Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST

被引:8
|
作者
Yang, Li [1 ,2 ]
Cao, Hong-Rui [1 ]
Zhao, Jin-Long [1 ]
Zhang, Zi-Han [3 ]
Li, Qiang [1 ,2 ]
Wu, Guo-Bin [3 ]
Zhang, Yong-Qiang [1 ,2 ]
Zhong, Guo-Qiang [1 ]
Hu, Li-Qun [1 ]
Zhang, Zi-Jun [1 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Peoples R China
[3] Hefei Univ Technol, Hefei 230009, Peoples R China
关键词
EAST; Neutron flux monitoring; High time resolution; Wide range; Pulse signal acquisition and processing system;
D O I
10.1007/s41365-022-01016-y
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak (EAST). The measurement result of neutron flux monitoring (NFM) is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity. Therefore, a wide range and high time resolution are required for the NFM system on EAST. To satisfy these requirements, a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed. The present study was conducted using a field-programmable gate array (FPGA) and peripheral component interconnect extension for instrument express (PXIe) platform. The digital dual measurement modes, which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode, were designed to expand the measurement range of the signal acquisition and processing system. The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing high-speed analog-to-digital converters (ADCs), a high-speed PXIe communication with a direct memory access (DMA) mode, and online data preprocessing technology of FPGA. The signal acquisition and processing system was tested experimentally in the EAST radiation field. The test results showed that the time resolution of NFM was improved to 1 ms, and the dynamic range of the neutron counts rate was expanded to more than 10(6) counts per second. The Campbelling mode was calibrated using a multipoint average linear fitting method; subsequently, the fitting coefficient reached 0.9911. Therefore, the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
引用
收藏
页数:11
相关论文
共 24 条
  • [11] Development of a high-speed digital pulse signal acquisition and processing system based on MTCA for liquid scintillator neutron detector on EAST
    Yong-Qiang Zhang
    Li-Qun Hu
    Guo-Qiang Zhong
    Hong-Rui Cao
    Jin-Long Zhao
    Li Yang
    Qiang Li
    Nuclear Science and Techniques, 2023, 34
  • [12] Development of a high-speed digital pulse signal acquisition and processing system based on MTCA for liquid scintillator neutron detector on EAST
    Yong-Qiang Zhang
    Li-Qun Hu
    Guo-Qiang Zhong
    Hong-Rui Cao
    Jin-Long Zhao
    Li Yang
    Qiang Li
    NuclearScienceandTechniques, 2023, 34 (10) : 62 - 74
  • [13] Development of a Wide Dynamic Range Neutron Flux Measurement Instrument Having Fast Time Response for Fusion Experiments
    Ito, Daijiro
    Yazawa, Hiroyuki
    Tomitaka, Makoto
    Kumagai, Tsuyoshi
    Kono, Shigehiro
    Yamauchi, Michinori
    Misawa, Tsuyoshi
    Kobuchi, Takashi
    Hayashi, Hiroshi
    Miyake, Hitoshi
    Ogawa, Kunihiro
    Nishitani, Takeo
    Isobe, Mitsutaka
    PLASMA AND FUSION RESEARCH, 2021, 16 : 1 - 12
  • [14] WIDE-RANGE BIPOLAR PULSE CONDUCTANCE INSTRUMENT EMPLOYING CURRENT AND VOLTAGE MODES WITH SAMPLED OR INTEGRATED SIGNAL ACQUISITION
    CALHOUN, RK
    HOLLER, FJ
    GEIGER, RF
    NIEMAN, TA
    CASERTA, KJ
    ANALYTICA CHIMICA ACTA, 1991, 252 (1-2) : 29 - 40
  • [15] High-Temperature, Wide-Range, and Fast-Response Thin-Film Anemometer Based on Plasma of Glow Discharge
    Chen, Qinnan
    Wei, Hongcheng
    Liu, Xianlong
    Xu, Yi
    Li, Xin
    Zhang, Peng
    Hai, Zhenyin
    Wu, Dezhi
    Zhao, Yang
    Liu, Kun
    Sun, Daoheng
    IEEE SENSORS JOURNAL, 2023, 23 (17) : 19082 - 19091
  • [16] FPGA Based Wide Range Neutron Flux Monitoring System using Campbell Mode
    Alarcon, Juan
    Marzano, Leandro
    Thorp, Silvia
    Verrastro, Claudio
    2019 X SOUTHERN CONFERENCE ON PROGRAMMABLE LOGIC (SPL), 2019, : 77 - 81
  • [17] Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device
    Isobe, M.
    Ogawa, K.
    Miyake, H.
    Hayashi, H.
    Kobuchi, T.
    Nakano, Y.
    Watanabe, K.
    Uritani, A.
    Misawa, T.
    Nishitani, T.
    Tomitaka, M.
    Kumagai, T.
    Mashiyama, Y.
    Ito, D.
    Kono, S.
    Yamauchi, M.
    Takeiri, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [18] Development of a real-time digital pulse acquisition and processing algorithm for compact neutron spectrometer on EAST
    Zhang, Yong-Qiang
    Hu, Li-Qun
    Lu, Wei
    Zhong, Guo-Qiang
    Cao, Hong-Rui
    Zhao, Jin-Long
    Yang, Li
    Zhang, Rui-Xue
    Li, Qiang
    FUSION ENGINEERING AND DESIGN, 2024, 202
  • [19] Wide-dynamic-range, fast-response CBr4 doping system for molecular beam epitaxy
    Chang, Yu-Chia
    Zheng, Yan
    English, John H.
    Jackson, Andrew W.
    Coldren, Larry A.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (03):
  • [20] High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration
    Ren-Jie Zhu
    Xiang Zhou
    Zi-Hao Liu
    Wen-Di Wang
    Xiao-Li Mou
    Teng-Fei Fang
    Qing-Li Ma
    Xiu-Feng Xu
    Guo-Liang Yuan
    Li Zhao
    Ling-Feng Wei
    Ze-Jie Yin
    NuclearScienceandTechniques, 2020, 31 (09) : 100 - 108