Voltammetric determination of cefpirome at multiwalled carbon nanotube modified glassy carbon sensor based electrode in bulk form and pharmaceutical formulation

被引:28
|
作者
Jain, Rajeev [1 ]
Vikas [1 ]
机构
[1] Jiwaji Univ, Sch Studies Chem, Gwalior 474011, India
关键词
Cefpirome (CEF); Multi-walled carbon nanotube modified glassy carbon electrode (MWCNT/GC); Pharmaceutical formulation; Sensor; ACID; DOPAMINE;
D O I
10.1016/j.colsurfb.2011.06.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new, simple and low cost voltammetric method for the determination of cefpirome in pharmaceutical preparations has been developed using multiwalled carbon nanotube modified glassy carbon electrode (MWCNT), which showed stable response with enhanced selectivity and sensitivity over the bare glassy carbon electrode. A multiwalled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) is used for the simultaneous determination of cefpirome by differential pulse voltammetry and square wave voltammetry. Results indicated that cathodic peak of cefpirome is greatly improved at MWCNT modified GC electrode as compared with the bare GC electrode showing excellent electrocatalytic activity towards cefpirome reduction. Linear calibration curves are obtained over the concentration range 100-600 mu gmL(-1) in Britton Robinson buffer at pH 4.51 with limit of detection (LOD) and limit of quantification (LOQ) are 0.647 mu gmL(-1) and 2.159 mu g mL(-1) using SWV and 5.540 mu g mL(-1) and 18.489 mu g mL(-1) using DPV, respectively. The described method is rapid and can be successfully applied for the determination of cefpirome in bulk form and pharmaceutical formulations. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:423 / 426
页数:4
相关论文
共 50 条
  • [21] Electrochemical sensor using glassy carbon electrode modified with acylpyrazolone-multiwalled carbon nanotube composite film for determination of xanthine
    Yun Song
    Jinzhou Li
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 689 - 695
  • [22] A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite as a New Sensor for Simultaneous Determination of Acetaminophen and Mefenamic Acid in Pharmaceutical Preparations and Biological Samples
    Babaei, Ali
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    [J]. ELECTROANALYSIS, 2010, 22 (15) : 1743 - 1749
  • [23] Square Wave Voltammetric Determination of Dexamethasone on a Multiwalled Carbon Nanotube Modified Pencil Electrode
    Rezaei, B.
    Zare, S. Z. Mirahmadi
    Ensafi, Ali A.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (05) : 897 - 904
  • [24] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    [J]. ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [25] Voltammetric determination of promethazine hydrochloride at a multi-wall carbon nanotube modified glassy carbon electrode
    Xi, Xia
    Ming, Liang
    Liu, Jie
    [J]. DRUG TESTING AND ANALYSIS, 2011, 3 (03) : 182 - 186
  • [26] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [27] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [28] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    [J]. Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [29] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [30] Amperometric glucose sensor based on glucose oxidase immobilized on gelatin-multiwalled carbon nanotube modified glassy carbon electrode
    Periasamy, Arun Prakash
    Chang, Yu-Jung
    Chen, Shen-Ming
    [J]. BIOELECTROCHEMISTRY, 2011, 80 (02) : 114 - 120