UTE T2*mapping of tendinopathic patellar tendons: an MRI reproducibility study

被引:13
|
作者
Agergaard, Anne-Sofie [1 ,2 ,3 ]
Malmgaard-Clausen, Nikolaj M. [1 ,2 ]
Svensson, Rene B. [1 ,2 ]
Nybing, Janus D. [4 ]
Boesen, Mikael [4 ,5 ]
Kjaer, Michael [1 ,2 ]
Magnusson, S. Peter [1 ,2 ]
Hansen, Philip [4 ]
机构
[1] Bispebjerg & Frederiksberg Hosp, Inst Sports Med Copenhagen, Dept Orthoped Surg, Copenhagen, Denmark
[2] Univ Copenhagen, Fac Hlth Sci, Ctr Hlth Aging, Copenhagen, Denmark
[3] Bispebjerg & Frederiksberg Hosp, Dept Phys & Occupat Therapy, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Dept Radiol, Copenhagen, Denmark
[5] Bispebjerg & Frederiksberg Hosp, Parker Inst, Copenhagen, Denmark
关键词
Patellar tendon; tendinopathy; ultra-short echo time imaging; T2*mapping; reproducibility; MAGNETIC-RESONANCE; ACHILLES-TENDON; IN-VIVO; HEALTHY; T1; T-2-ASTERISK; RELIABILITY; TIMES;
D O I
10.1177/0284185120918807
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown. Purpose To evaluate test-retest reproducibility of UTE MRI T2* mapping of tendinopathic patellar tendons and to evaluate the intra- and inter-observer reproducibility of the measurement. Material and Methods Fifteen patients with chronic patellar tendinopathy were evaluated with UTE MRI twice in a 3.0-T scanner on the same day. Manual segmentation of the patellar tendon was performed by two blinded investigators and automated T2*map reconstruction was performed in custom-made software. Results There was a significant and numerically small difference in test-retest T2* values (T2*mean(diff) = 0.06 +/- 0.07 ms approximate to 3.7%; P = 0.006) with an ICC = 0.91 (95% confidence interval [CI] 0.58-0.98; typical error of 3.0%). The intra- and inter-observer reproducibility showed no significant bias (P = 0.493 and P = 0.052), and generally substantial reproducibility was demonstrated for T2* (intra-observer ICC = 0.99; 95% CI 0.98-1.00 and inter-observer ICC = 0.99; 95% CI 0.96-1.00, and typical error 1.3% and 1.3%, respectively). Conclusion These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [21] MRI study of transient cerebral ischemia in the gerbil -: Interest of T2 mapping
    Messager, T
    Franconi, F
    Lemaire, L
    De Bray, JM
    André, JPS
    Jallet, P
    Le Jeune, JJ
    INVESTIGATIVE RADIOLOGY, 2000, 35 (03) : 180 - 185
  • [22] Precision and reproducibility of T2 quantifications in myocardial T2 mapping: impact of the number of echoes and reconstruction model
    Tamer Basha
    Mehmet Akcakaya
    Sébastien Roujol
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [23] Reproducibility of slice-interleaved myocardial T2 mapping sequences
    Steven Bellm
    Tamer Basha
    Long Ngo
    Sophie Berg
    Kraig V Kissinger
    Beth Goddu
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [24] T2 mapping of healthy knee cartilage: multicenter multivendor reproducibility
    Verschueren, Joost
    Eijgenraam, Susanne M.
    Klein, Stefan
    Poot, Dirk H. J.
    Bierma-Zeinstra, Sita M. A.
    Tamames, Juan A. Hernandez
    Wielopolski, Piotr A.
    Reijman, Max
    Oei, Edwin H. G.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (04) : 1247 - 1255
  • [25] MRI of Splenic Sarcoidosis with T1 and T2 Mapping
    Camastra, Giovanni
    Ciolina, Federica
    RADIOLOGY, 2024, 310 (02)
  • [26] REPRODUCIBILITY OF T1 AND T2 MAPPING IN HEALTH AND DISEASE, AND ASSESSMENT OF T2 VARIABILITY ACROSS THE NORMAL MYOCARDIUM
    Puntmann, Valentina
    Foote, Lucy
    Baydes, Rocio Hinojar
    Higgins, David
    Nagel, Eike
    HEART, 2014, 100 : A76 - A76
  • [27] Analysis of Cardiac MRI With T2 Mapping in Cardiac Sarcoidosis
    Dennis, D. J.
    Chamberlin, J. H.
    Burt, J.
    Rieter, W. J.
    Kabakus, I. M.
    Fullenkamp, A.
    Dorsey, N. Stringer
    Van Swol, E.
    Paladugu, N.
    Houston, B.
    James, W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [28] Editorial for "Association Between T2*Relaxation Times Derived from Ultrashort Echo Time (UTE) MRI and Symptoms During Exercise Therapy for Patellar Tendinopathy: A Large Prospective Study"
    Wu, Mei
    Chung, Christine B.
    Du, Jiang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (05) : 1606 - 1607
  • [29] Pre- and postcontrast T1 and T2 mapping of patellar cartilage in young adults with recurrent patellar dislocation
    Mostroem, Eva Bengtsson
    Lammentausta, Eveliina
    Finnbogason, Throestur
    Weidenhielm, Lars
    Janarv, Per-Mats
    Tiderius, Carl Johan
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1363 - 1369
  • [30] Follow up of the rat patellar cartilage repair after polysaccharidic biomaterials implantation using MRI T2 mapping.
    Cheli, Y
    Watrin, A
    Ruaud, JP
    Olivier, P
    Etienne, S
    Gonord, P
    Payan, E
    Netter, P
    Gillet, P
    Loeuille, D
    ARTHRITIS AND RHEUMATISM, 2002, 46 (09): : S491 - S491