UTE T2*mapping of tendinopathic patellar tendons: an MRI reproducibility study

被引:13
|
作者
Agergaard, Anne-Sofie [1 ,2 ,3 ]
Malmgaard-Clausen, Nikolaj M. [1 ,2 ]
Svensson, Rene B. [1 ,2 ]
Nybing, Janus D. [4 ]
Boesen, Mikael [4 ,5 ]
Kjaer, Michael [1 ,2 ]
Magnusson, S. Peter [1 ,2 ]
Hansen, Philip [4 ]
机构
[1] Bispebjerg & Frederiksberg Hosp, Inst Sports Med Copenhagen, Dept Orthoped Surg, Copenhagen, Denmark
[2] Univ Copenhagen, Fac Hlth Sci, Ctr Hlth Aging, Copenhagen, Denmark
[3] Bispebjerg & Frederiksberg Hosp, Dept Phys & Occupat Therapy, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Dept Radiol, Copenhagen, Denmark
[5] Bispebjerg & Frederiksberg Hosp, Parker Inst, Copenhagen, Denmark
关键词
Patellar tendon; tendinopathy; ultra-short echo time imaging; T2*mapping; reproducibility; MAGNETIC-RESONANCE; ACHILLES-TENDON; IN-VIVO; HEALTHY; T1; T-2-ASTERISK; RELIABILITY; TIMES;
D O I
10.1177/0284185120918807
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown. Purpose To evaluate test-retest reproducibility of UTE MRI T2* mapping of tendinopathic patellar tendons and to evaluate the intra- and inter-observer reproducibility of the measurement. Material and Methods Fifteen patients with chronic patellar tendinopathy were evaluated with UTE MRI twice in a 3.0-T scanner on the same day. Manual segmentation of the patellar tendon was performed by two blinded investigators and automated T2*map reconstruction was performed in custom-made software. Results There was a significant and numerically small difference in test-retest T2* values (T2*mean(diff) = 0.06 +/- 0.07 ms approximate to 3.7%; P = 0.006) with an ICC = 0.91 (95% confidence interval [CI] 0.58-0.98; typical error of 3.0%). The intra- and inter-observer reproducibility showed no significant bias (P = 0.493 and P = 0.052), and generally substantial reproducibility was demonstrated for T2* (intra-observer ICC = 0.99; 95% CI 0.98-1.00 and inter-observer ICC = 0.99; 95% CI 0.96-1.00, and typical error 1.3% and 1.3%, respectively). Conclusion These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [1] T2 mapping in patellar chondromalacia
    Ruiz Santiago, Fernando
    Pozuelo Calvo, Rocio
    Almansa Lopez, Julio
    Guzman Alvarez, Luis
    Castellano Garcia, Maria del Mar
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) : 984 - 988
  • [2] T2 mapping of rat patellar cartilage
    Watrin, A
    Ruaud, JPB
    Olivier, PTA
    Guingamp, NC
    Gonord, PD
    Netter, PA
    Blum, AG
    Guillot, GM
    Gillet, PM
    Loeuille, DHJ
    RADIOLOGY, 2001, 219 (02) : 395 - 402
  • [3] Reproducibility of T2* mapping in the human cerebral cortex in vivo at 7 tesla MRI
    Govindarajan, Sindhuja T.
    Cohen-Adad, Julien
    Sormani, Maria Pia
    Fan, Audrey P.
    Louapre, Celine
    Mainero, Caterina
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 290 - 296
  • [4] Impact of undersampling on preclinical lung T2* mapping with 3D radial UTE MRI at 7 T
    Stecker, Ian R.
    Bdaiwi, Abdullah S.
    Niedbalski, Peter J.
    Chatterjee, Neelakshi
    Hossain, Md M.
    Cleveland, Zackary I.
    JOURNAL OF MAGNETIC RESONANCE, 2024, 365
  • [5] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [6] Reproducibility and repeatability of quantitative T2 and T2*mapping of osteosarcomas in a mouse model
    Roudi, Raheleh
    Pisani, Laura J.
    Pisani, Fabrizio
    Liang, Tie
    Daldrup-Link, Heike E.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [7] Feasibility of ultrashort echo time (UTE) T2*cartilage mapping in the hip: a pilot study
    Wong, Tony T.
    Quarterman, Patrick
    Lynch, Thomas S.
    Rasiej, Michael J.
    Jaramillo, Diego
    Jambawalikar, Sachin R.
    ACTA RADIOLOGICA, 2022, 63 (06) : 760 - 766
  • [8] Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping
    Surowiec, Rachel K.
    Lucas, Erin P.
    Ho, Charles P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (06) : 1385 - 1395
  • [9] Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping
    Rachel K. Surowiec
    Erin P. Lucas
    Charles P. Ho
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1385 - 1395
  • [10] T1 and T2* mapping of the human quadriceps and patellar tendons using ultra-short echo-time (UTE) imaging and bivariate relaxation parameter-based volumetric visualization
    Kraemer, M.
    Maggioni, M. B.
    Brisson, N. M.
    Zachow, S.
    Teichgraeber, U.
    Duda, G. N.
    Reichenbach, J. R.
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 29 - 36