Computer-assisted surgery in total knee replacement preliminary results: Report of 60 cases

被引:3
|
作者
El Masri, F. [1 ]
Rammal, H. [1 ]
Ghanem, I. [1 ]
El Hage, S. [1 ]
El Abiad, R. [1 ]
Kharrat, K. [1 ]
Dagher, F. [1 ]
机构
[1] Univ St Joseph, Hop Hotel Dieu de France, Beirut, Lebanon
关键词
total knee replacement; computer-assisted surgery;
D O I
10.1016/j.rco.2007.10.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study. -Conventional techniques proposed for total knee arthroplasty (TKA), necessarily require an acceptable alignment of the Lower Limb. Computer-assisted surgery is becoming increasingly popular in order to improve the precision of the component alignment, an essential element for good tong-term results. The purpose of this prospective study was to present our preliminary results with computer-assisted implantation of TKA. Material and methods. -This was a prospective study of 55 patients (60 knees) included at random for computer-assisted TKA between April 2004 and September 2005. Mean age was 70.5 years. The preoperative assessment noted genu varum in 56 knees and genu valgum in four knees. Three knees with unilateral degenerative disease presented a post traumatic tibia malunion. The same surgeon performed all of the operations using the same prosthesis and navigation system (P.FC.((R)) Sigma (TM)). Lower limb alignment and orientation of the prosthetic implants were assessed with standard pre- and postoperative gonometry. Sagittal alignment was measured on the standard X-rays (Lateral and anteroposterior view). Results. -Knee alignment improved from 8.1 +/- 4.5 degrees varus (10 degrees valgus to 18 degrees varus) preoperatively, to 0.4 +/- 0.6 degrees varus (1 degrees vaigus to 2 degrees varus) postoperatively. In the frontal plane, the mean angle of the femoral component on the anteroposterior (ap) view was 89.7 +/- 0.7 degrees (88-91 degrees). The mean angle of the tibial component on the ap view was 89.9 +/- 0.7 degrees (88.5-91 degrees). The femorotibial mechanical axis was within +/- 2 degrees for all. prostheses. In the sagittal plane, the mean angle of the femoral. component on the lateral view was 4.8 degrees (3-6.5 degrees). The mean tibial. slope was 2.7 degrees (1-4 degrees) for the prostheses with a fixed tibial plateau and 0.2 degrees (-1 degrees to +1 degrees) for those with a rotating plateau. The mean operative time was 135 min (110-180 min) and was inversely proportional to experience. There was one conversion to conventional surgery due to software dysfunction. There were no complications related to the operative technique. Discussion. -The best outcome, particularly in terms of aseptic loosening, is reported for knees with a vaigus or varus angle within 3 degrees. The improved accuracy of computer-assisted implantation has enabled better orientation of the components in the frontal, sagittal and horizontal planes with implantations well within this range.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [41] Computer-assisted surgery for knee ligament reconstruction
    Eggerding, Vincent
    Reijman, Max
    Scholten, Rob J. P. M.
    Verhaar, Jan A. N.
    Meuffels, Duncan E.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (09):
  • [42] Relationship between cutting errors and learning curve in computer-assisted total knee replacement
    Manzotti, Alfonso
    Cerveri, Pietro
    De Momi, Elena
    Pullen, Chris
    Confalonieri, Norberto
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (05) : 655 - 662
  • [43] Computer-Assisted Surgery for Knee Ligament Reconstruction
    Andrews, Lesley
    ORTHOPAEDIC NURSING, 2015, 34 (06) : 375 - 376
  • [44] Computer-assisted surgery for knee ligament reconstruction
    Eggerding, Vincent
    Reijman, Max
    Scholten, Rob J. P. M.
    Meuffels, Duncan E.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (08):
  • [45] When computer-assisted knee replacement is the best alternative
    Fehring, Thomas K.
    Mason, J. Bohannon
    Moskal, Joseph
    Pollock, David C.
    Mann, John
    Williams, Vincent J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 132 - 136
  • [46] Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique
    F. Conteduca
    F. Massai
    R. Iorio
    E. Zanzotto
    D. Luzon
    A. Ferretti
    International Orthopaedics, 2009, 33 : 1609 - 1613
  • [47] Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique
    Conteduca, F.
    Massai, F.
    Iorio, R.
    Zanzotto, E.
    Luzon, D.
    Ferretti, A.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) : 1609 - 1613
  • [48] Computer-assisted total knee replacement after medial opening wedge high tibial osteotomy: medium-term results in a series of ninety cases
    Saragaglia, Dominique
    Massfelder, Julie
    Refaie, Ramsay
    Rubens-Duval, Brice
    Mader, Roch
    Rouchy, Rene Christopher
    Pailhe, Regis
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 35 - 40
  • [49] Computer-assisted total knee replacement after medial opening wedge high tibial osteotomy: medium-term results in a series of ninety cases
    Dominique Saragaglia
    Julie Massfelder
    Ramsay Refaie
    Brice Rubens-Duval
    Roch Mader
    René Christopher Rouchy
    Régis Pailhé
    International Orthopaedics, 2016, 40 : 35 - 40
  • [50] A Randomized Controlled Study to Compare the Total and Hidden Blood Loss in Computer-Assisted Surgery and Conventional Surgical Technique of Total Knee Replacement
    Singla, Amit
    Malhotra, Rajesh
    Kumar, Vijay
    Lekha, Chandra
    Karthikeyan, G.
    Malik, Vishwas
    CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (02) : 211 - 216