Excitation module for orthogonal fundamental mode fluxgate sensor

被引:5
|
作者
Song, S. X. [1 ]
Deng, M. [1 ]
Chen, K. [1 ]
Yuan, Z. Z. [3 ]
Xu, Z. F. [2 ]
Zhang, Q. S. [1 ]
机构
[1] China Univ Geosci Beijing, Sch Geophys & Informat Technol, Beijing, Peoples R China
[2] Beijing Huahang Radio Measurement Inst, Beijing, Peoples R China
[3] China Key Syst & Integrated Circuit Co Ltd, Wuxi, Jiangsu, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2020年 / 15卷 / 05期
关键词
Analogue electronic circuits; Modular electronics; Front-end electronics for detector readout; NOISE; MECHANISM; WIRE;
D O I
10.1088/1748-0221/15/05/P05007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fluxgate is a device that has important applications in weak magnetic field measurements. Compared with the second harmonic mode, the orthogonal fundamental mode fluxgate exhibits a better performance in terms of lower noise and wider bandwidth, making it popular among researchers in this field. An amorphous wire is a vital part of any orthogonal fundamental mode fluxgate, and its excitation parameters determine the performance of the sensor (especially the noise level). For different structures and sizes of amorphous wires as probes, the optimal excitation parameters of orthogonal fundamental mode fluxgate are different. The conventional excitation module development scheme suffers from problems such as a complicated structure and low flexibility. To overcome these problems, a simple, compact, and effective excitation module is proposed, which is composed of a waveform generator, signal conditioning circuit, and voltage-controlled current source. Owing to the high flexibility, the frequency of the direct digital frequency synthesis is fully programmable. We tested the design performance indexes of key parameters, such as excitation signal waveform, amplitude, noise level, and bandwidth. The excitation current noise level is as low as 12.42 nA/sqrt (Hz)@ 20 kHz without I-ac and 17.35 nA/sqrt (Hz)@ 20 kHz with I-ac. The effective bandwidth of the alternating current output is 10-200 kHz. Moreover, a system test platform was developed, and this module was used to analyze the variation trend of the noise level of the fluxgate sensor under different excitation parameters (such as I-ac, I-dc, and excitation current frequency). It has been proved that the excitation module helps in effectively and quickly selecting the best excitation parameters to improve the performance of orthogonal fundamental mode fluxgates and shorten their development cycle.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Superparamagnetic nanoparticle detection system by using a fundamental mode orthogonal fluxgate (FM-OFG) gradiometer
    Karo, Hikaru
    Sasada, Ichiro
    AIP ADVANCES, 2017, 7 (05):
  • [32] Low-Noise Fundamental-Mode Orthogonal Fluxgate Magnetometer Built With an Amorphous Ribbon Core
    Sasada, Ichiro
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [33] Influences of Operation Frequency and Excitation Current on Output Signal of Orthogonal Fluxgate Sensor Fabricated with an Amorphous Wire
    Shin, Kwang-Ho
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2009, 19 (01): : 17 - 21
  • [34] Excitation and temperature stability, of PCB fluxgate sensor
    Tipek, A
    O'Donnell, T
    Ripka, P
    Kubik, J
    IEEE SENSORS JOURNAL, 2005, 5 (06) : 1264 - 1269
  • [35] Reduction of magnetic noise limits of orthogonal fluxgate sensor
    Dressler, Michal
    Janosek, Michal
    Butta, Mattia
    AIP ADVANCES, 2021, 11 (01)
  • [36] Development of a high-sensitivity orthogonal fluxgate sensor
    Priftis, Panagiotis
    Angelopoulos, Spyridon
    Ktena, Aphrodite
    Hristoforou, Evangelos
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2024, 590
  • [37] Low noise fundamental mode orthogonal fluxgate (FM-OFG) magnetometer built with an amorphous ribbon core
    Sasada, I.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [38] Integrated driving and readout circuits for orthogonal fluxgate sensor
    Qian, XB
    Li, XP
    Xu, YP
    Fan, J
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) : 3715 - 3717
  • [39] Practical Method for Drastic Improvement of Output Offset Stability in Bias-Switched Fundamental Mode Orthogonal Fluxgate
    Murata, Naofumi
    Matsuoka, Ayako
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18641 - 18649
  • [40] Fluxgate sensor measurements in the deterministic chaos mode
    Korotkii, V. P.
    Ilyin, V. N.
    MEASUREMENT TECHNIQUES, 2012, 55 (09) : 1077 - 1082