ]
Liu, Hong-lai [3 ]
Wang, Hua-lin [1 ]
机构
[1] E China Univ Sci & Technol, Environm Protect Key Lab Environm Risk Assessment, Shanghai 200237, Peoples R China
[2] Hangzhou Hangyang Co Ltd, Hangzhou 310014, Zhejiang, Peoples R China
[3] E China Univ Sci & Technol, State Key Lab Chem Engn, Shanghai 200237, Peoples R China
基金
美国国家科学基金会;
关键词
Separation precision; Mini-hydrocyclone group; Non-uniformity degree; Fish hook; PRESSURE-DROP; PARTICLES; REMOVAL; CLASSIFICATION; DESIGN; FLUID; FIELD;
D O I
10.1016/j.seppur.2015.06.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In industrial applications, it is common to use multiple mini-hydrocyclones in parallel to improve separation precision. Maintaining the uniformity of flow distribution and the low pressure drop of the mini-hydrocyclone group becomes a major challenge. This is because that any non-uniformity reduces the separation performance and that high pressure drop increases the system's power consumption due to increasing of pump power. In this paper, based on the theoretical analysis in our previous work (Huang et al., 2013), we performed a series of experiments in a UU-type mini-hydrocyclone group. It aims to acquire the characteristics of pressure drop and flow distribution, and to evaluate the separation performance in a laboratory scale. In single-phase experiments, it was observed that the non-uniformity degree of pressure drop and flow distribution was the lowest for an inlet pressure of 0.10 MPa, and a relatively uniform pressure drop and flow distribution were respectively obtained with the maximum fluctuations of 7.2% and 3.6%. In solid liquid separation experiments, the mini-hydrocyclone group was employed to separate the catalysts from the carrying fluids. As the catalyst concentration is increased, the separation efficiency of the mini-hydrocyclone group gradually increased as well, from 74.8% to 82.6%. Furthermore, the fish hook phenomenon existed in the grade efficiency curve of the mini-hydrocyclone group. The cut size d(50) ranged from 1.78 mu m to 1.92 mu m, in good agreement with that for single mini-hydrocyclone. Results indicated that the mini-hydrocyclone group can meet the requirements of satisfying separation efficiency and smaller cut-size precision in industry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [31] Experimental study of the relationship between separation performance and lengths of vortex finder of a novel de-foulant hydrocyclone with continuous underflow and reflux function
    Ni, Long
    Tian, Jinyi
    Zhao, Jianing
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (01) : 142 - 154
  • [32] Experimental Study of Rotor Flow Separation Control using a New Type of Dielectric Barrier Discharge Plasma Actuator
    Hu Xu
    Gao Chao
    Hao Jiangnan
    Zhang Zhengke
    Xue Ming
    Yan Rihua
    [J]. JOURNAL OF THERMAL SCIENCE, 2019, 28 (02) : 354 - 359
  • [33] Experimental Study of Rotor Flow Separation Control using a New Type of Dielectric Barrier Discharge Plasma Actuator
    HU Xu
    GAO Chao
    HAO Jiangnan
    ZHANG Zhengke
    XUE Ming
    YAN Rihua
    [J]. Journal of Thermal Science, 2019, 28 (02) : 354 - 359
  • [34] Experimental Study of Rotor Flow Separation Control using a New Type of Dielectric Barrier Discharge Plasma Actuator
    Xu Hu
    Chao Gao
    Jiangnan Hao
    Zhengke Zhang
    Ming Xue
    Rihua Yan
    [J]. Journal of Thermal Science, 2019, 28 : 354 - 359
  • [35] Enhancing thermal-hydraulic performance of counter flow mini-channel heat sinks utilizing secondary flow: Numerical study with experimental validation
    Tikadar, Amitav
    Paul, Titan C.
    Oudah, Saad K.
    Abdulrazzaq, Nabeel M.
    Salman, Azzam S.
    Khan, Jamil A.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 111
  • [36] Experimental study on the influence of inlet pressure on the flow parameters at the reverse flow boundary of vortex tube and its relation with energy separation performance
    Chen, Guangming
    Jiang, Guannan
    Tang, Liming
    Li, Nian
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2024, 156
  • [37] Experimental study on the performance of a novel structure for two-phase flow distribution in parallel vertical channels
    Yuan, P.
    Jiang, G. B.
    He, Y. L.
    Yi, X. L.
    Tao, W. Q.
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2013, 53 : 65 - 74
  • [38] Experimental study on the performance of a mini-scale Y-type mixer with two liquid metal-enabled pumps
    Jafarpour, A. Mohammad
    Khosroshahi, A. Rostamzadeh
    Hanifi, M.
    Moghanlou, F. Sadegh
    [J]. PHYSICS OF FLUIDS, 2022, 34 (11)
  • [39] An Experimental Study on the Energy Separation Performance of a Counter-Flow Ranque–Hilch Vortex Tube with Different Hot Tubes
    Gopu Govindaraj
    Kumaresan Govindarajan
    Swaminathan Mangudi Rangaswamy
    [J]. Iranian Journal of Science and Technology, Transactions of Mechanical Engineering, 2024, 48 : 567 - 579
  • [40] AN EXPERIMENTAL STUDY OF TRANSITIONAL FLOW FRICTION AND HEAT TRANSFER PERFORMANCE OF A CHANNEL WITH STAGGERED ARRAYS OF MINI-SCALE SHORT PIN FINS
    Rao, Yu
    Wan, Chaoyi
    Zang, Shusheng
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 277 - 285