An experimental study of flow distribution and separation performance in a UU-type mini-hydrocyclone group

被引:26
|
作者
Lv, Wen-jie [1 ]
Huang, Cong [2 ]
Chen, Jian-qi [1 ]
Liu, Hong-lai [3 ]
Wang, Hua-lin [1 ]
机构
[1] E China Univ Sci & Technol, Environm Protect Key Lab Environm Risk Assessment, Shanghai 200237, Peoples R China
[2] Hangzhou Hangyang Co Ltd, Hangzhou 310014, Zhejiang, Peoples R China
[3] E China Univ Sci & Technol, State Key Lab Chem Engn, Shanghai 200237, Peoples R China
基金
美国国家科学基金会;
关键词
Separation precision; Mini-hydrocyclone group; Non-uniformity degree; Fish hook; PRESSURE-DROP; PARTICLES; REMOVAL; CLASSIFICATION; DESIGN; FLUID; FIELD;
D O I
10.1016/j.seppur.2015.06.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In industrial applications, it is common to use multiple mini-hydrocyclones in parallel to improve separation precision. Maintaining the uniformity of flow distribution and the low pressure drop of the mini-hydrocyclone group becomes a major challenge. This is because that any non-uniformity reduces the separation performance and that high pressure drop increases the system's power consumption due to increasing of pump power. In this paper, based on the theoretical analysis in our previous work (Huang et al., 2013), we performed a series of experiments in a UU-type mini-hydrocyclone group. It aims to acquire the characteristics of pressure drop and flow distribution, and to evaluate the separation performance in a laboratory scale. In single-phase experiments, it was observed that the non-uniformity degree of pressure drop and flow distribution was the lowest for an inlet pressure of 0.10 MPa, and a relatively uniform pressure drop and flow distribution were respectively obtained with the maximum fluctuations of 7.2% and 3.6%. In solid liquid separation experiments, the mini-hydrocyclone group was employed to separate the catalysts from the carrying fluids. As the catalyst concentration is increased, the separation efficiency of the mini-hydrocyclone group gradually increased as well, from 74.8% to 82.6%. Furthermore, the fish hook phenomenon existed in the grade efficiency curve of the mini-hydrocyclone group. The cut size d(50) ranged from 1.78 mu m to 1.92 mu m, in good agreement with that for single mini-hydrocyclone. Results indicated that the mini-hydrocyclone group can meet the requirements of satisfying separation efficiency and smaller cut-size precision in industry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [1] Pressure drop and flow distribution in a mini-hydrocyclone group: UU-type parallel arrangement
    Huang, Cong
    Wang, Jian-gang
    Wang, Jun-ye
    Chen, Cong
    Wang, Hua-lin
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 103 : 139 - 150
  • [2] UU-type parallel mini-hydrocyclone group separation of fine particles from methanol-to-olefin industrial wastewater
    Lv, Wen-jie
    Chen, Jian-qi
    Chang, Yu-long
    Liu, Hong-lai
    Wang, Hua-lin
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2018, 131 : 34 - 42
  • [3] UU-type parallel mini-hydrocyclone group for oil-water separation in methanol-to-olefin industrial wastewater
    Lv, Wen-jie
    Dang, Zhi-hong
    He, Yuan
    Chang, Yu-long
    Ma, Shi-hao
    Liu, Bing
    Gao, Lian-xin
    Ma, Liang
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 149
  • [4] Experimental study of particle separation and the fishhook effect in a mini-hydrocyclone
    Zhu, Guofeng
    Liow, Jong-Leng
    [J]. CHEMICAL ENGINEERING SCIENCE, 2014, 111 : 94 - 105
  • [5] Computational study of the flow characteristics and separation efficiency in a mini-hydrocyclone
    Zhu, Guofeng
    Liow, Jong-Leng
    Neely, Andrew
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (12): : 2135 - 2147
  • [6] STUDY OF THE TRANSITIONAL FLOW AND PARTICLE SEPARATION WITH A FISHHOOK EFFECT IN A MINI-HYDROCYCLONE
    Zhu, Guofeng
    Liow, Jong-Leng
    Neely, Andrew
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, VOL 2: FORA, 2012, : 289 - 298
  • [7] Uniform distribution design and performance evaluation for UU-type parallel mini-hydrocyclones
    Huang, Cong
    Lv, Wen-jie
    Wang, Jian-gang
    Wang, Jun-ye
    Wang, Hua-lin
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2014, 125 : 194 - 201
  • [8] Flow distribution and pressure drop in UZ-type mini-hydrocyclone group arranged in compact parallel manifolds
    Chang, Yu-long
    Wang, Hua-lin
    Jin, Jue-hui
    Liu, Zhe-ming
    Lv, Wen-jie
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 100 : 114 - 123
  • [9] Modular mini-hydrocyclone desilter type of 30 mm: An experimental and optimization study
    Mognon, J. L.
    da Silva, J. M.
    Bicalho, I. C.
    Ataide, C. H.
    Duarte, C. R.
    [J]. JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2015, 129 : 145 - 152
  • [10] CFD study on separation enhancement of mini-hydrocyclone by particulate arrangement
    Yang, Qiang
    Lv, Wen-jie
    Ma, Liang
    Wang, Hua-lin
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 102 : 15 - 25