Shear strengthening of RC beams with FRP grid-reinforced ECC matrix

被引:105
|
作者
Yang, Xu [1 ]
Gao, Wan-Yang [2 ,3 ]
Dai, Jian-Guo [4 ]
Lu, Zhou-Dao [5 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai 200240, Peoples R China
[4] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong 999077, Peoples R China
[5] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Reinforced concrete; Beam; Shear strengthening; Fiber-reinforced polymer (FRP) grid; Engineered cementitious composite (ECC); Digital image correlation (DIC) technique; CEMENTITIOUS COMPOSITES; CONCRETE MEMBERS; BOND BEHAVIOR; MORTAR TRM; T-BEAMS; CFRP; SHEETS; BASALT; JOINTS; PLATES;
D O I
10.1016/j.compstruct.2020.112120
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Fabric reinforced cementitious matrix (FRCM) composites are increasingly used for flexural and shear strengthening of reinforced concrete (RC) beams. This paper presents the results from an experimental study on the effectiveness and performance of a new FRCM system made of FRP grid-reinforced ECC matrix (referred to as "FGREM" for brevity) for shear strengthening of RC beams. A total of twelve shear-critical RC beams were constructed and tested. The parameters varied between the tests included the type of FRP grids, the type of cementitious matrix, the installation method of the shear strengthening system (prefabricated or cast-in-place), and the shear span-to-depth ratio of the beams. The crack patterns of all the tested beams were monitored using the digital image correlation (DIC) technique. Test results indicated that interfacial debonding of the shear strengthening layer and separation of the concrete side covers were two typical failure modes for the beams strengthened with the cast-in-place method and the prefabricated method, respectively. The gains in the shear capacity of the strengthened beams ranged from 50.9% to 160.6% with respect to the reference beams. Compared to the cast-in-place installation method, the prefabricated FGREM was demonstrated to be more efficient for shear strengthening of the RC beams.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Shear strengthening of RC beams with corrosion-damaged stirrups using FRP grid-reinforced ECC matrix composites
    Zheng, Aohan
    Li, Shan
    Zhang, Dengfeng
    Yan, Yuhong
    COMPOSITE STRUCTURES, 2021, 272
  • [2] Flexural strengthening of RC beams with CFRP grid-reinforced ECC matrix
    Yang, Xu
    Gao, Wan-Yang
    Dai, Jian-Guo
    Lu, Zhou-Dao
    Yu, Ke-Quan
    COMPOSITE STRUCTURES, 2018, 189 : 9 - 26
  • [3] Experimental investigation of corrosion-damaged RC beams strengthened in flexure with FRP grid-reinforced ECC matrix composites
    Zheng, Aohan
    Liu, Zhenzhen
    Li, Faping
    Li, Shan
    ENGINEERING STRUCTURES, 2021, 244
  • [4] Fatigue performance of corrosion-damaged beams strengthened with FRP grid-reinforced ECC matrix composites
    Zheng, Aohan
    Zong, Shuai
    Lu, Yiyan
    Li, Shan
    ENGINEERING STRUCTURES, 2022, 255
  • [5] Flexural behavior of the corroded RC beams strengthened with BFRP grid-reinforced ECC
    Zhang, Zaiyu
    Guo, Xiaoyang
    Yang, Zixuan
    Ji, Jundu
    Sun, Qing
    Tian, Penggang
    Wu, Xiaohong
    STRUCTURES, 2023, 58
  • [6] Analysis on flexural capacity of basalt textile grid-reinforced ECC strengthening RC beam
    Wang, Bo
    Liu, Gejia
    Zhang, Zhen
    Wang, Zicheng
    Han, Yufei
    STRUCTURAL CONCRETE, 2024,
  • [7] Shear strengthening of RC short columns with CFRP grid-reinforced FRC matrix: Cyclic loading tests
    Guo, Liying
    Deng, Mingke
    Li, Ruizhe
    Li, Tong
    Dong, Zhifang
    Journal of Building Engineering, 2022, 47
  • [8] Shear strengthening of RC short columns with CFRP grid-reinforced FRC matrix: Cyclic loading tests
    Guo, Liying
    Deng, Mingke
    Li, Ruizhe
    Li, Tong
    Dong, Zhifang
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [9] Experimental study on flexural shear strengthening effect on low-strength RC beams by using FRP grid and ECC
    Guo, Rui
    Ren, Yu
    Li, Mengqi
    Hu, Peng
    Du, Min
    Zhang, Rui
    ENGINEERING STRUCTURES, 2021, 227
  • [10] Experimental study on flexural shear strengthening effect on low-strength RC beams by using FRP grid and ECC
    Guo, Rui
    Ren, Yu
    Li, Mengqi
    Hu, Peng
    Du, Min
    Zhang, Rui
    Engineering Structures, 2021, 227