A robotic device for measuring and controlling pelvic motion during locomotor rehabilitation

被引:26
|
作者
Ichinose, WE [1 ]
Reinkensmeyer, DJ [1 ]
Aoyagi, D [1 ]
Lin, JT [1 ]
Ngai, K [1 ]
Edgerton, VR [1 ]
Harkema, SJ [1 ]
Bobrow, JE [1 ]
机构
[1] Univ Calif Irvine, Dept Mech & Aerosp Engn, Irvine, CA 92717 USA
关键词
locomotion; rehabilitation; robotics;
D O I
10.1109/IEMBS.2003.1279715
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper describes a robotic device for measuring and manipulating pelvic motion during step training on a treadmill. "PAM" (Pelvic Assist Manipulator) uses two, three-degree-of-freedom, pneumatic robots to measure and control the pelvis of a person during body weight supported stepping on a treadmill. The device can be used in a passive mode to record pelvic trajectories, either specified manually by a therapist or pre-recorded from unimpaired subjects, then replay these trajectories using a non-linear force control algorithm. Data are presented that demonstrate the ability of the device to record and replay the pelvic motions that occur during normal walking.
引用
收藏
页码:1690 / 1693
页数:4
相关论文
共 50 条
  • [31] Design Issues for an Inherently Safe Robotic Rehabilitation Device
    Carbone, Giuseppe
    Gherman, Bogdan
    Ulinici, Ionut
    Vaida, Calin
    Pisla, Doina
    ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, 2018, 49 : 1025 - 1032
  • [32] Minimizing Human Tracking Error for Robotic Rehabilitation Device
    Homich, Andrew J.
    Doerzbacher, Megan A.
    Tschantz, Eric L.
    Piazza, Stephen J.
    Hills, Everett C.
    Moore, Jason Z.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (04):
  • [33] A Novel Robotic Assistive Device for Stroke-Rehabilitation
    McConnell, Alistair
    Kong, Xianwen
    Vargas, Patricia A.
    2014 23RD IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (IEEE RO-MAN), 2014, : 917 - 923
  • [34] Dynamic motion planning for the design of robotic gait rehabilitation
    Wang, CYE
    Bobrow, JE
    Reinkensmeyer, DJ
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04): : 672 - 679
  • [35] Controlling the human-robot interaction for robotic rehabilitation of locomotion
    Jezernik, S
    Morari, M
    7TH INTERNATIONAL WORKSHOP ON ADVANCED MOTION CONTROL, PROCEEDINGS, 2002, : 133 - 135
  • [36] CONTINUOUS PASSIVE MOTION DEVICE FOR HAND REHABILITATION
    BENTHAM, JS
    BRERETON, WDS
    COCHRANE, IW
    LYTTLE, D
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1987, 68 (04): : 248 - 250
  • [37] Randomized Trial of a Robotic Assistive Device for the Upper Extremity During Early Inpatient Stroke Rehabilitation
    Masiero, Stefano
    Armani, Mario
    Ferlini, Gregorio
    Rosati, Giulio
    Rossi, Aldo
    NEUROREHABILITATION AND NEURAL REPAIR, 2014, 28 (04) : 377 - 386
  • [38] Evaluation of robotic-assisted locomotor training outcomes at a rehabilitation centre in Singapore
    Chin, L. F.
    Lim, W. S.
    Kong, K. H.
    SINGAPORE MEDICAL JOURNAL, 2010, 51 (09) : 709 - 715
  • [39] BIOMECHANICAL ROLE OF THE LOCOMOTOR SYSTEM IN CONTROLLING BODY CENTER OF MASS MOTION IN OLDER ADULTS DURING OBSTRUCTED GAIT
    Wang, T. -M.
    Chen, H. -L.
    Hsu, W. -C.
    Liu, M. -W.
    Lu, T. -W.
    JOURNAL OF MECHANICS, 2010, 26 (02) : 195 - 203
  • [40] Motion control of a robotic puppet through a hybrid motion capture device
    Nguyen, Kim Doang
    Chen, I-Ming
    Yeo, Song Huat
    Duh, Been-Lirn
    2007 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING, VOLS 1-3, 2007, : 760 - 765