Ambulant ECG Recording with Wet and Dry Electrodes: A Direct Comparison of two Systems

被引:0
|
作者
Fuhrhop, S. [1 ]
Lamparth, S. [1 ]
Kirst, M. [2 ]
v. Wagner, G. [3 ]
Ottenbacher, J. [1 ]
机构
[1] Univ Karlsruhe, ITIV, Vincenz Priessnitz Str 1, D-76131 Karlsruhe, Germany
[2] FZI Forschungszentrum Informat, Karlsruhe, Germany
[3] Metrax GmbH, Rottweil, Germany
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5 | 2009年 / 25卷
关键词
ECG; Holter; benchmark; dry electrodes; care.mon;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Long-term ECG monitoring has established itself as a standard cardiologic diagnostic method since it allows the detection of rare occurring arrhythmias. Conventional Holter recorders that use wet electrodes have however proven to have the restriction of limited application periods and poor wearing-comfort. Recent approaches have focused to benefiting from the extended durability of dry electrodes and modern smart textile technologies with a view to achieving convenient wearing comfort. In this paper the performance of a newly developed ECG monitoring system with dry electrodes is evaluated. An ECG has been recorded on a dry electrode system and simultaneously on the usual Holter device. The QRS detection performance results have then been compared against each other. Both well-defined short-time measurements on a bicycle ergometer and real-life long-time measurements were taken. The acquisition of a consistent good signal quality however remains a big challenge in a real-life scenario, notwithstanding the fact that no significant difference was observed from the first scenario.
引用
收藏
页码:305 / +
页数:2
相关论文
共 50 条
  • [1] A direct comparison of wet, dry and insulating bioelectric recording electrodes
    Searle, A
    Kirkup, L
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) : 271 - 283
  • [2] Electrical Characterisation of Dry Electrodes for ECG Recording
    Baba, A.
    Burke, M. J.
    PROCEEDINGS OF THE 12TH WSEAS INTERNATIONAL CONFERENCE ON CIRCUITS: NEW ASPECTS OF CIRCUITS, 2008, : 76 - +
  • [3] Characterization of Single Lead Continuous ECG Recording with Various Dry Electrodes
    ul Hassan, Muhammad Faiz
    Lai, Dakun
    Bu, Yuxiang
    ICCBB 2019: PROCEEDINGS OF THE 2019 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2019, : 76 - 79
  • [4] Noise performance of textile-based dry ECG recording electrodes
    Maji, Soumyajyoti
    Burke, Martin J.
    ELECTRONICS LETTERS, 2021, 57 (02) : 45 - 48
  • [5] Skin-Potential Variation Insensitive Dry Electrodes for ECG Recording
    Pei, Weihua
    Zhang, He
    Wang, Yijun
    Guo, Xuhong
    Xing, Xiao
    Huang, Yong
    Xie, Yuxing
    Yang, Xiaowei
    Chen, Hongda
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) : 463 - 470
  • [6] ELECTRONIC WET AND DRY, DIRECT AND DIFFERENTIAL RECORDING THERMOMETER.
    Banerjee, S.
    Bhave, V.R.
    Navaneeth, G.N.
    Indian Journal of Environmental Health, 1980, 22 (01) : 93 - 95
  • [7] A DIRECT COMPARISON OF THE WET AND DRY FLOTATION ENVIRONMENTS
    FORGAYS, DG
    FORGAYS, DK
    PUDVAH, M
    WRIGHT, D
    JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 1991, 11 (02) : 179 - 187
  • [8] Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
    Chen, Yun-Hsuan
    Op de Beeck, Maaike
    Vanderheyden, Luc
    Carrette, Evelien
    Mihajlovic, Vojkan
    Vanstreels, Kris
    Grundlehner, Bernard
    Gadeyne, Stefanie
    Boon, Paul
    Van Hoof, Chris
    SENSORS, 2014, 14 (12): : 23758 - 23780
  • [9] Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
    Ottenbacher, Joerg
    Kirst, Malte
    Jatoba, Luciana
    Huflejt, Michal
    Grossmann, Ulrich
    Stork, Wilhelm
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1695 - +
  • [10] Contact ECG Recording Using Copper and E-Textile Based Flexible Dry Electrodes
    Ren, Kai
    Ma, Ruyu
    Nikkhah, Mohammad R.
    Eggleston, Steve
    Ren, Yu-Jiun
    Behdad, Nader
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 47 - 58