3D strain imaging using a rectilinear 2D array

被引:8
|
作者
Awad, Samer I. [1 ]
Yen, Jesse T. [1 ]
机构
[1] Univ So Calif, Viterbi Sch Engn, Los Angeles, CA 90089 USA
关键词
2-D array; 3-D imaging; strain imaging; ultrasound;
D O I
10.1177/016173460702900403
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Under mechanical compression, tissue movements are inherently three-dimensional. 2-D, strain imaging can suffer from decorrelation noise caused by out-of-plane tissue movement in elevation. With 3-D strain imaging, all tissue movements can be estimated and compensated, hence minimizing out-of-plane decorrelation noise. Promising 3-D strain imaging results have been shown using 1-D arrays with mechanical translation in elevation. However, the relatively large slice thickness and mechanical translation can degrade image quality. Using 2-D arrays, an improved elevational resolution can be achieved with electronic focusing. Furthermore, scanning with 2-D arrays is also done electronically, which eliminates the need for mechanical translation. In this paper, we demonstrate the feasibility of 3-D strain imaging using a 4 cm x 4 cm ultrasonic sparse rectilinear 2-D array operating at 5MHz. The signal processing combinations of 2-D or 3-D beamforming followed by 2-D or 3-D strain imaging are studied and compared to each other to evaluate the performance of our 3-D strain imaging system. 3-D beamforming followed by 3-D strain imaging showed best performance in all experiments.
引用
收藏
页码:220 / 230
页数:11
相关论文
共 50 条
  • [1] 3-D strain imaging using a rectilinear 2D array
    Awad, Samer I.
    Yen, Jesse T.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 228 - 231
  • [2] 3D Passive Imaging of Ultrasound Cavitation using a 2D Array
    Boulos, Paul
    Varray, Francois
    Gilles, Bruno
    Bera, Jean-Christophe
    Cachard, Christian
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [3] Strain Imaging Using a Rectilinear 2-D Array: Preliminary Results
    Awad, Samer I.
    Lye, Yan Lin
    Yen, Jesse T.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1270 - 1273
  • [4] A spiral 2D phased array for 3D imaging
    Sumanaweera, TS
    Schwartz, J
    Napolitano, D
    [J]. 1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1271 - 1274
  • [5] Piezoelectric sectorial 2D array for 3D acoustical imaging
    Akhnak, M
    Martínez, O
    Gomez-Ullate, L
    de Espinosa, FM
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 85 (1-3) : 60 - 64
  • [6] Ultrasonic imaging of 3D displacement vectors using a simulated 2D array and beamsteering
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    [J]. ULTRASONICS, 2013, 53 (02) : 615 - 621
  • [7] 3D ultrasound coherence imaging based on 2D array design
    Jia, Yanping
    Xu, Mengling
    Ding, Mingyue
    Yuchi, Ming
    [J]. MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [8] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    [J]. JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [9] Rectilinear routing algorithm for crosstalk minimisation in 2D and 3D IC
    Mondal, Khokan
    Das, Subhajit
    Samanta, Tuhina
    [J]. IET COMPUTERS AND DIGITAL TECHNIQUES, 2020, 14 (06): : 263 - 271
  • [10] High frame rate 2D and 3D Imaging with a curved or cylindrical array
    Hu, P
    Lu, JY
    [J]. 2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1725 - 1728